• Title/Summary/Keyword: Phosphate glass

Search Result 170, Processing Time 0.03 seconds

COMPARATIVE STUDY ON THE BOND STRENGTH OF CEMENTS BETWEEN PFM COPING AND VARIOUS CORES (도재전장관용 Coping과 수종 Core간의 시멘트 결합력에 관한 비교 연구)

  • Paik, Sung-Ki;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 1982
  • An in vitro study was conducted to compare the bond strength of cements between Verabond coping and various cores. Fifty-four idential cores simulating maxillary central incisor prepared for PFM crowns were made. Eighteen samples were made with 20K cast gold, eighteen with Verabond, and eighteen with Adaptic. Samples were randomly divided into three groups, each consisting of six 20K cast gold, six verabond, and six Adaptic samples. The first group was cemented with zinc phosphate cement, the second group with poly-carboxylate cement, and the third group with glass ionomer cement. Constant finger pressure was applied for cementation. The sample were then stored at $37^{\circ}C$ in distilled water bath for 24 hours. The tensile strength test was performed on an Instron Universal test machine with crosshead speed of 0.05cm/min and the results compared statistically. Results of the study showed that: 1. A significant difference of bond strength was observed with different types of dental cements and core materials. 2. With gold core, zinc phosphate cement was stronger than both the polycarboxylate cement and glass ionomer cement, which did not differ in bond strength. 3. With base-metal core, zinc phosphate cement showed the highest bond strength and was followed by polycarboxylate cement and glass ionomer cement. 4. With composite resin core, zinc phosphate cement showed the highest bond strength and was followed by glass ionomer cement and polycarboxylate cement. 5. The base-metal core (Verabond core) privided the highest retention of all core materials.

  • PDF

Effect of cement type on the color attributes of a zirconia ceramic

  • Tabatabaian, Farhad;Khodaei, Maliheh Habib;Namdari, Mahshid;Mahshid, Minoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.449-456
    • /
    • 2016
  • PURPOSE. This in vitro study evaluated the effects of four different cements on the color attributes of a zirconia ceramic. MATERIALS AND METHODS. 40 zirconia ceramic disk specimens (0.5 mm thickness, 10 mm diameter, 0.1 mm cement space) were fabricated by a computer-aided design and computer-aided manufacturing system. The specimens were divided into 4 groups of 10 specimens and cemented to composite substrates using four different cements including: Glass Ionomer, Panavia F2.0, Zinc Phosphate, and TempBond. The $L^*$, $a^*$, and $b^*$ color attributes of the specimens were measured before and after cementation by a spectrophotometer. Additionally, ${\Delta}E$ values were measured to determine color changes for the groups and then compared with the perceptional threshold of ${\Delta}E=3.3$. Repeated Measures ANOVA, Tukey Post Hoc, Bonferroni, One-way ANOVA, and One-sample t-test tests were used to analyze the data. All tests were carried out at the 0.05 level of significance. RESULTS. Statistically significant differences were detected in the ${\Delta}E$ values for Zinc Phosphate (P<.0001) and TempBond (P<.0001) groups. However, there were no statistically significant differences in this respect for Glass Ionomer (P=.99) and Panavia F2.0 (P=1) groups. The means and standard deviations of the ${\Delta}E$ values for Glass Ionomer, Panavia F2.0, Zinc Phosphate, and Tempbond groups were $2.11{\pm}0.66$, $0.94{\pm}0.39$, $5.77{\pm}0.83$, and $7.50{\pm}1.16$ Unit, respectively. CONCLUSION. Within the limitations of this study, it was concluded that Zinc Phosphate and Tempbond cements affected the color attributes of the tested zirconia ceramic beyond the perceptional threshold. However, Glass Ionomer and Panavia F2.0 cements created acceptable color changes.

A STUDY ON THE RETENTION OF CAST POST (주조 포스트의 유지력에 관한 연구)

  • Kim Sung-Hoon;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.461-467
    • /
    • 1993
  • The purpose of this study was to evaluate the effects of method for construction of cast post and type of dental cement on the retention of cast post. The wax patterns or Duralay resin patterns were used for construction of cast post. The dental cements used in this study were zinc phosphate cement(Fleck's zinc cement, Mizzy INc., U.S.A.), glass ionomer cement(Fuji I, G-C Co., Japan), and resin cement(Panavia-EX, Kuraray Co., Japan) and the retention of cast post was measured with Instron Universal Test Machine(Instron Engineering Co., U.S.A.). The obtained results were as follows : 1. The tensile bond strength of cast posts made by Duralay resin patterns revealed 39.13(kg) with Panavia-EX, 46.40(kg) with phosphate cement, and 37.78(kg) with glass ionomer cement. 2. The tensile bond strength of cast posts made by wax patterns revealed 39.25(kg) with Panavia, EX, 44.12(kg) with phosphate cement, and 40.23(kg) with glass ionomer cement. 3. The tensile bond strength of cast posts made by Duralay resin patterns or wax patterns were not affected by the type of dental cements(P>0.05).

  • PDF

Development and Characterization of Translucent Opal Glass for Diffuser of LED Lighting (LED 조명용 반투명 유백유리 Diffuser 조성 개발 및 특성)

  • Ku, Hyun-Woo;Lim, Tae-Young;Hwang, Jonghee;Kim, Jin-Ho;Lee, Mi-Jai;Shin, Dong Wook
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.650-657
    • /
    • 2012
  • For the purpose of improving the durability problem, translucent opal glass was fabricated as a substitute for the polycarbonate diffuser of LED lighting. Calcium phosphate was used as an opacifier of opal glass and melted in an electric furnace. The opaque effect was identified according to the change of the cooling procedure. As results, translucent opal glass was obtained by the melting of a batch with a composition of 3.8% calcium phosphate at $1550^{\circ}C$ for 2 hrs and then the cooling of the material in the furnace. For the cooling condition of the glass sample, HTCG (High Temperature Cooled Glass) was found to have better optical properties than LTAG (Low Temperature Annealed Glass). It had excellent optical properties for a diffuser of LED lighting, with no dazzling from direct light due to its high haze value of over 99% and low parallel transmittance value of under 1%. For the thermal properties, it had an expressed thermal expansion coefficient of $5.7{\times}10^{-6}/^{\circ}C$ and a softening point of $876^{\circ}C$; it also had good thermal properties such as good thermal shock resistance and was easy to apply to the general manufacturing process in the forming of glass tubes and bulbs. Therefore, it is concluded that this translucent opal glass can be used as a glass diffuser material for LED lighting with high heat resistance and high durability; this material is suitable as a substitute for polycarbonate diffusers.

Glass Formation and Ion Dissolution of P2O5-K2O-FeO-CuO Glasses (P2O5-K2O-FeO-CuO계 유리형성 및 이온용출)

  • Kang, Won-Ho;Kim, Ki-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.604-607
    • /
    • 2010
  • The glass formation and the dissolution property in $P_2O_5-K_2O$-FeO-CuO system were studied. In the batch process, the content of P2O5 was fixed at 60mol% and the other elements were varied from 10~40mol%. The prepared glasses were soaked in the D.I. water up to 13hr and the dissolution properties were investigated with the solutions sampled every 2 hr. The result shows that the $P_2O_5$ was leached out firstly from Phosphate glass system and then Cu and Fe ions were observed according to atmosphere change in solution. ICP shows that the dissolution amount in Phosphate was depended on the glass structure and the highest dissolution amount of CuO and FeO ions was observed when the 10mol% $K_2O$ was added in batch process.

Compositional Effects of $CaO-SiO_2-P_2O_5$ Bioactive Cement on Hardening and Hydroxyapatite Formation ($CaO-SiO_2-P_2O_5$계 바이오 시멘트 유리의 조성이 경화 및 Hydroxyapatite 형성에 미치는 영향)

  • 박상종;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.5
    • /
    • pp.505-512
    • /
    • 1994
  • It has been reported that a biocement obtained by mixing CaO-SiO2-P2O5 glass powder and ammonium phosphate solution has biocompatibility as well as high strength. However, the compositional dependence on its hardening and hydroxyapatite formation phenomena has not been studied. Therefore, the main objective of this work is to study the effects of P2O5, MgO in CaO-SiO2 system glass on the hardening and hydroxyapatite formation. When more than 50 mole% of CaO containing CaO-SiO2 glasses was reacted with ammonium phosphate solution, CaNH4PO4.H2O crystal was formed, but the glass with less than 50 mol% of CaO formed (NH4)2HPO4 and NH4H2PO4 crystals which are derived from ammonium phosphate solution without reacting with the glasses. As the amount of P2O5 in CaO-SiO2-P2O5 glass system was increased, the formation of CaNH4PO4.H2O crystal was enhanced. When those hardened samples were reacted with tris-buffer solution, hydroxyapatite was obtained only for the sample with CaNH4PO4.H2O. While the substitution of MgO for CaO decreased the formation of CaNH4PO4.H2O crystal. MgNH4PO4.H2O crystla was formed in high MgO containing glass, which did not react with tris-buffer solution.

