• Title/Summary/Keyword: Phase variation

Search Result 2,038, Processing Time 0.029 seconds

Experimental and Analytical Study on the Bus Duct System for the Prediction of Temperature Variations Due To the Fluctuation of Load

  • Thirumurugaveerakumar, S.;Sakthivel, M.;Valarmathi, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2036-2041
    • /
    • 2014
  • In this paper, a thermal model is developed for the bus bar system to predict the temperature variation during the transient time period and to calculate both the steady-state and transient electrical current carrying capacity (ampacity) of bus bar. The bus bar system installed in the power house of Kumaraguru College of Technology, Coimbatore has been considered. Temperature variation predicted in the modelling is validated by observing the current and steady state temperatures in different feeders of the bus bar. Magnetic field of the extreme phases R and B induces more current in the middle phase Y. Hence, the steady state temperature in the phase Y is greater than other two phases. The transient capabilities of the bus bar are illustrated by calculating the variations in the bus bar temperature when it is subjected to a step change in current during the peak hours due to increase in hostel utilities and facilities (5.30 pm to 10.30 pm). The physical and geometrical properties of the bus bar and temperature variation in the bus bar are used to estimate the thermal time constants for common bus bar cross-sections. An analytical expression for the time constant of the bus bar is derived.

Reduction of DC-Link Voltage Ripple of Three-phase AC/DC Converter for Uninterruptible Power Supply by Applying Fuel Cell (연료전지를 적용한 무정전전원장치용 3상 AC/DC 컨버터의 DC-Link 전압 리플 저감)

  • Park, Jin-Ho;Kim, Kyung-Min;Lee, Jung-Hyo;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.43-51
    • /
    • 2010
  • Conventional UPS(Uninterruptible Power Supply) using batteries for assisting the source is limited by the large volume and the life-time of battery. Moreover, voltage variation caused by the sudden load variation brings the problems on UPS system output. In this paper, the battery using fuel cell which is environment-friendly alternative energy is connected on AC/DC converter for UPS to compensate the sudden load variation energy and make the stable power.

Annual Variation of Salinity in the Neighbouring Seas of Korea (韓國周邊 海洋鹽分의 年變化)

  • Kang, Yong Q;Jin, Myoung-Shin
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.105-110
    • /
    • 1984
  • We study the annual variation of salinity at the sea surface and at 30m depth in the neighbouring seas of korea by the harmonic method. The analysis based on the monthly salinity data at 182 stations collected regularly by the Fisheries Research and Development Agency during 15 years (1961∼1975). The annual mean salinity in the West Sea is lower than that in the East Sea. In the amplitude of annual salinity variation decreases and the phase delays with the downstream distance of the Tsushima Current. The salinity at 30m has a higher mean, a smaller amplitude and a delayed phase than the corresponding ones at the surface. The annual variations of salinity in the South and East Seas are caused mainly by the annual variations of the local precipitation and that of the fresh water discharge from the Yangtze River.

  • PDF

An analytical approach of behavior change for concrete dam by panel data model

  • Gu, Hao;Yang, Meng;Gu, Chongshi;Cao, Wenhan;Huang, Xiaofei;Su, Huaizhi
    • Steel and Composite Structures
    • /
    • v.36 no.5
    • /
    • pp.521-531
    • /
    • 2020
  • The behavior variation of concrete dam is investigated, based on a new method for analyzing the data model of concrete dam in service process for the limitation of wavelet transform for solving concrete dam service process model. The study takes into account the time and position of behavior change during the process of concrete dam service. There is no dependence on the effect quantity for overcoming the shortcomings of the traditional identification method. The panel data model is firstly proposed for analyzing the behavior change of composite concrete dam. The change-point theory is used to identify whether the behavior of concrete dams changes during service. The phase space reconstruction technique is used to reconstruct the phase plane of the trend effect component. The time dimension method is used to solve the construction of multi-transformation model of composite panel data. An existing 76.3-m-high dam is used to investigate some key issues on the behavior change. Emphasis is placed on conversion time and location for three time periods consistent with the practical analysis report for evaluating the validity of the analysis method of the behavior variation of concrete dams presented in this paper.

Instantaneous Control of a Single-phase PWM Converter Considering the Voltage Ripple Estimate (전압 리플 추정을 고려한 단산 PWM 컨버터의 순시치 제어)

  • 김만기;이우철;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.27-33
    • /
    • 1997
  • In this paper, instantaneous controller of a single-phase PWM converter is realized using DSP. The stable PI gain of the input current and the DC link voltage control system is designed. The DC link voltage control system can be designed in continuous-time domain. But as for the input current control system, the descretizing effect cannot be ignored so it must be designed in descrete-time domain considering the calculation time. The capacitance estimating algorithm which can be acquired through the ripple voltage is proposed. By this algorithm the DC link capacitance can be estimated even under the transient state. Experimental results show the input power factor of 99.1% and the voltage variation rate of $\pm$5% according to the load variation.

  • PDF

Analysis of unsteady temperature distribution in a cylinder for rifle barrel disign (원통형 용기의 비정상온도해석)

  • ;;;Lee, Hung Joo
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.4
    • /
    • pp.173-180
    • /
    • 1979
  • Temperature distriburion in a hollow chlinder has been analyzed mathematically. Unsteady condition considered assumed a constant heat flux input from the inside. The results are compared with experimental results of surface temperature rise of a gun barrel during continuous firing. Their agreements are acceptable. Effects of various dimensionless parameters on the surface temperature rise are discussed. For small Biot numbers, the external survface temperature approaches more rapidly to the steady temperature. Temperature difference between internal and external surfaces becomes greater for small Biot number. Steady solution assumed that the gas temperature inside the cylinder varies periodically. Relative amplitude and phase angles between the gas temperature and the internal or external surface temperature are obtained. Phase angles become smaller for large radiancy of gas temperature variation, small external Biot number, or large internal biot number. Relative amplitudes become samller as radiancy of gas temperature variation and internal Biot number become smaller. or external Biot number becomes larger. The solution obtained in this paper can be applied to gun barrels, heat pipes used in heat excangers, and reciprocation engines.

A Study Compensation Method for Dynamic Characteristics in Electro-Hydraulic Servosystem Equipping Load Pressure Feedback Compensator (부하압력 피이드백 보상기를 장착한 전기-유압서보계의 동특성 개선에 관한 연구)

  • Kim, Jong-Kyum
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.1
    • /
    • pp.126-136
    • /
    • 1992
  • In this paper, a simple structured feedback compensation scheme for a electro-hydraulic servo system to keep the response characteristics unchanged regardless of the load variation is proposed. In electro-hydraulic servo system, servovalve is most important control element. But the relation between input corrent and output flowrate of the servovalve has properties as follows; firstly, in spite of constant input current, output flowrate decreases as load pressure increases, secondly, according to frequency response of typical servovalve, the characteristics of gain and phase shift is something like 2'nd order system. Load pressure feedback compensation method has been applied to eliminate the first influence, the second influence has been improved by phase lead compensation method. As a result of above compensation methods, regardless of variation load condition, spring and inertia load, the compensation scheme has been verified to be effective within the range of frequency less than 25Hz by static response and dynamic response in time domain and frequency domain through experiments.

  • PDF

DC-link Voltage Ripple Compensation Method for Single Phase 3-level PWM Converters (단상 3-레벨 PWM 컨버터를 위한 중성점 전압 변동 보상 기법)

  • Lee, Hee-Myun;Lee, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.8-15
    • /
    • 2013
  • This paper proposes a DC-link voltage variation compensation method for a 3-level single phase converter for high-speed trains. Since 3-level NPC(Neutral Point Clamped) type converters have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, reducing the voltage difference between the top and bottom capacitors is required. In this paper, compensation time proportional to the voltage difference is added to PWM switching time to solve the voltage variation. The compensation time is obtained by a PI controller. Simulation results demonstrate the validity of the proposed method.

Properties of CuInSe$_2$ Films Prepared by Selenization of Sputtered Cu/In (Sputter 증착된 Cu/In을 Selenization 하여 얻은 CuInSe$_2$ 박막의 특성)

  • 김선재;임호빈
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.3-6
    • /
    • 1991
  • CuInSe$_2$ films have been prepared by selenium vapor annealing of sputtered Cu/In layer. The properties of selenized CuInSe$_2$films have been studied as a function of selenization temperature for two sputtered thicknesses. A large indium loss occurs in the sputtered Cu/In layer during the selenization. The indium loss with the selenization temperature is confirmed by the increase in the amount of CuxSe phase at lower temperature and the decrease in the crystallinity of chalocpyrite CuInSe$_2$phase at higher temperature. The variations of the electrical properties in the selenized films with the selenization conditions are due primarily to the variation of hole concentration. The variation of the hole concentration can be explanined by the indium loss away the sputtered Cu/In layer.

Improvement of Current Controller Characteristics of Interior Permanent Magnet Synchronous Motor for Electric Vehicle (전기자동차용 매입형 영구자석 동기전동기의 전류제어기 특성 개선)

  • Park, Jung-Woo;Kim, Jong-Moo;Ku, Dae-Hyun;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2526-2528
    • /
    • 1999
  • Parameters of equivalent circuit of IPMSM are varied according to current magnitude and current phase angle. Especially, Parameter variation of IPMSM for an electric vehicle(EV) is critical. Because current magnitude is very large. and current phase angle range also is wide. So, variation characteristics of $L_d$ and $L_q$ of the IPMSM are analyzed and verified through experiments. And then new parameter estimator of $L_d$ and $L_q$ that is constructed by neural network technique is suggested Using numerical method, the advanced characteristics of current controller of vector control algorithm is verified.

  • PDF