• 제목/요약/키워드: Phase contrast microscope

검색결과 105건 처리시간 0.033초

Improving Phase Contrast of Digital Holographic Microscope using Spatial Light Modulator

  • Le, Thanh Bang;Piao, Meilan;Jeong, Jong-Rae;Jeon, Seok-Hee;Kim, Nam
    • Journal of the Optical Society of Korea
    • /
    • 제19권1호
    • /
    • pp.22-28
    • /
    • 2015
  • We propose a new method for improving the phase contrast of a multiphase digital holographic microscope using a spatial light modulator (SLM). Using the SLM as the annulus, our method improves the light contrast of the object edge to achieve higher accuracy. We demonstrate a digital holographic microscopy technique that provides a 30% improvement in the phase contrast compared to conventional microscopy, which utilizes a mechanical annulus. The phase-contrast improvement allows the 3D reconstructed hologram to be determined more precisely.

형광 현미경을 이용한 비상용 고분자 블렌드 용액의 전단 균질화 연구 (Shear Induced Homogenization Study of an Immiscible Polymer Blend Solution Using Fluorescence Microscope)

  • 유재웅
    • 폴리머
    • /
    • 제27권5호
    • /
    • pp.413-420
    • /
    • 2003
  • 형광 현미경을 이용하여 4-클로로-7-니트로벤조퓨라잔이 표지된 폴리스티렌과 폴리부타디엔 블렌드 디옥틸프탈레이트 용액의 전단력하에서의 상평형 거동을 관찰하였다. 형광 현미경과 위상차 현미경을 동시에 사용하여 형광이미지가 실제 블렌드용액의 모폴로지와 같음을 알 수 있었다. 형광 현미경을 이용하여 각 도메인에서 형광의 세기를 측정함으로써 도메인상 (폴리스티렌 풍부상)과 연속 매트릭스상 (폴리부타디엔 풍부상)이 외부에서 가해준 전단력에 의하여 조성비가 변화하는 것을 관찰하였다. 이렇게 측정되어진 전단력의 변화에 따른 조성 차이의 변화로부터 상분리 곡선이 이동함을 알 수 있었다.

경 엑스선 위상차 현미경을 이용한 유방 조직의 방사광 영상 (Synchrotron Radiation Imaging of Breast Tissue Using a Phase-contrast Hard X-ray Microscope)

  • 정영주;봉진구;박성환
    • 한국의학물리학회지:의학물리
    • /
    • 제22권3호
    • /
    • pp.117-123
    • /
    • 2011
  • 방사광 영상은 내부가 보이지 않는 생물학적 검체의 구조를 관찰하는데 사용될 수 있으며, 조직의 고정이나 염색없이 비침습적으로 조직의 미세 구조를 관찰하는데 유용하다. 본 연구에서는 포항방사광가속기의 1B2 빔라인에서 개발한 경엑스선(hard X-ray) 현미경을 이용하여 11.1 KeV의 에너지에서 인간 유방 조직의 현미경적 영상을 얻고자 하였으며, 고해상도의 영상을 얻기 위해 동심원 회전판(zone plate)과 위상차 영상기법을 사용하였다. 실험 결과 경 엑스선 현미경을 이용하여 유방 섬유낭성변화와 유방암 조직의 방사광 미세 영상을 얻었으며, 이들 영상의 공간 해상도는 60 nm로 각각의 유방 조직의 미세 구조를 관찰하기에 충분하였다. 또한 방사광 미세 영상과 기존의 유방촬영 영상을 비교하였을 때, 방사광 미세 영상에서 각 조직의 특징적인 형태학적 변화가 더 뚜렷하게 나타나는 것을 관찰할 수 있었다. 결론적으로, 경엑스선 위상차 현미경을 이용한 방사광 영상은 유방 질환의 진단에 많은 도움을 줄 수 있을 것으로 생각되며, 임상적으로나 여러 연구 목적으로 유용하게 사용될 수 있을 것으로 기대된다.

쿼드러춰 방식에 의한 초음파현미경의 진폭과 위상영상 분석 (The Analysis of Amplitude and Phase Image for Acoustic Microscope Using Quadrature Technique)

  • 김현;전계석
    • 한국음향학회지
    • /
    • 제18권3호
    • /
    • pp.55-61
    • /
    • 1999
  • 본 연구에서는 쿼드러춰 방식의 초음파현미경을 구성하고 미세한 높이변화를 갖는 표면결함에 대한 진폭영상과 위상영상을 복원하여 상대적인 영상 강도의 변화와 영상의 질을 비교 분석하였다. 본 실험에서는 중심주파수가 3㎒인 focused 변환기를 사용하여 초음파현미경을 구성하고 알루미늄 재료를 선택하여 하나는 직경이 2㎜이고 깊이가 100㎛인 원형결함을 갖도록 하였고 다른 하나는 직경이 4㎜이고 깊이가 5㎜인 원형결함을 갖도록 시편을 제작하였으며 이들에 대한 진폭과 위상영상을 복원하였다. 결함 깊이가 100㎛인 원형결함이 존재하는 시편에 대한 라인 스캔(line scan) 결과 상대적인 영상강도의 진폭 변동율은 7%로 미약한 반면에 위상 변동율은 89%로 커다란 변화를 나타내므로 결함에 대해서 위상영상이 우수한 콘트라스트를 보였다. 이에 비하여 결함의 깊이가 5㎜인 시편에 대해서 진폭영상은 위상영상에 비하여 우수한 콘트라스트를 보이므로서 결함 깊이가 한 파장을 기준으로하여 위상영상과 진폭영상은 큰 차이를 나타내었다. 따라서 쿼드러춰 검출방식의 초음파현미경은 진폭만을 검출하는 포락선 검출기에 비해 한 파장보다 작은 높이변화를 갖는 결함의 탐상시 위상영상을 진폭영상의 상호보완적인 관계로 사용하므로서 결함의 미세 높이 변동을 효율적으로 평가 할 수 있다.

  • PDF

BAM(Brewster-Angle Microscope)으로 관측한 Langmuir막의 상전이에 관한 연구 (The Study on the Phase Transition of Langmuir Film by Brewster-Angle Microscope)

  • 조완제;송경호;박태곤;박근호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.323-326
    • /
    • 2000
  • In this study, we used Brewster-Angle Microscope(BAM) to study on the molecular orientation of monolayer on the water surface. The behaviors of molecules on three different subphase have been observed. Reproducible $\pi$-A isotherm have been obtained only on information about phase transition by molecular area. BAM facilitates the observation of morphology by optical anisotropy and thickness in monolayer and multilayers as BAM is shown to be sensitive to anisotropy of film. Every transition was found by BAM technique, either as a dramatic change in degree of contrast or as a sudden alteration of molecular action and $\pi$-A isotherm.

  • PDF

Competition between Phase Separation and Crystallization in a PCL/PEG Polymer Blend Captured by Synchronized SAXS, WAXS, and DSC

  • Chuang Wei-Tsung;Jeng U-Ser;Sheu Hwo-Shuenn;Hong Po-Da
    • Macromolecular Research
    • /
    • 제14권1호
    • /
    • pp.45-51
    • /
    • 2006
  • We conducted simultaneous, small-angle, X-ray scattering/differential scanning calorimetry (SAXS/DSC) and simultaneous, wide-angle, X-ray scattering (WAXS)/DSC measurements for a polymer blend of poly($\varepsilon$-caprolactone)/poly(ethylene glycol)(PCL/PEG). The time-dependent SAXS/DSC and WAXS/DSC results, measured while the system was quenched below the melting temperature of PCL from a melting state, revealed the competitive behavior between liquid-liquid phase separation and crystallization in the polymer blend. The time-dependent structural evolution extracted from the SAXS/WAXS/DSC results can be characterized by the following four stages in the PCL crystallization process: the induction (I), nucleation (II), growth (III), and late (IV) stages. The influence of the liquid-liquid phase separation on the crystallization of PCL was also observed by phase-contrast microscope and polarized microscope with 1/4$\lambda$ compensator.