  • PDF

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

AN EXPERIMENTAL STUDY OF THE PULP RESPONSES ON THE EFFECT OF BASE MATERIALS BY REMAINING DENTIN THICKNESS (수종 이장재의 잔존상아질후경에 따른 성견치수반응에 대한 실험적 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.307-322
    • /
    • 1988
  • The purpose of this study is to evaluate the pulpal responses to the base materials such as zinc oxide eugenol cement, calcium hydroxide, zinc phosphate cement, polycarboxylate cement and glass ionomer cement. The 100 caries free dog teeth were devided into 2 groups by remaining dentin thickness (Group A: 0.4-0.6 mm, Group B: 0.8-1.0 mm) and each group were devided into 5 subgroups. The intervals of observation period are 3days, 1 week, 2 weeks, 4 weeks and 8 weeks respectively after experiment. The specimens were fixed with 10% formalin and decalcifed in 5% nitric acid. All specimens were stained with Hematoxylin-Eosin and examined histopathologically. The results were as follows. 1. In group A, atropy or hyperplasia in odontoblasts were seen in zinc oxide eugenol cement, calcium hydroxide and zinc phosphate cement. No changes in odontoblasts were seen in polycarboxylate cement and glass ionomer cement. 2. In group A, increase of predentin were seen in all experimental materials. 3. In group A, vascular congestion were seen in all experimental materials and inflammation were seen on 3 days in zinc oxide eugenol cement, 8 weeks in zinc phosphate cement and hemorrage were seen on 3 days in zinc phosphate cement. 4. In group B, changes of odontoblasts were not seen all experimental materials. 5. In group B, increase of predentin and vascular congestion were seen in all experimental materials but inflammation were not seen.

  • PDF

THE MEASUREMENT OF EXOTHERMIC TEMPERATURE OF VARIOUS DENTAL CEMENTS (각종 치과용 세멘트의 경화열 측정)

  • Pahk, Deok-Sang
    • The Journal of the Korean dental association
    • /
    • v.10 no.8
    • /
    • pp.531-534
    • /
    • 1972
  • The author measured exothermic temperature of the 5 kinds of zinc phosphate cement and 3 kinds of copper phosphate cement during setting process. Cements were mixed on the glass slab with flexible steel spatula at room temperature (25.8℃) for one minute (spatulating speed was 100 strokes per minute) and placed in the incubator of which temperature was held at 37℃ and thermometer was inserted into the cement mass. The powder liquid ration was 3.0gm:1ml and 1.5gm:1ml. The results were as follows. 1) The heat generated after mixing these cements was under 47.22℃. 2) The range of thermal change of the zinc phosphate cements during setting process was wider than copper phosphate cements. 3) The exothermic temperature from the thin mix was higher than thick mix. 4) The exothermic temperature of the zinc phosphate cements was higher than copper phosphate cements.

  • PDF

A COMPARISON OF THE BOND STRENGTHS BETWEEN SOME CEMENTS AND STAINLESS STEEL MATERIAL (Stainless steel crown을 위한 수종 시멘트의 접착력 비교)

  • Kim, Hong-Ryoul;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.528-537
    • /
    • 1999
  • The purpose of this study was to analyze and compare the bond strengths between stainless steel plate and zinc phosphate cement, polycarboxylate cement and glass ionomer cement, which are frequently used for cementation of stainless steel crowns. Three cementing materials were glued to the poles standing above stainless steel plate, bovine teeth, light cured glass ionomer restorative material and amalgam. And the tensile bond strengths between them were measured with universal testing machine and the results were statistically processed using ANOVA and Student t-test. The obtained results were as follows : 1. On stainless steel plate, glass ionomer cement and polycarboxylate cement showed higher tensile bond strengths compared to zinc phosphate cement, with no significant difference between the former two. 2. On the surface of bovine teeth and glass ionomer restorative material, glass ionomer cement showed highest bond strength, followed by polycarboxylate cement and zinc phosphate cement in order. 3. For amalgam restoration, polycarboxylate cement and glass ionomer cement showed higher tensile bond strengths than zinc phosphate cement, with no significant difference between the former two.

  • PDF