• Title/Summary/Keyword: Phase current magnitude variation

Search Result 13, Processing Time 0.04 seconds

Current Ripple Reduction Method of 3-phase Interleaved Bidirectional DC-DC Converter with the Consideration of Input and Output Voltage Variation (입·출력 전압 변동을 고려한 3상 인터리브드 양방향 DC-DC컨버터의 전류리플 저감 기법)

  • Sun, Daun;Jung, Jae-Hun;Nho, Eui-Cheol;Joung, Gyu-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.427-433
    • /
    • 2016
  • This paper proposes a new method for the current ripple reduction of a three-phase interleaved bidirectional DC-DC converter. Usually, the three-phase interleaved bidirectional DC-DC converter is used for battery charging and discharging to reduce battery current ripple. In V2G application, a PWM AC-DC converter is used to connect the AC power grid and three-phase interleaved bidirectional DC-DC converter for battery charging and discharging. The magnitude of DC link voltage affects the battery current ripple magnitude. Therefore, the magnitude of the battery ripple current is analyzed with variations of battery and DC link voltages. The ripple current magnitude is found to be minimized by controlling the DC link voltage. Simulation and experimental results show the usefulness of the proposed method.

A Study on DC-Link Current Ripple of Multi-Phase/Multi-Stage Boost Converter (다상/다단 부스트 컨버터의 DC-Link 리플 전류 분석)

  • Seung-Min Kim;Dong-Hee Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.59-67
    • /
    • 2023
  • This paper explores the variation of DC-Link current ripple analysis in terms of duty cycle and phase angle of Multi-phase/Multi-stage boost converter. A 2-Stage/1-Stage boost converter DC-Link current is used to determine the difference between the 1st stage diode current and the 2nd stage inductor current. Each stage boost converter diode and inductor current is subordinate to the phase angle and duty cycle. The magnitude of the ripple current is variable according to phase angle and duty cycle. The analysis results are verified by variation of DC-Link current ripple using a 1kW typical 2-stage/1-stage boost converter.

Improvement of Current Controller Characteristics of Interior Permanent Magnet Synchronous Motor for Electric Vehicle (전기자동차용 매입형 영구자석 동기전동기의 전류제어기 특성 개선)

  • Park, Jung-Woo;Kim, Jong-Moo;Ku, Dae-Hyun;Kim, Heung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2526-2528
    • /
    • 1999
  • Parameters of equivalent circuit of IPMSM are varied according to current magnitude and current phase angle. Especially, Parameter variation of IPMSM for an electric vehicle(EV) is critical. Because current magnitude is very large. and current phase angle range also is wide. So, variation characteristics of $L_d$ and $L_q$ of the IPMSM are analyzed and verified through experiments. And then new parameter estimator of $L_d$ and $L_q$ that is constructed by neural network technique is suggested Using numerical method, the advanced characteristics of current controller of vector control algorithm is verified.

  • PDF

Phase Current Magnitude Variation Method to Reduce End-Effect Force of PM Linear Synchronous Motor

  • Kim, Min-Jae;Lim, Jae-Won;Yim, Woo-Gyong;Jung, Hyun-Kyo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.793-798
    • /
    • 2011
  • Numerous methods are available for reducing the end-effect force of linear machines. Majority of these methods focus on redesigning the poles or slots. However, these methods require additional manufacturing cost and decrease the power density. The current paper introduces another approach to reduce the end-effect force. The new approach is a method of tuning the input phase current magnitudes individually. According to the proposed method, reduction of the end-effect force could be achieved without redesigning the poles/slots or attaching auxiliary poles/slots. The proposed method is especially applicable when the target motor is very expensive or will be used for a special mission, such as hauling army vehicles equipped with three single-phase inverters. The validity of the suggested method was exemplified by the finite element method with three-phase permanent-magnet linear synchronous motor.

Switching Method to Minimize the Current Ripple of 3-Phase Interleaved Bidirectional DC-DC Converter in Light Load Operation (3상 인터리브드 양방향 DC-DC 컨버터의 경부하 동작 시 전류 리플 최소화를 위한 스위칭 기법)

  • Jung, Jae-Hun;Nho, Eui-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.55-62
    • /
    • 2015
  • This paper deals with a switching method to minimize the current ripple component of 3-phase interleaved bidirectional DC-DC converter for charging and discharging of the battery. The characteristics of the output current ripple in 3-phase and 2-phase operation modes according to the variation of battery voltage is analyzed and a phase conversion method for minimizing the magnitude of the current ripple is proposed. The proposed method can extend the light load range because the switching frequency is lower than that of a 3-phase operating system. Simulation and experimental results show the usefulness of the proposed method.

The comparison of harmonic detection methods on the Power line (상용(220V/60Hz)전원의 고조파 검출 방식의 비교)

  • Jung Dong-Youl;Hwang Hwan-Young;Park Chong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.883-886
    • /
    • 2004
  • The current harmonic detector consists of the load current detector and the notch filter. It obtains the harmonic current from the output of the load current detector using the Notch filter. The GIC in the notch filter is used instead of inductor to minimize the magnitude and phase characteristics variation caused by using twin-T notch filter and passive elements(inductor).

  • PDF

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.

Analysis of RPC Probe Signal for S/G Tube in Nuclear Power Plant Considering Defect Factor (결함인자를 고려한 원전 SG세관에서의 RPC 프로브의 신호 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.53-55
    • /
    • 2005
  • The signals of the eddy current testing(ECT) for the examination of the steam generator(SG) tubes in the nuclear power plant(NPP) determine the existence, size, and kind of defects using the variation of impedance signals when a testing coil, driven by alternating current, passes through the SG tube contains defects. The aim of this paper is building a database of the RPC probe signals on the basis of the sizes variation of defects and frequency variation of probe. In this paper 3-D numerical analysis of the ECT signals using the finite element method is performed. Through this study, it is shown variation of magnitude and phase of impedance according to variation of defect size and frequency. From the result of this paper, we can obtain the information which is useful in defect discrimination of SG tube in nuclear power plant.

  • PDF

DCM Analysis of Interleaved Boost Converter for Fuel Cell Applications (연료전지용 다상 부스트 컨버터 불연속 모드 특성 해석)

  • Kim, Dong-Hee;Choe, Gyu-Yeong;Kim, Jong-Soo;Lee, Byoung-Kuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.88-95
    • /
    • 2010
  • In this paper, the variation of phase current and input current ripple of interleaved boost converter at DCM for fuel cell applications are theoretically analyzed. Also, based on the detailed analysis, numerical formula of input current ripple expressed in rising and falling slope magnitude, D, and $D_A$ is proposed. In order to verify proposed formulas, simulation and experimental results are compared with theoretical data and validity of proposed theory is established.

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF