• 제목/요약/키워드: Photo Detector

검색결과 196건 처리시간 0.029초

선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가 (Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

위상평균 PTV 기법을 이용한 축류 홴 주위 유동의 속도장 측정 연구 (Velocity Field Measurement of Flow Around an Axial Fan Using a Phase Averaged 2-Frame PTV Technique)

  • 최제호;김형범;이상준;이인섭
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.114-123
    • /
    • 2000
  • The flow structure around a rotating axial-fan was experimentally investigated using a phase averaging velocity field measurement technique. The fan blades were divided into 4 different phases, for which 500 velocity fields were acquired for each phase angle with a 2-frame PTV system. Velocity field measurements were also carried out at two planes parallel to the axis of rotation, with offsets toward the radial direction of the fan. For accurate synchronization of the PTV system with the phase of the axial fan, two synchronization circuits were employed with a photo-detector attached to the rotating shaft. The phase averaged velocity fields show periodic variations with respect to the blade phase. The periodic formation of vortices at the blade tip is also observed in vorticity contour plots. Locations of local maximum turbulence intensities in the axial and radial directions are found to be located in an alternating pattern. These experimental results can be used to validate numerical calculations and to understand the flow characteristics of an axial fan.

비정질 셀레늄의 박막 제조공정에 따른 미세구조와 IV특성 (The X-ray Detection and morphology Characteristics on Evaporation Temperature of amorphous Selenium based digital X-ray detector)

  • 공현기;차병열;이규홍;김재형;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.51-54
    • /
    • 2002
  • Recently, due to its better photosensitivity in X-ray, the amorphous selenium based photoreceptor is used on digital direct method conversion material. Compared to other photoconductive material, amorphous selenium has good X-ray response characteristic and low leakage current. It has many parameters of detecting X-ray response on selenium. Among of them, it is well known that manufacture of a-Se is the most basic element. In this paper, we fabricated two types of amorphous selenium sample which had time variable. The one was fabricated continuous deposition sample and the other was step by step sample. Thickness of sample was $300{\mu}m$ and top electrode was evaporated gold. We investigated the leakage current and photo current of them and analysed their electrical characteristics. For analyzing morphology of samples, SEM and surface was pictured. We found that step by step deposition method could be applied for novel fabricating amorphous selenium film.

  • PDF

Development, Validation, and Application of a Portable SPR Biosensor for the Direct Detection of Insecticide Residues

  • Yang, Gil-Mo;Cho, Nam-Hong
    • Food Science and Biotechnology
    • /
    • 제17권5호
    • /
    • pp.1038-1046
    • /
    • 2008
  • This study was carried out to develop a small-sized biosensor based on surface plasmon resonance (SPR) for the rapid identification of insecticide residues for food safety. The SPR biosensor module consists of a single 770 nm-light emitting diodes (LED) light source, several optical lenses for transferring light, a hemisphere sensor chip, photo detector, A/D converter, power source, and software for signal processing using a computer. Except for the computer, the size and weight of the sensor module are 150 (L)$\times$70 (W)$\times$120 (H) mm and 828 g, respectively. Validation and application procedures were designed to assess refractive index analysis, affinity properties, sensitivity, linearity, limits of detection, and robustness which includes an analysis of baseline stability and reproducibility of ligand immobilization using carbamate (carbofuran and carbaryl) and organophosphate (cadusafos, ethoprofos, and chlorpyrifos) insecticide residues. With direct binding analysis, insecticide residues were detected at less than the minimum 0.01 ppm and analyzed in less than 100 sec with a good linear relationship. Based on these results, we find that the binding interaction with active target groups in enzymes using the miniaturized SPR biosensor could detect low concentrations which satisfy the maximum residue limits for pesticide tolerance in Korea, Japan, and the USA.

배연가스의 $NO_x$제거용 코로나 방전장치에서 OH 발광 스펙트럼 측정 및 관련 반응 연구 (Study on the Measurement of Emission Spectrum and Reaction Mechanism of OH Radical in the Nitrogen Corona Discharge System for Removal of $NO_x$ in Flue Gas)

  • 박철웅;한재원;신동남
    • 한국연소학회지
    • /
    • 제4권1호
    • /
    • pp.27-38
    • /
    • 1999
  • We constructed a wire-cylinder type pulsed corona discharge system for $NO_x$ removal, which was operated in room temperature. A emission spectrometer was built with a boxcar averager and monochrometer equipped with photo-multiplier tube detector. The sensitivity of the emission spectrometer was greatly improved by synchronizing the emission spectrometer with pulsed corona discharge system using a triggered spark-gap switch. $N_2$ spectrum($c^3{\Pi}_u{\rightarrow}X^1{\Sigma}_g{^+}$) was measured in the range of 300 - 450 nm and oxidizing OH radical emission($A^2{\Sigma}^+{\rightarrow}X^2{\Pi}$) was measured in case $N_2$ was supplied with water bubbling. As wet gas composition of inlet $N_2$ supplied in the discharge system increased, the intensity of OH emission was increased and saturated at wet gas composition 50%. We also investigated additive effect of $C_2H_4,\;H_2O,\;H_2O_2$ on the intensity of OR emission and $NO/NO_2/NO_x$ reduction and analysed the related reaction mechanism in corona discharge process. $H_2O_2$ additive increased the intensity of OH emission and $NO/NO_x$ reduction.

  • PDF

밀리미터 신호생성을 위한 헤테로다인 기법 및 실험적 해석 (Experimental Analyses and Heterodyne Method for Millimeter Wave Signal Generation)

  • 김정태
    • 한국정보통신학회논문지
    • /
    • 제10권12호
    • /
    • pp.2289-2295
    • /
    • 2006
  • 본 논문에서는 밀리미터파 대역의 신호 발생을 위한 헤테로다인 방식을 제안하고 실험적으로 분석하였다. 향후, 무선 이동통신, 초고속 광대역 통신망 등에 사용되어질 밀리 미터 파 신호는 전기적 요소의 한계로 광학적인 요소에 의해 신호를 생성하는 방법이 많이 연구되고 있다. 광학적 요소에 기술에 의한 소자기술 등이 발전되고 있다. 따라서 본 논문에서는 향후 밀리미터파 대역에서 사용되어질 LMDS(Local Multi-point Distribution Service) 등의 시 스템에서 수십기가 헤르츠급의 광원으로 응용 가능한 헤테로다인 방식을 이용한 밀리미터파 신호의 생성에 대한 이론적 방법 및 실험적 고찰을 통하여 검증하였다.

A Comparison of Signal Processing Techniques in Optical Current Sensor for GIS

  • Kim, Young-Min;Park, Jung-Hwan;Jee, Seung-Wook;Lee, Kwang-Sik;Kim, Jung-Bae;Park, Won-Zoo
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.103-109
    • /
    • 2006
  • This research is contents about output characteristic of optic current sensor that use faraday effect. optic current sensor used in an experiment is consisted of three parts.(1) Source of light used laser diode of 1310[nm].(2) Sensor section manufactured circularly according to gas insulated switchgear. And $9/125[{\mu}m]$ standard single mode optical fiber for communication was installed winding 20 [turn] on sensor section core surroundings of diameter 31 [cm].(3) Electrical signal of PD(Photo detector) is collected using NI company's 16bit DAQ board via terminal block. Collected data analyzed by different three signal processing methods. NI company's $Labview^{TM}$ was used to signal processing software. As a result, In signal processing of optic current sensor, we could know that noise greatly more influences the error generation than fluctuation of light intensity. also, 1 class CT(current transformer) manufacture that have error rate less than 1[%] was available by removing these

레이저 용접품질 해석용 플라즈마 감시장치 개발 (Development of Plasma Monitoring System for Laser Welding Quality Analysis)

  • 권장우;권오상;장영건;이경돈;홍승홍
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.425-431
    • /
    • 1999
  • 본 연구에서는 플라즈마 감시에 의한 용접성 평가방식을 채택한다. 플라즈마에서 발생하는 자외선신호를 반도체 광센서를 사용하여 검출하고, 감시장치로 쓰이는 개인용 컴퓨터에 고속으로 전달, 저장하는 장치를 개발한다. 이 장치를 사용하여 용접 데이터베이스를 구축하고, 용접성과 플라즈마 신호와의 관계를 평가하고, 분석할 것이다. 이 분야에 대한 연구동향을 하면 표2와 같다. 그러나 이 연구들은 모두 사용한 장치의 특성, 플라즈마발생원에 대한 센서의 상대적 위치 및 자세와 획득 신호와의 관계, 용접할 때 발생하는 열의 센서에 대한 영향, 잡음이 취득된 신호에 미치는 영향 및 회피방법 둥에 대한 언급이 없다. 따라서 논문에 실린 신호의 파형은 대부분 일관성이 없으며, 참고가 어렵다. 본 연구에서는 이러한 관계를 도출하고, 특히 잡음의 영향을 최소화하는 장치화에 주안점을 둔다.

  • PDF

레이저를 이용한 박판 버의 정밀측정 (Precision measuring of burrs on sheet metal using the laser)

  • 신홍규;홍남표;김헌영;김병희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1824-1827
    • /
    • 2003
  • The sheet metal shearing process is normally used in the precision elements such as semi-conductor components. In precision elements, burrs usually reduce the quality of machined parts and cause interference, jamming and misalignment during assembly procedures and because of their sharpness, they can be safety hazard to personnel. Furthermore, not only burrs are hard to predict and avoid, but also deburring, the process of removing burrs, is time-consuming and costly. In order to get the burr-free parts, therefore, we developed the precise burr measuring system using the laser. The laser burr measuring system consists of the laser probe, the photo detector, the achromatic doublet lens, and the rotary & the X-Y table. In previous reports, we used simple vertical measuring method. But, as we used relatively bigger laser spot diameter and had the limited reflection angle, it was difficult to obtain the precise measuring results. So called, the spot size effect makes the profile of burr measured distorted and the burr height measured smaller. By introducing the novel laser measuring method which employing the achromatic lens system and the tilting mechanism, we could make the spot size smaller and get the appropriate beam direction angle. Through the experiments, the accuracy of the developed system is proved. The burr height measured during the punching process can be used for automatic deburring and in-situ aligning.

  • PDF