• Title/Summary/Keyword: Phase variation

Search Result 2,042, Processing Time 0.035 seconds

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Electrochemical Study on Transfer Reaction of Ionizable Cefotiam across a Water/1,2-dichloroethane Interface and Drug Sensing Applications (물/1,2-Dichloroethane 계면에서 Cefotiam 약물 이온의 전이 반응 연구 및 약물 센서에 응용)

  • Liu, XiaoYun;Jeshycka, Shinta;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.29 no.5
    • /
    • pp.581-588
    • /
    • 2018
  • In this article, electrochemical investigation of the transfer reaction of ionizable cefotiam (CTM), an antibiotic molecule across a polarized water/1,2-dichloroethane (water/1,2-DCE) interface was studied. Ion partition diagram providing the preferred charged form of CTM in either water or 1,2-DCE phase was established via the voltammetric evaluation of the transfer process of differently charged CTM species depending upon the pH variation of aqueous solutions. Thermodynamic information including the formal transfer potential and formal Gibbs transfer energy values in addition to important pharmacokinetics including partition coefficients of ionizable CTM were also evaluated. In particular, the current associated with the transfer of CTM present at pH 3.0 aqueous solution proportionally increased with respect to the CTM concentration which was further used for developing CTM sensitive ion sensor. In order to improve the portability and convenient usage, a single microhole interface fabricated in a supportive polyethylene terephthalate film was used of which hole was filled with a polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel replacing 1,2-DCE, a toxic organic solvent. A dynamic range of $1-10{\mu}M$ CTM was obtained.

The Performance Comparison of the ISCA and MSCA Algorithm for Adaptive Equalization (적응 등화를 위한 ISCA와 MSCA 알고리즘의 성능 비교)

  • Lim, Seung-Gag;Kang, Dae-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.7-13
    • /
    • 2012
  • The performance of blind equalization algorithm ISCA was compared with MSCA that is used for the minimization of the inter symbol interference which occurs in the time dispersive communication channel for digital transmission. Because of the non-linearities of a magnitude and phase transfer characteristics of a communication channel, the transmitting signal will be received that band limited and time dispersived. Therefore the distortion was compensated by using the self adaptive equalizer at the receiving side, then passing through the detector for the decision of "1" or "0". At this time the Constellation Dependent Constant is played an important role in the adaptive equalizer used on the receiver. In order to calculation of this constant, the ISCA and MSCA was used the second order statistics. The ISCA and MSCA which are possible to compensation of mensioned transfer function simulataneously, are improved the performance of original SCA algorithm and then was compared the performance by computer simulation. For this, the recovered constellation, residual isi and MSE was used, and a result of performance comparison, the ISCA algorithm has better than the MSCA in every performance index. But on the steady state of equalizer, the variation of performance due to the CME terms in the MSCA equalization algorithm was less than the ISCA, so MSCA has better stability.

Active Object Tracking System based on Stereo Vision (스테레오 비젼 기반의 능동형 물체 추적 시스템)

  • Ko, Jung-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.4
    • /
    • pp.159-166
    • /
    • 2016
  • In this paper, an active object tracking system basing on the pan/tilt-embedded stereo camera system is suggested and implemented. In the proposed system, once the face area of a target is detected from the input stereo image by using a YCbCr color model and phase-type correlation scheme and then, using this data as well as the geometric information of the tracking system, the distance and 3D information of the target are effectively extracted in real-time. Basing on these extracted data the pan/tilted-embedded stereo camera system is adaptively controlled and as a result, the proposed system can track the target adaptively under the various circumstance of the target. From some experiments using 480 frames of the test input stereo image, it is analyzed that a standard variation between the measured and computed the estimated target's height and an error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 1.03 and 1.18% on average, respectively. From these good experimental results a possibility of implementing a new real-time intelligent stereo target tracking and surveillance system using the proposed scheme is finally suggested.

