• 제목/요약/키워드: Phase-Change Cooling

검색결과 204건 처리시간 0.024초

상변화 냉각시스템의 정량적 성능지수 연구 (A Study on Quantitative Performance Index for Phase-Change Cooling Systems)

  • 장명언;송혜은
    • 한국군사과학기술학회지
    • /
    • 제23권3호
    • /
    • pp.237-245
    • /
    • 2020
  • In this paper, I introduce Phase-Change Cooling for thermal management of high power devices that can be applied to High Power Laser and Electric Propulsion Systems which are composed of multiple distributed superheat sources. Phase-Change Cooling can be good used to efficient cooling of their heat sources. Phase-Change Cooling has extremely high efficiency of two-phase heat transport by utilizing heat of vaporization, relatively low flow rates and reduced pumps power. And I suggest TPI(Thermal Performance Index) which is a quantitative performance index of Phase-Change Cooling for thermal management. I quantify the performance of Phase-Change Cooling by introducing TPI. I present the test results of TPI's changing refrigerant, heat sink and flow rate of the Phase-Change Cooling system through the experiments and analyze these results.

상변화물질을 활용한 원통형 리튬이온 배터리 셀의 냉각성능 및 등온유지성에 관한 연구 (Study on cooling performance and isothermal maintenance of cylindrical type lithium-ion battery cell using phase change material)

  • 윤재형;현수웅;정희준;신동호
    • 한국가시화정보학회지
    • /
    • 제21권2호
    • /
    • pp.34-45
    • /
    • 2023
  • When lithium-ion batteries operate out of the proper temperature range, their performance can be significantly degraded and safety issues such as thermal runaway can occur. Therefore, battery thermal management systems are widely researched to maintain the temperature of Li-ion battery cells within the proper temperature range during the charging and discharging process. This study investigates the cooling performance and isothermal maintenance of cooling materials by measuring the surface temperature of a battery cell with or without cooling materials, such as silicone oil, thermal adhesive, and phase change materials during discharge process of battery by the experimental and numerical analysis. As a result of the experiment, the battery pack filled with phase change material showed a temperature reduction of 47.4 ℃ compared to the case of natural convection. It proves the advanced utility of the cooling unit using phase change material that is suitable for use in battery thermal management systems.

직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토 (Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load)

  • 김수경
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

냉이온수기 냉각시스템에 관한 열유동 해석 (Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus)

  • 전성오;이상준;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Cold plate를 이용한 휴대용 컴퓨터 냉각 시스템의 열성능에 관한 연구 (A Study on Thermal Performance of Cooling System for a Laptop Computer Using a Cold Plate)

  • 박상희;조남해;최성대
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.83-89
    • /
    • 2009
  • This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.

  • PDF

에탄올에 의한 TMA-포접화합물의 냉각특성 개선에 대한 연구 (A Study on the Cooling Characteristics Improvement of TMA-Water Clathrate Compound by Ethanol)

  • 이종인;김창오
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-28
    • /
    • 2007
  • This study aims to find out cooling characteristics of TMA(Tri-Methyl-Amine, $(CH_3)_3N$) 25wt%-water clathrate compound with ethanol($CH_3CH_2OH$) such as supercooling, phase change temperature and specific heat. For this purpose, ethanol is added as per weight concentration and cooling experiment is performed at $-6{\sim}-8^{\circ}C$, cooling heat source temperature, and it leads the following result. (1) Phase change temperature is decreased due to freezing point depression phenomenon. Especially, it is minimized as $3.8^{\circ}C$ according to cooling source temperature in case that 0.5wt% of ethanol is added. (2) If 0.5wt% of ethanol is added, average supercooling degree is $0.9^{\circ}C$ and minimum supercooling is 0.8, $0.7^{\circ}C$ according to cooling heat source temperature. The restraint effect of supercooling is shown. (3) Specific heat shows tendency to decrease if ethanol is added. It is $3.013{\sim}3.048\;kcal/kg^{\circ}C$ according to cooling heat source temperature if 0.5wt% of ethanol is added. Phase change temperature higher than that of water and inhibitory effect against supercooling can be confirmed through experimental study on cooling characteristics of TMA 25wt%-water clathrate compound by adding additive, ethanol. This can lead to shorten refrigerator operation time of low temperature latent heat storage system and improve COP of refrigerator and efficiency of overall system. Therefore energy can be saved and efficiency can be improved much more.

TMA-물계 포접화합물의 과냉각 억제에 대한 연구 II (A Study on Supercooling Repression of TMA-Water Clathrate Compound II)

  • 김창오;김진흥;정낙규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2006년도 에너지.가스.기후변화학회 연합춘계학술대회 및 특별심포지움
    • /
    • pp.317-324
    • /
    • 2006
  • This study aims to find out cooling characteristics of TMA(Tri-Methyl-Amine, ($CH_{3})_{3}N$) 25wt%-clathrate compound with ethanol($CH_{3}CH_{2}OH$) such as supercooling, phase change temperature and specific heat. For this purpose, ethanol is added as per weight concentration and cooling experiment is performed at $-6{\sim}-8^{\circ}C$, cooling heat source temperature, and it leads the following result. (1) Phase change temperature is decreased due to freezing point depression phenomenon. Especially, it is minimized as $3.8^{\circ}C$ according to cooling source temperature in case that 0.5w% of ethanol is added. (2) If 0.5wt% of ethanol is added, average supercooling degree is $0.9^{\circ}C $ and minimum supercooling is $0.8,\;0.7^{\circ}C$ according to cooling heat source temperature. The restraint effect of supercooling is shown. (3) Specific heat shows tendency to decrease if ethanol is added. It is $3.013{\sim}3.048\;kJ/kgK$ according to cooling heat source temperature if 0.5wt% of ethanol is added. Phase change temperature higher than that of water and inhibitory effect against supercooling can be confirmed through experimental study on cooling characteristics of TMA 25wt%-water clathrate compound by adding additive, ethanol. This can lead to shorten refrigerator operation time of low temperature thermal storage system and improve COP of refrigerator and efficiency of overall system. Therefore energy can be saved and efficiency can be improved much more.

  • PDF

A/C 콘덴서를 포함한 차량냉각 성능예측에 관한 연구 (A Study on Prediction Method of Vehicle Cooling Performance with A/C Condenser)

  • 이상호;박정원
    • 한국자동차공학회논문집
    • /
    • 제10권3호
    • /
    • pp.51-60
    • /
    • 2002
  • An analysis method to predict performance of a vehicle cooling system which is composed of radiator, A/C condenser, cooling fan, and etc. is suggested. Air flow through the heat exchanger system and heat rejection rate which dominate the cooling performance are analyzed. Heat transfer with A/C refrigerant phase change is also considered in the analysis. Some predicted results are compared with experimental data for various operating conditions. This evaluation procedure will be useful for the design of optimal vehicle cooling system.

동력분산형 고속전철의 추진시스템용 냉각장치의 설계 연구 (Study on Design of the Cooling System Used for the Propulsion System of the High-Speed EMU)

  • 유성열;김성대;기재형;임광빈;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1221-1226
    • /
    • 2008
  • Present, the cooling method of using a phase-change heat transfer such as immersed type, heat pipe etc is applied in cooling of high-capacity power semiconductors of the main power system for the high speed train with the concentrated traction. In order to apply these phase-change cooling system to the high speed EMU to be developed, needed are technological researches of consideration of installing space, air passage, light weight material and miniaturization. Although this research establishes design specifications through theoretical analysis and computational analysis from the basic design process of the cooling system of the propulsion system for the high-speed EMU, when details design is completed, present improvement subject and optimum design before manufacturing the prototype of the cooling system on the basis of analysis results. And then, carried out will be the performance tests through prototype manufacture and reliability estimation by components of cooling system.

  • PDF

포접화합물의 냉각특성에 대한 첨가제의 영향 (The Effects of Additives on the Cooling Characteristic of a Clathrate Compound)

  • 김진흥;정낙규;김석현;김창오
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.125-130
    • /
    • 2005
  • This study was peformed to investigate the phase change temperature, the supercooling, the maintenance time of liquid phase and the change rate of volume of TMA 30 $wt\% clathrate compound with additives. TMA 30 $wt\% clathrate compound with additive was cooled at heat source temperature of $-6^{circ}C$. The additives are ethylene glycol and chloroform. Their concentration are 0.1$wt\% respectively. The experimental results showed that the phase change temperature was not affected by additives and this was average $5.3^{circ}C$. Also the supercooling and the maintenance time of liquid phase were decreased by additives. Especially, the average value of supercooling showed by $8.8^{circ}C$ and the maintenance time of liquid phase was by 19 minutes in the case of chloroform 0.1$wt\%. Additionally, the average change rate of volume showed by $1.26{\~}1.31\%$ according to additives and the volume was decreased by the phase change from liquid to solid.