• 제목/요약/키워드: Phase switch

검색결과 521건 처리시간 0.023초

Control of Three-Phase Three-Switch Buck-Type Rectifier in EV Rapid Charging Systems

  • Chae, Beomseok;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.189-190
    • /
    • 2015
  • This paper investigates an economic and highly efficient power converter topology and its modulation scheme for 60kW rapid EV charger system. The target system consists of three-phase three-switch buck-type rectifier topology. A new Carrier Based PWM scheme along with its simple implementation using logic gates is introduced in this paper. This PWM scheme replaces the diode rectifier equivalent switching state with an active switching state producing the effectively same current flowing path. As a result, the distortion of input current during the polarity reversal of capacitor line voltage can be mitigated. The proposed modulation technique is confirmed through simulation verification. The proposed modulation technique and its implementation scheme can expand the operation range of the three-phase three-switch buck-type rectifier having ac input and capacitor ripple current of high quality.

  • PDF

고조파 주입법에 의한 3상 부스트 정류기의 고조파 저감 (Harmonic Reduction of a Single-Switch Three-Phase Boost Rectifier using Harmonic-Injection Method)

  • 이준구;박석하;김진성;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.134-136
    • /
    • 1998
  • In this paper, we present harmonic reduction of a Single-Switch Three-Phase Boost Rectifier which is operated at 25kHz. A simulation result shows that input current harmonics of Single-Switch Three-Phase Rectifier are reduced by Harmonic-Injection Method. Sixth harmonic is used for Harmonic-Injection Method.

  • PDF

Three phase flow simulations using the fractional flow based approach with general initial and boundary conditions

  • Suk, Heejun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.88-91
    • /
    • 2004
  • The multiphase flow simulator, MPS, is developed based on the fractional flow approach considering tile fully three phase flow with general initial and boundary condition. Most existing fractional flow-based models are limited to two-phase flow and specific boundary conditions. Although there appears a number of three-phase flow models, they were mostly developed using pressure based approaches. As a result, these models require cumbersome variable-switch techniques to deal with phase appearance and disappearance. The use of fractional flow based approach in MPS makes it unnecessary to use variable-switch to handle the change of phase configurations. Also most existing fractional flow based models consider only specific boundary conditions. However, the present model considers general boundary conditions of most possible and plausible cases which consists of ten cases.

  • PDF

원칩 마이컴을 이용한 단상유도전동기의 주권선 제어에 관한 연구 (A Study on the Main Winding Control of Single Phase Induction Motor using One-Chip Micom)

  • 박수강;백형래
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권1호
    • /
    • pp.70-76
    • /
    • 2000
  • This paper describes a one-chip micom controller and phase angle control method for self-starting and energy saving of single-phase induction motor. The proposed method is based on the optimal efficiency control which is running by variable phase angle of main winding current such as to maintain the maximum efficiency characteristics of the motor, in voltage control with TRIAC. Experiments are focused on a capacitor starting single-phase induction motor. The optimal energy saving by variable phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Utility-Interactive Four-Switch Three-Phase Soft-Switching Inverter with Single Resonant DC-Link Snubber and Boost Chopper

  • Ahmed, Tarek;Nagai, Shinichiro;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.109-117
    • /
    • 2007
  • In this paper, a novel proposal for a utility-interactive three-phase soft commutation sinewave PWM power conditioner with an auxiliary active resonant DC-link snubber is developed for fuel cell and solar power generation systems. The prototype of this power conditioner consists of a PWM boost chopper cascaded three-phase power conditioner, a single two-switch auxiliary resonant DC-link snubber with two electrolytic capacitors incorporated into one leg of a three-phase V-connection inverter and a three-phase AC power source. The proposed cost-effective utility-interactive power conditioner implements a unique design and control system with a high-frequency soft switching sinewave PWM scheme for all system switches. The operating performance of the 10 kW experimental setup including waveform quality, EMI/RFI noises and actual efficiency characteristics of the proposed power conditioner are demonstrated on the basis of the measured data.

3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상 (DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive)

  • 박상훈;윤용호;이병국;이수원;원충연
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.

Diagnosis Methods for IGBT Open Switch Fault Applied to 3-Phase AC/DC PWM Converter

  • Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.120-127
    • /
    • 2012
  • Fault diagnosis technique of electrical drives is becoming more and more important, since voltage fed converter system has become industrial standard in many applications. Many studies have been conducted an inverter fault diagnosis for induction motors. However, there are few researches about fault diagnosis of 3-phase ac/dc PWM (Pulse Width Modulation) converter compared to the dc/ ac inverter. The ac/dc converter is the opposite of dc/ac inverter at current flow. Also, inverter and converter have different current patterns under the same condition of IGBT (Insulated gate bipolar transistor) open switch fault. Therefore, it is difficult to apply intact diagnosis methods of inverter to the converter. This paper proposes modified fault detection methods for IGBT open switch fault in 3-phase ac/dc PWM converter by modifying established fault diagnostic methods for dc/ac inverters.

PRRA로 제안된 ATM Switch 설계 (A Design of Proposed ATM Switch using PRRA)

  • Seo, In-Seok
    • 한국컴퓨터정보학회논문지
    • /
    • 제7권2호
    • /
    • pp.115-123
    • /
    • 2002
  • 본 논문은 중재기가 제공되는 새로운 타입의 입출력 버퍼 ATM스위치를 제안하고 다양한 트래픽 상태하에서 그 성능을 연구하였다. 제안된 스위치는 PRI 신호를 제어할 수 있는 중재기의 구조와 특성을 최대한 활용하기 위한 목적으로 설계되었다. 제안된 스위치의 기본적인 목적은 간단한 입력 버퍼 스위치에 발생하는 HOL블록킹 현상을 제거 또는 적어도 최소화하는 것이다. 여러 가지 HOL 중재 알고리즘들이 이러한 목적으로 논문을 통해 제안되었다. 제안된 스위치에서는 중재기와 출력단에 버퍼를 이용하여 HOL 블록킹 현상의 억제를 효과적인 방식으로 시도하였다. 중재기는 다수의 잘 알려진 HOL 조정 알고리즘 중에서 Three Phase Algorithm을 사용하도록 설계되었다. 제안된 스위치는 REQ신호를 통하여 우선 전송의 제어를 요청, 이 신호를 중재기로 전송함으로써 중재기는 입력 버퍼로부터 전송된 신호를 제어한다. 컴퓨터 시뮬레이션 결과는 균일 트래픽 상태하에서 제안된 스위치의 효과를 설명하기 위해 제공하였다.

  • PDF

고속 네트워크를 위한 ATM Switch 설계 (A Design of ATM Switch for High Speed Network)

  • Seok, Seo-In;Kuk, Cho-Sung
    • 한국컴퓨터정보학회논문지
    • /
    • 제8권2호
    • /
    • pp.97-105
    • /
    • 2003
  • 본 논문은 중재기가 제공되는 새로운 타입의 입출력 버퍼 ATM스위치를 제안하고 다양한 트래픽 상태하에서 그 성능을 연구하였다. 제안된 스위치는 PRI 신호를 제어할 수 있는 중재기의 구조와 특성을 최대한 활용하기 위한 목적으로 설계되었다. 제안된 스위치의 기본적인 목적은 간단한 입력 버퍼 스위치에서 발생하는 HOL 블록킹 현상을 제거하거나, 적어도 줄일 수 있도록 하는 것이다. 여러 가지 HOL 중재 알고리즘들이 이러한 목적으로 논문을 통해 제안되었다. 제안된 스위치에서는 중재기와 출력단에 버퍼를 이용하여 HOL 블록킹 현상의 억제를 효과적인 방식으로 시도하였다. 중재기는 다수의 잘 알려진 HOL 조정 알고리즘 중에서 Three Phase Algorithm을 사용하도록 설계되었다 제안된 스위치는 REQ신호를 통하여 우선 전송의 제어를 요청, 이 신호를 중재기로 전송함으로써 중재기는 입력 버퍼로부터 전송된 신호를 제어한다. 컴퓨터 시뮬레이션 결과는 비균일 random 트래픽 상태 하에서 제안된 스위치의 효과를 설명하기 위해 제공하였다.

  • PDF

Model-based Optimal Control Algorithm for the Clamp Switch of Zero-Voltage Switching DC-DC Converter

  • Ahn, Minho;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.323-333
    • /
    • 2017
  • This paper proposes a model-based optimal control algorithm for the clamp switch of a zero-voltage switching (ZVS) bidirectional DC-DC converter. The bidirectional DC-DC converter (BDC) can accomplish the ZVS operation using the clamp switch. The minimum current for the ZVS operation is maintained, and the inductor current is separated from the input and output voltages by the clamp switch in this topology. The clamp switch can decrease the inductor current ripple, switching loss, and conduction loss of the system. Therefore, the optimal control of the clamp switch is significant to improve the efficiency of the system. This paper proposes a model-based optimal control algorithm using phase shift in a micro-controller unit. The proposed control algorithm is demonstrated by the results of PSIM simulations and an experiment conducted in a 1-kW ZVS BDC system.