• Title/Summary/Keyword: Phast

Search Result 54, Processing Time 0.024 seconds

A Study on the Reasonable Estimation of Consequence of Chemical Release (화학사고 피해영향 범위의 합리적 산정방안에 대한 연구)

  • Cho, Guysun;Lim, Juntaig;Han, Jeongwoo;Baek, Eunsung;Yu, Wonjong;Park, Kyoshik
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.20-28
    • /
    • 2020
  • In this study, the damage impact range in the case of a hydrofluoric acid leak accident was predicted using formula calculation, impact assessment simulations, and CFD simulations, and the results were compared and analyzed with the actual environmental impact report. Formula calculation was performed by using the leak source model and diffusion model. Impact assessment simulation was performed by KORA provided by the Korean Ministry of Environment, ALOHA by the United States Ministry of Environment, and PHAST, which is relatively widely used among commercialization programs, and the STAD-CMM+program for CFD simulation. Was utilized. Considering convenience, speed, acceptability, and economics from the user's perspective, ALOHA and KORA were the most appropriate methods for predicting the impact of hydrofluoric acid leakage. In addition, the results of this study will help to reduce unnecessary regulations in the process of government policy development and optimize the investment in the safety field of the company, effectively utilizing the limited resources of the government and the company.

A Study on Gas Explosion Hazardous Ranges for International Electrotechnical Commission Technical Standards (IEC 기술표준의 가스폭발위험범위 연구)

  • Jung, Jae Yong;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.39-45
    • /
    • 2018
  • The occupational safety and health act defines how to evaluate the explosion hazardous areas according to KS (Korean Industrial Standards). Current KS have to follow IEC (International Electrotechnical Commission) 60079-10-1 1st edition and there has been no change since 2008. And its 2nd edition has been revised in 2015. In this study, IEC 1st Ed. (IEC 60079-10-1 1st edition) is compared with IEC 2nd edition. Total 112 case studies including four materials (methane, propane, benzene, methanol) are selected to test and explosion hazardous ranges evaluated by IEC 1st and 2nd Ed. are analyzed according to various leakage pressures and hole sizes. In order to verify the results calculated by them, PHAST, which is one of the most representative consequence analysis programs, is employed. As a result, it can be concluded that there are many differences between IEC 1st and 2nd Ed. due to the discharge and the ventilation parameters. As comparing with PHAST, it is confirmed that IEC 1st provides more conservative values than PHAST. Even if IEC 2nd Ed. provides more conservative for gases, this fails to provide more conservative values for liquids. Therefore, it is worth to note that a large value between the explosion hazardous ranges value calculated by the IEC 1st Ed. and 2nd Ed. should be selected until further investigation and analysis is made. Morevover, the full consideration for IEC 2nd Ed. have to be needed.

Offsite Consequence Modeling for Evacuation Distances against Accidental Hydrogen Fluoride (HF) Release Scenarios (Hydrogen Fluoride (HF) 누출 사고 시 피해 범위 예측 및 장외영향평가를 위한 모델링 활용 방법)

  • Kim, Jeonghwan;Jung, Seungho
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.582-585
    • /
    • 2016
  • This study intends to provide initial evacuation distances for the public in case of accidental releases of hydrogen fluoride (HF). HF is a very toxic chemical that is widely used in the chemical, electrical, and electronics industries. Consequence modeling programs, such as ALOHA and PHAST, were used to help formulate a contingency plan in case of an HF leak. For the purpose of this study, the release of entire quantity of HF in 10 min is defined as a worst-case scenario and the release from a partial line rupture is used as an alternative case scenario as National Institute of Chemical Safety (NICS) guidelines. Once the discharge rates were calculated based on the scenarios, the ERPG-2 endpoint distances have been obtained for representative daytime and nighttime weather conditions. This paper presents graphs that can be used to enact swift evacuation orders and emergency response plans in the case of accidental releases of HF.

An Estimation of the Consequence Analysis for an Underground Installation of the LPG Storage Tanks (소형 LPG 저장탱크 매몰 설치에 대한 피해영향평가)

  • Song, Dong-Woo;Jun, Woon-Young;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.62-67
    • /
    • 2015
  • In this paper, the consequence analysis has been evaluated for the damage effects of the LPG storage tanks when they are installed on the ground or underground. They should be performed to identify measures to reduce risks for the LPG storage tanks which are more widely used. In order to conduct a damage effect evaluation of the LPG storage tanks installed underground, FDS was used to simulate the LPG storage tanks installed and housed within a facility. The maximum pressure of the storage facilities for the LPG storage tanks has been calculated from the FDS, and it's results are used as an input variable for Phast which is a commercial software for evaluating the damage effects. Getting results from the consequence analysis and computational simulations(diffusion range of LFL and UFL, jet fire or explosions) were quantitatively presented for the damage effects.

A Study on the Safety Improvement of City Gas Pressure Regulators in Apartment Housing (공동주택 등에 설치하는 도시가스 압력조정기의 안전성 향상에 관한 연구)

  • Youngman Yun;Yongchai Kwon;Kyungho Kim;Jihyun Jang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.86-94
    • /
    • 2023
  • This study was conducted with the purpose of preparing an alternative to improving the safety of civil pressure regulators installed instead of gas governors to supply city gas to apartment houses. First, problems were derived and solutions were presented by investigating the safety standards and installation status of domestic pressure regulators. In addition, using the DNV Phast-Safeti program, a quantitative risk assessment solution, risks such as gas leakage contained in pressure regulators installed in apartment houses and surrounding gas facilities were evaluated in terms of individual risks and societal risks, and measures were derived to reduce the risks in the installation and management of the pressure regulators.

Suggestions for Safety Improvement of CNG Bus Based on Accident and Failure Analysis (CNG버스 사고원인 분석에 근거한 안전성 향상 방안에 대한 연구)

  • Yoon, Jae-Kun;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.69-76
    • /
    • 2008
  • Three failure cases of CNG composite vessels were reported since after January 2005. The 1st and 2nd accidents were indebted to vessel defect and installation mistake. The 3rd was caused by gas leak at pipe connections. In this paper various aspects were studied based on information of the three failure analysis, which must be improved for better safety of the CNG bus system. Overpressure region caused by vessel explosion was theoretically predicted and also assessed by PHAST program. Explosion of 120 l vessel under 20 MPa is equivalent to 1.2 kg TNT explosion. The predicted value by PHAST was more serious than theoretical one. However, actual consequence of explosion was much less than both of the predicted consequences. Since the CNG vessel was designed by the performance based design methodology, it is difficult to verify whether the required process and tests were properly conducted or not after production. If material toughness is not enough, the vessel should be weak in brittle fracture at early in the morning of winter season since the metal temperature can be lower than the transition temperature. If autofrettage pressure is not correct, fatigue failure due to tensile stress during repeated charging is possible. One positive aspect is that fire did not ocurred after vessel failure. This may be indebted to fast diffusion of natural gas which hindered starting fire.

  • PDF

Improved Socio-Economic Status of a Community Population Following Schistosomiasis and Intestinal Worm Control Interventions on Kome Island, North-Western Tanzania

  • Mwanga, Joseph R.;Kaatano, Godfrey M.;Siza, Julius E.;Chang, Su Young;Ko, Yunsuk;Kullaya, Cyril M.;Nsabo, Jackson;Eom, Keeseon S.;Yong, Tai-Soon;Chai, Jong-Yil;Min, Duk-Young;Rim, Han-Jong;Changalucha, John M.
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.5
    • /
    • pp.553-559
    • /
    • 2015
  • Research on micro-level assessment of the changes of socio-economic status following health interventions is very scarce. The use of household asset data to determine wealth indices is a common procedure for estimating socio-economic position in resource poor settings. In such settings information about income is usually lacking, and the collection of individual consumption or expenditure data would require in-depth interviews, posing a considerable risk of bias. In this study, we determined the socio-economic status of 213 households in a community population in an island in the north-western Tanzania before and 3 year after implementation of a participatory hygiene and sanitation transformation (PHAST) intervention to control schistosomiasis and intestinal worm infections. We constructed a household 'wealth index' based housing construction features (e.g., type of roof, walls, and floor) and durable assets ownership (e.g., bicycle, radio, etc.). We employed principal components analysis and classified households into wealth quintiles. The study revealed that asset variables with positive factor scores were associated with higher socio-economic status, whereas asset variables with negative factor scores were associated with lower socio-economic status. Overall, households which were rated as the poorest and very poor were on the decrease, whereas those rated as poor, less poor, and the least poor were on the increase after PHAST intervention. This decrease/increase was significant. The median shifted from -0.4376677 to 0.5001073, and the mean from -0.2605787 (SD; 2.005688) to 0.2605787 (SD; 1.831199). The difference in socio-economic status of the people between the 2 phases was highly statistically significant (P<0.001). We argue that finding of this study should be treated with caution as there were other interventions to control schistosomiasis and intestinal worm infections which were running concurrently on Kome Island apart from PHAST intervention.

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

The Quantitative Risk Analysis in Rail Transport of Propylene (프로필렌의 철도 수송에 따른 정량적 위험성 평가)

  • Lee, Jae-Hean;Song, Dong-Woo;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.38-44
    • /
    • 2010
  • This treatise analyzed the risk of propylene transported by railroad through quantitative analysis. As a result of survey on propylene transportation route, Iksan station, Suncheon station and Jeonju station were selected as object regions those were expected to have high accident risks. This treatise deduced the scenario of accident and the occurrence rate in accordance with the type of accident possibly to be happening during propylene transportation through ETA( Event Tree Analysis), and expressed the level of personal, social risks after calculating the level of demage influencing over surroundings based on the evaluation for the expected accident damage through PHAST 6.53.

Planning for Safety Control on LPG Distribution Depot (LPG 판매업소의 위험성 제어계획)

  • 노삼규;전성우;강태희;서영민
    • Fire Science and Engineering
    • /
    • v.12 no.4
    • /
    • pp.21-30
    • /
    • 1998
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation to the neighbouring structure and human activity required to be estimated to find the gap between existing controls on such storage. PHAST and IAEA manual for risk rankings and assessment had been applied to get the required safety distance for neighbouring facilities, Japanese legal control for such facilities were also investigated. To this context the issues on LPG vessel storage required additional safety distance between existing blast wave barrier structure and safety separation distances.

  • PDF