Ultrasonic Image of the Side Drilled Holes in SS Reference Block as Combining Bases of Support for Spatial Frequency Response

  • 구길모;송철화;백원필;강희영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.322-326
    • /
    • 2008
  • In this paper, we have studied the images which have been reconstructed by using combination of images acquired by the variation of operating frequency. When inner images have been reconstructed, they have been superposed by the surface state effect. In this case, the images of the phase object can be enhanced by the contrast of inner images. There is a kind of specimen, one is a reference block having 1/4T, 1/2T, 3/4T side drilled holes as main run piping material of the steam generator in nuclear power plants. It has been shown that the two results of defect shapes have better than before in this processing and phase contrast grow about twice. And we have constructed the acoustic microscope by using a quadrature detector that enables to acquire the amplitude and phase of the reflected signal simultaneously. Further more we have studied the reconstruction method of the amplitude and phase images, the enhancement method of the defect images' contrast.

  • PDF

축 방향 공간주파수 대역의 확장을 통한 고체 내부영상 개선 (The Enhancement of Inner-solid Image by the Bandwidth Increment of Vertically Spatial Frequency)

  • 구길모;김상백;김현;전계석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.176-180
    • /
    • 2001
  • In this paper, we have studies the images have been reconstructed by using combination of images which has been acquired by the variation of operating frequency. When inner images has been reconstructed, inner image has been superposition by surface state effect. In this case, image enhancement the phase object and enhance the contrast of inner image. In the result of the specimen for the round defect with 2mm diameter, for the types of the depth are 1.5mm, 2mm, 2.5mm, and 3mm, it has been show that the shape of defect has better than before this processing and phase contrast grow large twice. And we have constructed the acoustic microscope by using quadrature detector that is able simultaneously to acquired the amplitude and phase of the reflected signal. Father more we have studied the reconstruction method of the amplitude and phase images and the enhancement method of the defect images' contrast.

  • PDF

Phase Imaging of Worn Surface of TiN Coating and Interpretation by Force Spectroscopy

  • Hyo Sok;Chizhik, S-A;I Luzinov
    • KSTLE International Journal
    • /
    • 제1권2호
    • /
    • pp.69-75
    • /
    • 2000
  • The paper compares topography, phase contrast and force spectroscopy in atomic force microscopy data for evaluating the microheterogeneity of surface layer. The worn surface of ion-plated TiN coating was measured using both a laboratory-built and a commercial AFM. The results of analysis revealed structural and micromechanical heterogeneity of the worn surfaces. We demonstrated that the phase image allows relatively qualitative estimation of elastic modulus of the sample surface. The tribolayer formed in the worn surface possessed much lower stiffness than the original coating. It is shown that the most stable phase imaging is provided with a stiff cantilever. In this case, phase contrast is well conditioned, first of all, by microheterogeneity of elastic properties of the investigated surfaces. In this study an attempt was also made to correlate the results of phase imaging with that of the farce spectroscopy. The joint analysis of information on the surface properties obtained by the phase imaging and quantitative data measured with the force spectroscopy methods allows a better understanding of the nature of the surface micromechanical heterogeneity.

  • PDF

상경계 PZT 세라믹스의 강유전 분역구조 및 정방정상과 능면체정상의 공간적 배열 (Ferroelectric Domain Structure and Array of Tetragonal and Rhombohedral Phase in PZT Ceramics at MPB Composition)

  • 천채일;김호기
    • 한국세라믹학회지
    • /
    • 제30권11호
    • /
    • pp.919-924
    • /
    • 1993
  • Domain structure and the spatial arrangement of tetragonal and rhombohedral phases in PZT ceramics at MPB composition were investigated with a transmission electron microscope. Fringe Contrast and doublet spot splitting were observed in the image mode and the selected area diffraction pattern, respectively. Besides, triplet spot splitting was also observed in the other part of the specimen. These observations indicate that both the single phase regions and the regions which are comosed of alternatively arranged tetragonal and rhombohedral domains coexist in a PZT ceramics at the MPB composition.

  • PDF