Manufacturing of Monodisperse Pectin Hydrogel Microfibers Using Partial Gelation in Microfluidic Devices (미세유체 장치에서 부분젤화법을 이용한 단분산성 펙틴 하이드로젤 미세섬유의 제조)

  • Jin, Si Hyung;Kim, Chaeyeon;Lee, Byungjin;Shim, Kyu-Rak;Kim, Dong Young;Lee, Chang-Soo
    • Clean Technology
    • /
    • v.23 no.3
    • /
    • pp.270-278
    • /
    • 2017
  • This study introduces a method to easily fabricate highly monodisperse pectin hydrogel microfibers in a microfluidic device by using partial gelation. The hydrodynamic parameters between the pectin aqueous solution and the calcium ions containing oil solution are precisely controlled to form a stable elongation flow of the pectin aqueous solution, and partial gelation of the pectin aqueous solution is performed by the chelating of the calcium ions at the interface between the two phases. The partially gelled pectin aqueous solution is phase-separated from the oil solution in an aqueous calcium chloride solution outside the microfluidic device and is completely gelled to produce monodisperse pectin hydrogel microfibers. The thickness of the pectin hydrogel microfiber is controlled in a reproducible manner by controlling the volumetric flow rate of the initially injected pectin aqueous solution. The pectin hydrogel microfibers were 200 to 500 micrometers in diameter and had a coefficient of variation below 5% under all thickness conditions, indicating that the pectin hydrogel microfibers produced by partial gelation are highly monodisperse. In addition, biomaterials can be immobilized to the pectin hydrogel microfibers produced by a single process, demonstrating the possibility that our pectin hydrogel microfiber can be used as carriers for biomaterials or tissue engineering.

Analytical Method for Flusulfamide as Benzenesulfonamide Fungicide, Residues in Major Agricultural Commodities (주요 농산물 중 Bezenesulfonamide계 살균제 Flusulfamide의 잔류 분석법)

  • Ahn, Kyung-Geun;Kim, Gi-Ppeum;Hwang, Young-Sun;Kang, In-Kyu;Lee, Young Deuk;Choung, Myoung-Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.1
    • /
    • pp.57-65
    • /
    • 2018
  • BACKGROUND: An analytical method was developed using HPLC-UVD/MS to precisely determine the residue of flusulfamide, a benzenesulfonamide fungicide used to inhibit spore germination. METHODS AND RESULTS: Flusulfamide residue was extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice, and soybean. The extract was diluted with large volume of saline water and directly partitioned into dichloromethane to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. On an octadecylsilyl column in HPLC, flusulfamide was successfully separated from co-extractives of sample, and sensitively quantitated by ultraviolet absorption at 280 nm with no interference. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop sample fortified with flusulfamide at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries ranged from 82.3 to 98.2% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of flusulfamide was 0.02 mg/kg as verified by the recovery experiment. A confirmatory method using LC/MS with selected-ion monitoring technique was also provided to clearly identify the suspected residue.

Simultaneous Determination of Aflatoxins and Ochratoxin A in Pork by LC-MS/MS (LC-MS/MS를 이용한 돼지고기 중 총아플라톡신 및 오크라톡신 A 동시분석법 확립)

  • Paek, Ockjin;Park, Songyi;Park, Ki Hun;Kim, Sheen-Hee;Suh, Saejung;Yoon, Hae Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.3
    • /
    • pp.194-200
    • /
    • 2016
  • Aflatoxins and ochratoxin A (AFTs and OTA) are secondary fungal metabolites produced by several moulds, mainly by Aspergillus flavus by Aspergillus ochraceus and Penicillium verrucosum, and these toxins can be transferred to animals and humans through the ingestion of contaminated feed and food. This study was to develop the analytical method for determination the levels of AFTs ($B_1$, $B_2$, $G_1$ and $G_2$) and OTA in pork. The AFTs and OTA were analyzed simultaneously by electrospray ionization in positive ion mode and mass reaction monitoring (MRM) after solid phase extract (SPE) columns clean-up. Performance characteristics, such as accuracy, precision, linear range, limit of detection (LOD) and quantification (LOQ), were also determined. Matrix-matched standard calibration was used for quantification, obtaining the recoveries in the range of 67.3~108.2% with the relative standard deviations of < 20%. Limits of detection and quantification were also estimated, obtaining the limits of quantification ranged in $0.7{\sim}1.3{\mu}g/kg$. The results of the inter-day study, which was performed with pork samples for 3 days, showed an accuracy of 92.0~109.9%. The precisions (expressed as relative standard deviation values) for the inter day variation were 2.6~17.8%. The method developed in this study was able to carry out the analysis with the satisfactory intensity and accuracy.

Effect of Sulphate on the Formation of $C_3S$ and Its Properties ($C_3S$의 生成反應 및 特性에 미치는 黃酸鹽의 影響)

  • 김병권;최상흘;한기성
    • Journal of the Korean Ceramic Society
    • /
    • v.25 no.3
    • /
    • pp.207-216
    • /
    • 1988
  • Effect of $SO_3$ on the formation of $C_3S$ and its properties were investigated through studies for diffusion of reacting component, the size variation of $C_3S$ and compositional change of the phases in the clinker. When less than 2.0% of $SO_3$ was added to the clinker composition, the formation of $C_3S$ was enhanced, however, addition of more than 2.0% of $SO_3$ rather restrained the reaction remarkably. The diffusion coefficient of Si into the melt was about $3.6~4.2{\times}10^{-7}Cm^2$/sec and it was slightly decreased with the amount of $SO_3$. The crystal size of $C_3S$ formed in the clinker was grown gradually according to the amount of $SO_3$, when more than 1.0% of $SO_3$ was added. With increasing of $SO_3$ content in the clinker composition of CaO and decreasing of $SiO_2$ were found in the melt of the clinker. Consequently, it is considered that the decreasing of $C_3S$ formation is caused by dissolution and transportation of CaO component into liquid phase is interrupted.

  • PDF

Assessment of Radionuclide Deposition on Korean Urban Residential Area

  • Lee, Joeun;Han, Moon Hee;Kim, Eun Han;Lee, Cheol Woo;Jeong, Hae Sun
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.101-107
    • /
    • 2020
  • Background: An important lesson learned from the Fukushima accident is that the transition to the mid- and long-term phases from the emergency-response phase requires less than a year, which is not very long. It is necessary to know how much radioactive material has been deposited in an urban area to establish mid- and long-term countermeasures after a radioactive accident. Therefore, an urban deposition model that can indicate the site-specific characteristics must be developed. Materials and Methods: In this study, the generalized urban deposition velocity and the subsequent variation in radionuclide contamination were estimated based on the characteristics of the Korean urban environment. Furthermore, the application of the obtained generalized deposition velocity in a hypothetical scenario was investigated. Results and Discussion: The generalized deposition velocities of 137Cs, 106Ru, and 131I for each residence type were obtained using three-dimensional (3D) modeling. For all residence types, the deposition velocities of 131I are greater than those of 106Ru and 137Cs. In addition, we calculated the generalized deposition velocities for each residential types. Iodine was the most deposited nuclide during initial deposition. However, the concentration of iodine in urban environment drastically decreases owing to its relatively shorter half-life than 106Ru and 137Cs. Furthermore, the amount of radioactive material deposited in nonresidential areas, especially in parks and schools, is more than that deposited in residential areas. Conclusion: In this study, the generalized urban deposition velocities and the subsequent deposition changes were estimated for the Korean urban environment. The 3D modeling was performed for each type of urban residential area, and the average deposition velocity was obtained and applied to a hypothetical accident. Based on the estimated deposition velocities, the decision-making systems can be improved for responding to radioactive contamination in urban areas. Furthermore, this study can be useful to predict the radiological dose in case of large-scale urban contamination and can support decision-making for long-term measurement after nuclear accident.

A New Height Estimation Scheme Using Geometric Information of Stereo Camera based on Pan/tilt control (팬/틸트 제어기반의 스데레오 카메라의 기하학적 정보를 이용한 새로운 높이 추정기법)

  • Ko Jung-Hwan;Kim Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.156-165
    • /
    • 2006
  • In this paper, a new intelligent moving target tracking and surveillance system basing on the pan/tilt-embedded stereo camera system is suggested and implemented. In the proposed system, once the face area of a target is detected from the input stereo image by using a YCbCr color model and phase-type correlation scheme and then, using this data as well as the geometric information of the tracking system, the distance and 3D information of the target are effectively extracted in real-time. Basing on these extracted data the pan/tilted-imbedded stereo camera system is adaptively controlled and as a result, the proposed system can track the target adaptively under the various circumstance of the target. From some experiments using 480 frames of the test input stereo image, it is analyzed that a standard variation between the measured and computed the estimated target's height and an error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 1.03 and 1.18$\%$ on average, respectively. From these good experimental results a possibility of implementing a new real-time intelligent stereo target tracking and surveillance system using the proposed scheme is finally suggested.