A Study on Safety Improvement for Packaged Hydrogen Refueling Station by Risk Assessment (위험성 평가를 통한 패키지형 수소충전소 안전성 향상에 관한 연구)

  • KANG, SEUNGKYU;HUH, YUNSIL;MOON, JONGSAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.635-641
    • /
    • 2017
  • In this study, the components of packaged hydrogen filling station were analyzed and risk factors were examined. Risk scenarios were constructed and quantitative risk assessments were conducted through a general risk assessment program (phast/safeti 7.2). Through the risk assessment, the range of damage according to accident scenarios and the ranking that affects the damage according to the risk factors are listed, and scope of damage and countermeasures for risk reduction are provided. The quantitative risk assessment result of the packaged hydrogen filling station through this task will be used as the basic data for improving the safety of the packaged filling system and preparing safety standards.

Development of Emergency Response System for Toxic Gas Facilities Using Quantitative Risk Analysis (독성가스 시설의 정량적 위험성 평가를 이용한 비상대응시스템 구축)

  • Yoo Jin Hwan;Kim Min Seop;Ko Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.43-49
    • /
    • 2005
  • Today toxic gas has various uses. If there is a release accident, the gas rapidly disperse into the atmosphere. The extent of damage due to toxic gas accident is very wide and fatal to human being. So, it is necessary for toxic gas facilities which have high risk to construct an emergency response system that prepare to toxic release and make immediate response to be possible at accident appearance. In this study accident scenario were selected and frequency analysis was executed using FTA technique. Dispersion effect of toxic gas release was analyzed using DNV company's PHAST(Ver. 6.2). Finally, an emergency response system was developed using results of quantitative risk analysis.

  • PDF

A Study of Risk Analysis for Underground-parking of Gas Vehicle (가스 자동차의 지하 주차 시 위험성 분석)

  • Rhie, Kwang-Won;Kim, Tae-Hun;Oh, Dong-Seok;Oh, Young-Dal;Seo, Doo-Hyoun;Shin, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • We studied the risk analysis of fire and explosion caused by gas leak in underground-parking of gas vehicle. However, an entrance regulation of gas vehicles (H2/LPG/CNG etc.) to underground garages has not been enacted in Korea. Incase, a gas explodes in an underground parking garage placed in overcrowded residential area, such as an apartment, the scale of the damage would cause tremendous disaster. Faults of vehicle parts and management problems were evaluated by using the Failure mode and effect analysis (FMEA), which is a qualitative analysis method. The range of the damaged area by the explosion and the damage scale by the explosion pressure were analyzed by using the process hazard analysis software tool (PHAST). The study is expected to facilitate enactment of the regulation for the underground parking to restrict the gas vehicle.

Verification on Separation Distance Criteria when Transporting Dangerous Goods in Korea Railroad (국내 철도 위험물 운송 시 격리차 운영기준 안전성 검증)

  • Lee, Byeongwoo;Park, Dasung;Kang, Taesun;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.2
    • /
    • pp.28-33
    • /
    • 2019
  • After the Tianjin Port explosion on 2015, it is highlighted that securing safety for dangerous goods in Korea and try to establish safety standards for railroad dangerous substances transport. In Korea, the regulation for the transport of dangerous goods is stipulated to need 3 buffer cars. However, It is inefficient that 3 buffer cars. because 3 buffer cars, increase transportation too much costs in transit and it is too strict compared to other country rules. The purpose of this study was to improve transportation efficiency by mitigating the criteria for isolated railroads through rational safety assessment. In order to verify this, we used a risk assessment software which is PHAST 7.2 developed by DNV GL. We calculated safety distances that could prevent ignitions setting up scenarios when relief system work installed on a train loaded with propylene, nonane. As a result, we confirmed that buffer cars can be reduced from three to one. This result would be implemented in the application of Korail.

A Study on Hydrogen Energy Safety according to the Revitalization of the Hydrogen Economy (수소경제 활성화에 따른 수소에너지 안전성 고찰)

  • Park, Woo-Il;Tak, Song-Su;Lee, In-Woo;Hong, Soon-Pa
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.74-79
    • /
    • 2021
  • This study analyzed the current status of the global hydrogen economy and the safety of energy sources currently in use due to the activation of the hydrogen economy. Understanding the hydrogen economy, identifying government policy trends, comparing and analyzing characteristics with existing energy sources such as gasoline, propane, and methane, and evaluating damage impact for each energy source using PHAST, a quantitative damage impact assessment program. Using the analysis results, this study analyzes the safety of hydrogen energy to revitalize the hydrogen economy and suggests ways to improve safety.

Consequence Analysis for Accidental Gas Release in Labs (실험실 가스 누출 시 피해 영향 분석)

  • Jang, Yuri;Jung, Seungho;Park, Kyoshik
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.29-34
    • /
    • 2015
  • Accidents in laboratory dealing with chemicals have constantly occurred. In the case of a gas explosion or an accident related to leakage of chemical materials, the damage is much greater, thereby leading to a serious accident. Especially, the safety of laboratory in University is important because students build up knowledge and skills and accumulate experience as the main researchers. In this paper, 5 gases(CO, $NH_3$, $H_2$, $CH_4$, $N_2$) are selected to model since they are often used in university laboratories. From the scenarios where the gases are released, the diffusion process is estimated and analyzed to predict damage degree by PHAST v.6.7. Internal diffusion process is modeled through FLUENT which is Computational Fluid Dynamics(CFD) tool. Also, we compare indoor damage with outdoor one when discharged to the outside through the laboratory's window. In the modeling results, the outdoor damages for accident scenarios in the results are far less than then of real plants since the vessel usually used in laboratory(i.e. the capacity of the cylinder; 47 L or less) is significantly less than workplace's one(using ton measure). However as shown in the results small amount can have high consequences for indoor accidents.

A Study on Fire Explosion Characteristics via Physico-chemical Analysis of Petroleum Residues (석유 부산물의 물리화학적 분석을 통한 화재폭발 특성연구)

  • Kim, Hyeonggi;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.556-561
    • /
    • 2019
  • In this study, the physical and chemical analyses of petroleum residues (pyrolized fuel oil, PFO) were conducted and major components were selected to investigate their fire and explosion characteristics. Major component distribution areas of the PFO were identified via the GC-SIMDIS and MALDI-TOF analyses. In addition, the qualitative analysis of major component distribution areas was performed by GC-MS analysis. Major components of pyrolysis residue were selected based on the results of various analyses such as EA, SARA and TGA. As a result, benzene, toluene and xylene were selected as major components. Finally, the process hazard analysis software tool (PHAST) analysis was performed to investigate the range of maximum damage effect in case of fire and explosion. Toluene presented the highest risk due to the radiation effect of $227kW/m^2$ and 118 m in the case of jet fire. Xylene and benzene showed the maximum radiant heat values of 114 and $151kW/m^2$, respectively. It was also confirmed from the analysis of pasquill stability and wind speed that the radiant heat increased up to 55% according to wind speed in benzene, which was considered to be a main factor increasing the influence range.

Comparative Analysis of IEC Standard and Simulation Results for Hydrogen Hazardous Distance (수소 폭발위험범위에 대한 IEC기준과 시뮬레이션 결과의 비교분석)

  • Seung-Hyo An;Eun-Hee Kim;Seon-Hee Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • In workplaces handling flammable gas such as hydrogen, hazardous area is determined through KS C IEC 60079-10-1 standard. Because this standard determines the hazardous distance based on the release characteristic regardless of the type of gas, indoor/outdoor conditions, and atmospheric conditions, concerns are being raised about the effectiveness. In this study, simulations (PHAST, HyRAM) were performed to calculate the hazardous distance for hydrogen under various release characteristics and atmospheric conditions, and compared these results to IEC standard log-log graph. Also, we performed regression analysis according to each result. we found that the simulation results were 0.6 to 3.8 times less than the IEC standard, presented convenient linear regression equations. In addition, We confirmed that the results of hazardous distance varied based on wind velocity and atmospheric stability at the same release characteristic. In addition, we derived linear regression equations for release characteristics and hazardous distance that can be conveniently utilized. So, when classifying hazardous area in workplaces where they handle the hydrogen, the integrated graph and linear regression equation are helpful for confirming the hazardous area. Moreover, it is expected that the economic burden will be minimized by being able to classify reasonable hazardous area and to greatly reduce the risk of hydrogen explosion.

The Development of Risk Assessment Program PML-Chem (위험성 평가 프로그램 PML-Chem 개발)

  • 김윤화;김형석;신동일;김인원;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.97-102
    • /
    • 1999
  • This study is to develope the quantitative risk assessment program for consequence analysis of fire and explosion (PML-Chem), which is applicable to the chemical plants. The advantages of PML-Chem is easy to use and acquire results. Especially, PML-Chem was embedded real weather condition database for major chemical plants in ${\bigcirc}{\bigcirc}$ complex in country. Also, reliability of PML-Chem was verified through comparing PML-Chem with PHAST-Professional which is already commercial.

  • PDF

LPG충전소의 BLEVE현상에 따른 피해 분석

  • Jo, Sam-Gyu;Kim, Tae-Hwan;Ham, Eun-Gu
    • LP가스
    • /
    • s.67
    • /
    • pp.26-32
    • /
    • 2000
  • 도심지내에 위치한 부천 LPG충전소 사고 조사를 통하여 가장 피해효과가 큰 탱크로리 폭발에 따른 결과를 분석하였다. 분석범위는 BLEVE 현상에 의한 방출열과 과압이 충전소 주변에 위치한 구조물이나 인체에 미치는 영향을 대상으로 실제 현장조사를 통하여 수집된 피해결과와 이론적인 모델(PHAST-Process Hazad Analysis Software Tools) 분석 결과를 비교하였다. 부천 LPG 충전소 폭발 사고의 피해효과는 방출열의 경우 두 가지 모두 큰 차이를 보이지 않았으나 과압의 경우, 실제 피해는 이론적 모델 분석결과의 약 15%정도에 해당하는 축소된 거리에서 나타났다. 또한 충전소 인근에 위치한 구조물에 대한 피해효과는 부분적으로 과압에 의한 균열 및 붕괴 현상보다는 열 효과에 의한 콘크리트 강도 저하와 성상변화가 크게 나타났다.

  • PDF