• Title/Summary/Keyword: Phase method

Search Result 13,710, Processing Time 0.041 seconds

A Study on the AC Pow a Study on the AC Power Control Circuit by Combining PWM and Phase Control (PWM과 입상제어의 조합에 의한 교류전력 제어회로에 관한 연구)

  • 정화균;김이곤;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.2
    • /
    • pp.84-95
    • /
    • 1991
  • Mostly, phase control method is used to control the single phase AC power. The phase control method has some advantages such as ease to control and simple configuration. But the retardation of firing angle causes a lagging current even if load is purely resistive. So phase control causes a lagging power factor and a low efficiency at the input side in comparing with the system without switching device. A new PWM control method which can improve these defects for single phase AC power control circuit is proposed in this paper. The performances of the single phase AC power control circuit using the proposed method was investigated theoretically. Both power factor and waveform of load current can be improved better than those of the conventional methods.

  • PDF

A Study on $90^{\cire}$ Constant Phase Shifter (전송선형 $90^{\cire}$ 정위상기에 관한 연구)

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.6
    • /
    • pp.12-15
    • /
    • 1976
  • This paper presents the realization method of 90$^{\circ}$ constant phase shifter in the VHF band, constructed by the entirely differens idea from the conventional method of the realization of constant phase shifter in the audio frequency range. The construction of 90$^{\circ}$ constant phase shifter is. simple and can be easily realized by using the distributed constant element, transmission line, and the lumped constant elements, R,C,L.

  • PDF

Output Phase Synchronization Method of Inverter for Parallel Operation of Uninterruptible Power System (무정전전원장치 병렬운전을 위한 인버터의 출력 위상 동기화 방법)

  • Kim, Heui-Joo;Park, Jong-Myeon;Oh, Se-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.3
    • /
    • pp.235-241
    • /
    • 2020
  • In this paper, we propose the bus/bypass synchronization phase lock loop (B-Sync PLL) method using each phase voltage controller of a parallel UPS inverter. The B-Sync PLL included in each phase voltage control system of parallel UPS inverters has the transient response and the phase synchronization error at grid normal or blackout. The validity of this method is verified by simulation and experiment. As a result, the parallel UPS inverters using the proposed method confirmed that the output phase was continuously synchronized when a grid blackout, improving the transient response characteristics for stable load power supply and equal load sharing.

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정을 통한 3상 컨버터 센서리스 제어)

  • Chu, Hung-Seok;Park, Sung-Jun;Kim, Kwong-Tae;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1233-1235
    • /
    • 2000
  • A new control method of three phase converter without measuring input phase-voltage and DC-link voltage is proposed. Input phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In addition, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage (전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어)

  • Chu Hung-Seok;Cheon Chang-Gun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.227-230
    • /
    • 2001
  • A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF

Intervening Firing Method and Passive Filter Design for Harmonic Elimination and Reactive Power Compensation in Three-Phase Thyristor Phase-Controlled Converters Supplying a DC Motor

  • Pattanapongchai, Artite;Wongtongdee, Surached W.;Laohasongkram, Piphat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.813-816
    • /
    • 2005
  • This paper presents a method for harmonic elimination and reactive power compensation using an intervening firing method and passive power filter with is suitable to compensate rapidly changing loads and reactive power. The proliferation of three-phase thyristor phase-controlled converter of DC motor drives into a power system has the potential to increase the harmonic levels in the power system. The design procedure of an intervening firing method and passive power filter capable of reducing the voltage and current harmonics produced by converter supplied from a source having internal large inductive impedance is offered. The analysis uses the or CAD PSpice to model three-phase thyristor phase-controlled converter of DC motor drives as well as the system.

  • PDF

IT Innovativeness Evaluation considering the Adoption Phase : The Mongolian Case in Early-Adoptive Phase (도입단계를 고려한 IT혁신성 평가 : 몽골사례를 중심으로)

  • Lee, Jong Moo;Park, Ho In;Kim, Mahn Sool
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.1
    • /
    • pp.127-141
    • /
    • 2011
  • This paper provides a method to evaluate the competitiveness based on IT innovativeness considering the adoption phase and shows how to apply the method with a case of foreign market in the early-adoptive phase. The proposed method considers a variety of corporate and market characteristics concerned with the technology adoption, and it consists of several internal and external impacting factors that can influence the level of IT diffusion. Main advantage of this method is the ease of its applicability that allows evaluating the innovativeness, regardless of corporate size, industry type, or level of technology adoption. Therefore, it is possible for this method to evaluate the technology competitiveness easily and repeatedly, in terms of IT innovativeness by inter-organizations and inter-nations. For the case analysis, the Mongolian IT market with several Korean IT joint firms is introduced, and final data resulted from an early-adoptive phase case are analyzed.

A Novel Current Measurement Method for Two-Phase Half-bridge Inverter using Single Current Sensor (단일 전류 센서를 이용한 2상 하프브릿지 인버터의 상전류 측정 방법)

  • Cho, Young-Hoon;Mok, Hyung-Soo;Jang, Do-Hyun;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.193-195
    • /
    • 2007
  • This paper proposed a novel current measurement method for two-phase half-bridge inverter using single current sensor. The proposed method measures DC link input current and a phase current simultaneously and reconstructs each phase currents by simple calculation according to voltage vector. The commutation modes of two-phase half-bridge inverter is analized. The current sampling and reconstructing method is also presented. The proposed method is verified through simulation and experimental results on two-phase induction motor drive system.

  • PDF

Switching Method to Minimize the Current Ripple of 3-Phase Interleaved Bidirectional DC-DC Converter in Light Load Operation (3상 인터리브드 양방향 DC-DC 컨버터의 경부하 동작 시 전류 리플 최소화를 위한 스위칭 기법)

  • Jung, Jae-Hun;Nho, Eui-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.55-62
    • /
    • 2015
  • This paper deals with a switching method to minimize the current ripple component of 3-phase interleaved bidirectional DC-DC converter for charging and discharging of the battery. The characteristics of the output current ripple in 3-phase and 2-phase operation modes according to the variation of battery voltage is analyzed and a phase conversion method for minimizing the magnitude of the current ripple is proposed. The proposed method can extend the light load range because the switching frequency is lower than that of a 3-phase operating system. Simulation and experimental results show the usefulness of the proposed method.

Drive Characteristics of SRM According to Excitation Strategy (SRM의 여자방식에 따른 운전특성)

  • Kim, Tae-Hvoung;Ahn, Tin-Woo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.10
    • /
    • pp.455-460
    • /
    • 2005
  • A simple construction and low cost, fault tolerant power electronic drive has made the switched reluctance drive a strong contender for many applications. But, switched reluctance drive does exhibit higher levels of vibration and acoustic noise than that of most competing drives. The main source of vibration in the switched reluctance drive is generated by rapid change of radial magnetic force when phase current is extinguished during commutation action. In this paper,2 excitation method is proposed and compared to reduce vibration and acoustic noise of the switched reluctance drive. The excitation strategies considered this research are 1-phase, 2-phase and hybrid excitation method. 1-phase method is a conventional and 2-phase method is excited 2 phases simultaneously. The hybrid excitation has 2-phase excitation by long dwell angle as well as conventional 1-phase excitation. The vibration and acoustic noise are compared and tested. Suggested 2-phase and hybrid strategies reduce acoustic noise because the scheme reduces abrupt change of excitation level by distributed and balanced excitation.