Grating phase measurement of photopolymer hologram by self-diffraction oscillations (자체회절 진동에 의한 포토폴리머 홀로그램의 격자 위상측정)

  • 경천수;성기영;곽종훈;최옥식;이윤우;이인원;서호형;이일항
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.328-334
    • /
    • 1999
  • Methylene blue-sensitized photopolymerizable material based on acrylamide is investigated with two-wave energy coupling experiments. Differently from other studies, self-diffraction oscillations are observed and the grating phase is determined without applying external electric fields, moving nonlinear materials, and phase shifting one of two writing beams. The phase grating showed a phase shift of $\pm$50$^{\circ}$ with respect to the intensity grating. Modified Kogelnik's coupled wave equation considering the mixed gratings of phase and absorption gratings and nonzero spatial phase shifts of the gratings with respect to the intensity interference patterns formed during the two-wave energy coupling is discussed in detail to understand these phenomenon.

  • PDF

A study on the phase calibration of the phase measuring profilometry (PMP 형상 측정법의 위상보정에 관한 연구)

  • 이연태;강영준;황용선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF

Diffraction grating interferometer of large equivalent wavelength for flatness testing of rough surfaces (거친 표면 형상측정을 위한 큰 등가파장 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.1
    • /
    • pp.56-62
    • /
    • 2004
  • We present a diffraction grating interferometer of large equivalent wavelength specially designed for flatness testing of rough surfaces. Two transmission diffraction gratings are illuminated on the object under test by use of two measurement beams with different angles of incidence, which yields a large equivalent wavelength. This interferometer design minimizes unnecessary diffraction rays and the systematic error caused by the diffraction gratings, and provides a large working distance and easy alignment. To improve the measurement accuracy, phase shifting technique is applied and the equivalent wavelength error caused by defocus is calibrated. Test results obtained from mirror surfaces and machined rough surfaces are discussed.

A High-speed Digital Laser Grating Projection System for the Measurement of 3-dimensional Shapes

  • Park, Yoon-Chang;Park, Chul-Geun;Ahn, Seong-Joon;Kang, Moon-Ho;Ahn, Seung-Joon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.251-255
    • /
    • 2009
  • In the non-contact 3-dimensional (3D) shape measurements, the fringe pattern projection method based on the phase-shifting technique has been considered very effective for its high speed and accuracy. The digital fringe projector in particular has great flexibility in generating fringe patterns since the patterns can be controlled easily by the computer program. In this work, we have developed a high-speed digital laser grating projection system using a laser diode and a polygon mirror, and evaluated its performance. It has been demonstrated that all the optical measurements required to find out the profile of a 3D object could be carried out within 31 ms, which confirmed the validity of our 3D measurement system. The result implies the more important fact that the speed in 3D measurement can be enhanced remarkably since, in our novel system, there is no device like a LCD or DMD whose response time limits the measurement speed.

The shape measurement of 3D object by using the method of interference pattern projection. (간섭무늬 투영 방식의 3차원 형상 측정)

  • 이연태;강영준;박낙규;황용선;백성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.271-274
    • /
    • 2002
  • The 3-D measurement using interference pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The patters was generated by a interferometer, and a PZT was used to shift the fringes on the target surface. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. A working system requires a interferometer, a PZT, and a detector array interfaced to a microcomputer. Results of measurements on the diffused test objects are described.

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 김도훈;유원재;박낙규;강영준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

A Study of the Back Shape of the Children in Elementary and Middle Schools Using the Phase-shifting Scanning Grating Projection moire (위상천이 주사격자 영사식 모아레 간섭계를 이용한 초.중학생의 배부체형고찰)

  • 유한길;민병일;박동석
    • The Journal of Korean Medicine
    • /
    • v.21 no.4
    • /
    • pp.148-158
    • /
    • 2000
  • Objective : The purpose of this study was to investigate the back shape of school children using the phase-shifting scanning grating projection moire interferometer, which was developed by the Korea Advanced Institute of Science and Technology and is useful in evaluating three dimensional back shape. Methods : In this study the subjects consisted of 1,358 pupils [711 boys(52.36%), 647 girls(47.64%)] attending elementary and middle schools in Seoul. Their ages ranged from nine to fifteen and the average age was 12.2. With the phase-shifting scanning grating projection moire interferometer, the posterior view of the body were taken to see if there are correlations of moire fringe number, width difference between left and right, and correlation between differences in moire fringe number and width on both sides in the scapular, lumbar and gluteal regions. Results : The results were as follows : I. More frequent findings of fringe were observed on the right in all regions : in the scapular region, 309 boys(43.4%) and 156 girls(24.2%) had more fringe numbers on the right side; in the lumbar region, 68 boys(9.5%) and 11 girls(1.7%); and in the gluteal region, 160 boys(22.4%) and 63 girls(9.8%). Such tendency was striking especially in the scapular and lumbar regions, and in boys rather than in girls. In the scapula, 661 subjects(48.7%) with one moire fringe on either side need further attention and 110 subjects(8.I %) with two or more are required to do follow-up radiography for scoliosis. 2. In an analysis of width difference in the trunk, the left side is wider in all regions except for the gluteal region in boys : in the scapular region 21 boys(3.0%) and 103 girls(15.9%); in the lumbar region, 87 boys(12.2%) and 250 girls(38.6%); and in the gluteal region 197 girls(30.4%) had a wider left side and 45 boys(6.3%) showed a wider right side. 3. In correlation analysis of the number of moire fringe and width difference in each region, the side where more moire fringes were observed was significantly wider in the lumbar and gluteal regions, but not in the scapular region.(p<0.01) Conclusions : From these results, it is concluded that the back shape of elementary and middle school students in Seoul shows that the right side had more moire fringes; the left side was wider; and especially in the lumbar and gluteal regions the side where more moire fringes were observed was wider.

  • PDF

Phase-shifting Diffraction-grating Interferometer (위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.148-149
    • /
    • 2003
  • 렌즈와 거울의 형상을 정밀하게 측정하고 평가하는 광학시험에 많은 형태의 광간섭계가 개발되고 사용되어왔다. 그 중, 회절격자를 광선분할기로 사용하는 광간섭계들을 통칭하여 회절격자 간섭계라 부른다. 회절격자 간섭계는 별개의 광학표면을 사용하지 않고 회절격자에서 회절된 파면을 직접 기준파면으로 사용할 수 있으므로, 격자의 형태, 주기를 선정하여 기준파면과 측정파면을 원하는 방향으로 재생하여 다양한 형태의 간섭계를 만들 수 있다.(중략)

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 유원재;김도훈;안재웅;강영준;노형민
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF