• Title/Summary/Keyword: Phase scaling factor

Search Result 9, Processing Time 0.133 seconds

The Design of IMC-PID Controller Considering a Phase Scaling Factor (위상 조절 인자를 고려한 IMC-PID 제어기의 설계)

  • Kim, Chang-Hyun;Lim, Dong-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1618-1623
    • /
    • 2008
  • In this paper, a new design method for IMC-PID that adds a phase scaling factor of system identifications to the standard IMC-PID controller as a control parameter is proposed. Based on analytically derived frequency properties such as gain and phase margins, this tuning rule is an optimal control method determining the optimum values of controlling factors to minimize the cost function, integral error criterion of the step response in time domain, in the constraints of design parameters to guarantee qualified frequency design specifications. The proposed controller improves existing single-parameter design methods of IMC-PID in the inflexibility problem to be able to consider various design specifications. Its effectiveness is examined by a simulation example, where a comparison of the performances obtained with the proposed tuning rule and with other common tuning rules is shown.

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.

New Optimal Tuning Method of IMC-PID for SI/SO Systems (단일 입출력 시스템에 대한 IMC-PID의 새로운 최적 동조법)

  • Kim, Chang-Hyun;Lim, Dong-Kyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.213-217
    • /
    • 2008
  • In this paper, a new design method for IMC-PID that adds a phase scaling factor of system identifications to the standard IMC-PID controller as a control parameter is proposed. Based on analytically derived frequency properties such as gain, phase margin and maximum magnitude of sensitivity function, this tuning rule is an optimal control method determining the optimum values of controlling factors to minimize the cost function, integral error criterion of the step response in time domain, in the constraints of design parameters to guarantee qualified frequency design specifications. The proposed controller improves existing single-parameter design methods of IMC-PID in the inflexibility problem to be able to consider various design specifications. Its effectiveness is examined by a simulation example, where a comparison of the performances obtained with the proposed tuning rule and with other common tuning rules is shown.

  • PDF

Theoretical Analysis of Phase Detector Technique for the Measurement of Cell Membrane Capacitance During Exocytosis (세포외 분비시 막 캐패시턴스를 측정하기 위한 위상감지법(phase detector technique)의 이론적 분석.)

  • Cha, Eun-Jong;Goo, Yong-Sook;Lee, Tae-Soo
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.43-57
    • /
    • 1992
  • Phase detector techique provides a unique probe to membrane recycling phenomenon by enabling dynamic monitoring of cell membrane capacitance. However, it has inherent errors due to constant changes in measurement environments. The present study analyzed several error sources to develope application criteria of this technique. and the following was found based on a theoretical analysis. The initial phase angle has to be appropriately selected to minimize the error due to perturbation of access and membrane conductances. Excitation frequency is also important to determine the initial phase angle. However. deviation of the phase angle from a predetermined initial value during the measurement period does not affect capacitance estimation to a significant degree. Despite an appropriate initial phase selection an error in scaling factor is expected for a large increase in capacitance during exocytosis. which may be overcome by iteratively correcting the scaling factor over the measurement period. These results will provide a useful guideline in practical application of this technique.

  • PDF

A Lock-Time Improvement for an X-Band Frequency Synthesizer Using an Active Fast-Lock Loop Filter

  • Heo, Yun-Seong;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.2
    • /
    • pp.105-112
    • /
    • 2011
  • In phase-locked frequency synthesizers, a fast-lock technique is frequently employed to overcome the trade-off between a lock-time and a spurious response. The function of fast-lock in a conventional PLL (Phased Lock Loop) IC (Integrated Circuit) is limited by a factor of 16, which is usually implemented by a scaling of charge pumper, and consequently a lock time improvement of a factor of 4 is possible using the conventional PLL IC. In this paper, we propose a novel external active fast-lock loop filter. The proposed loop filter provides, conceptually, an unlimited scaling of charge pumper current, and can overcome conventional trade-off between lock-time and spur suppression. To demonstrate the validity of our proposed loop-filter, we fabricated an X-band frequency synthesizer using the proposed loop filter. The loop filter in the synthesizer is designed to have a loop bandwidth of 100 kHz in the fast-lock mode and a loop bandwidth of 5 kHz in the normal mode, which corresponds to a charge pumper current change ratio of 400. The X-band synthesizer shows successful performance of a lock-time of below 10 ${\mu}sec$ and reference spur suppression below -64 dBc.

3-D Profilometry by Phase Shifting Profilometry (위상이동법을 이용한 3차원 형상측정법의 연구)

  • 오동석;남기봉
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 1994
  • We investigated the properties of various methods of 3 dimensional profilometry to choose the phase shifting technique for the reconstruction of the shape of a given specimen. The pattern was generated by a Twyman-Green interferometer and a PZT was used to shift the fringes on the target surface. The shape was calculated with Hariharan algorithm within the uncertainty of a scaling factor. The optical noise inherent in the laser source was observed to influence the final outcome to a great extent and the need for an exact calibration was noted. noted.

  • PDF

Analysis and solution to the phase concentration and DC-like component of correlation result in Daejeon correlator (대전 상관기의 상관 결과에 나타난 유사 DC 성분과 위상 집중 현상에 대한 원인 분석과 해결 방법)

  • Roh, Duk-Gyoo;Oh, Se-Jin;Yeom, Jae-Hwan;Oh, Chung-Sik;Jung, Jin-Seung;Chung, Dong-Kyu;Yun, Young-Joo;Oyama, Tomoaki;Ozeki, Kensuke;Onuki, Hirofumi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.3
    • /
    • pp.191-204
    • /
    • 2013
  • In this paper, we investigated the correlation outputs of Daejeon correlator at the viewpoints of the buffer memory setting related to the fine delay tracking and the under/overflow issue in FFT modules, in order to eliminate DC-like component and phase concentration to 0 degree. As the ring buffer memory is being used for the fine delay tracking, the DC-like component in correlation outputs is generated by improper setting of data read/write address, and then that address setting method is modified to exclude a polluted FFT segment in correlation processing when crossing the port/stream boundary. The phase concentration to 0 degree at beginning of bandpass is caused by inadequate scaling factors, which may be the origins of under/overflow occurred at internal computation of FFT stage. With the revised method of the ring buffer memory setting and the scaling factors in FFT, we could obtain higher signal-to-noise ratio and flux density, compared to the previous method, through the correlation processing of true observational data.

Cyclic Shift Based Tone Reservation PAPR Reduction Scheme with Embedding Side Information for FBMC-OQAM Systems

  • Shi, Yongpeng;Xia, Yujie;Gao, Ya;Cui, Jianhua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.8
    • /
    • pp.2879-2899
    • /
    • 2021
  • The tone reservation (TR) scheme is an attractive method to reduce peak-to-average power ratio (PAPR) in the filter bank multicarrier with offset quadrature amplitude modulation (FBMC-OQAM) systems. However, the high PAPR of FBMC signal will severely degrades system performance. To address this issue, a cyclic shift based TR (CS-TR) scheme with embedding side information (SI) is proposed to reduce the PAPR of FBMC signals. At the transmitter, four candidate signals are first generated based on cyclic shift of the output of inverse discrete Fourier transform (IDFT), and the SI of the selected signal with minimum peak power among the four candidate signals is embedded in sparse symbols with quadrature phase-shift keying constellation. Then, the TR weighted by optimal scaling factor is employed to further reduce PAPR of the selected signal. At the receiver, a reliable SI detector is presented by determining the phase rotation of SI embedding symbols, and the transmitted data blocks can be correctly demodulated according to the detected SI. Simulation results show that the proposed scheme significantly outperforms the existing TR schemes in both PAPR reduction and bit error rate (BER) performances. In addition, the proposed scheme with detected SI can achieve the same BER performance compared to the one with perfect SI.

The study on bioaccumulation of heavy metals in the cultured Pacific oyster, Crassostrea gigas, along the coast of Tongyeong, Korea (통영연안 해역의 양식 참굴 (Crassostrea gigas) 의 중금속 농축에 관한 연구)

  • Cho, Sang-Man;Kim, Yeong-Hwan;Jeong, Woo-Geon
    • The Korean Journal of Malacology
    • /
    • v.25 no.3
    • /
    • pp.213-222
    • /
    • 2009
  • In order to investigate contamination of heavy metal in seawater and cultured oyster, samples were collected November 2003 to July 2004 from 12 sites (13 sites for seawater) along the coast of Tongyeong, Korea. The mean concentrations of metal in oyster tissues were as follows: 0.09 (0.01-0.3) ${\mu}g/l$ for Cd, 0.47 (0.01-1.4) ${\mu}g/l$ for Cr, 0.59 (0.2-2.3) ${\mu}g/l$ for Ni, 1.02 (0.1-4.2) ${\mu}g/l$ for Pb and 0.48 (0.01-3.9) ${\mu}g/l$ for Hg in the seawater, whereas 2.45 (0-5.47) mg/kgDW for Cd, 3.63 (0.10-12.91) mg/kgDW for Cr, 3.2 (0.01-15.73) mg/kgDW for Ni, 3.51 (0.01-6.47) mg/kgDW for Pb and 0.39 (0.004-0.74) mg/kgDW for Hg, respectively. Most metal concentration values were below the permissible range for the related regulations. Mean bioconcentration factors (BCF) for each metal were as follows: 38,964 (1,771-207, 171) for Cd, 9,583 (1,231-80, 162) for Cr, 191 (3-20, 980) for Ni, 1,416 (245-5, 207) for Pb and 180 (5-716) for Hg, respectively. The BCF values from this study corresponded to the transitional phase from the pristine to the contaminated waters. Notably, Cd showed the highest BCF, which suggest that the Pacific oyster could be utilized as a useful biomarker for Cd contamination in sea water. The multidimensional scaling analysis suggested that the metal contaminants are mainly originated from combustion of fossil fuel and accumulated to oyster through food web.

  • PDF