Characteristics of Metal Sensor using Variable Frequency (가변주파수형 금속감지 센서의 특성)
-
- The Journal of the Korea institute of electronic communication sciences
- /
- v.9 no.2
- /
- pp.161-166
- /
- 2014
This Electromagnetic metal piece detection sensor, having high sensitivity even under high humidity and dust density, using LVDT was investigated. Metal detection characteristics using phase detection method, for 3 frequencies covering ELF and LF band, were experimentally measured. It was found that the sensitivity for metal and animal food, in which metal piece was included, was exponentially increased as frequency increased. Reducing cutoff frequency of LPF after PD was found to be effective to proportionally increase sensitivity. Also the sensitivity of metal piece detection was enhanced by optimizing BPF bandwidth and SNR. Metal piece detection limit using available ferrous test samples was found to be 0.7mm diameter from the experiment using 50kHz, in ELF band, which was known to have better selectivity to animal food. is an example of ABSTRACT format.
This paper related with the I-CMA (Improved-CMA) algorithm that is possible to compensates of phase in CMA adatpve equalizer which is used for the elemination of intersymbol interference in the multipath fading and band limit characteristics of channel. The new cost function is proposed for the eliminate the amplitude and phase simulataneous by modifying the cost fuction for get the error signal in present CMA algorithm. It has a merit to the algorithm simplicities and eliminats the PLL device for phase compensation after equalization. For proving this, the recovered signal constellation that is the output of equalizer output signal and the residual isi and Maximum Distortion charateristic learning curve that are presents the convergence performance in the equalizer and the overall frequency transfer function of channel and equalizer were used. As a result of computer simulation, the I-CMA has more good compensation capability of amplitude and phas in the recovered constellation. But the convergence time is slow due to the simultaneously phase compensation.
Many short range weather radars with the low elevation search capability are needed for analysis and prediction of unusual weather changes or rainfall phenomena which occurs regionally. However, due to the characteristics of low elevation electromagnetic wave beam, it is highly probable that the received weather signals of these radars are seriously contaminated by the ground clutter. Therefore, the filter removing low Doppler frequency band is generally used to mitigate this problem. However, the phase noise in a radar system may limit the removal of the strong clutter and this may cause serious problems in estimating weather parameters because of the remaining clutter. Therefore, in this paper, the characteristics of phase noise in a radar system are investigated and the effects of the system phase noise are analyzed in the improvement of signal to clutter ratio for the strong clutter environment such as a short and low-elevated weather radar.
The progenitor of Type Ia supernovae (SNe Ia) is mainly believed to be a close binary system of acarbon-oxygen white dwarf (CO WD) and non-degenerate companion (single degenerate) or another WD (double degenerate). However, it is unclear which system is more prevalent. Here, we present a high cadence optical/Near-IR light curve of normal but slightly faint type Ia SN 2019ein from IMSNG project. We fit the early light curve (t <+8.3 days from the first detection) with various models to find the shock-heated cooling emission from SN ejecta-companion interaction. No significant shock-heated cooling emission is found, from which we constrain the progenitor star size as the following. The upper limit (Rupper,*) of the companion size in R-band is ~0.2R⊙ when forcing the first light time (tfl) to have one value and ~0.9R⊙ when using the mean value of tfl from the fitting in each band. Assuming the source of the I-band curve is almost powered from the radioactive decay, we obtained Rupper,*~1.2R⊙. The early B-V color curve is in agreement with the model color curve of the 2M⊙ main sequence companion. These results allow us to at least rule out large stars like red giants as a companion star of the binary progenitor system of this supernova. B-R and V-R color do not show any significant signs of a red bump, which shows a thin helium shell (MHe<0.1M⊙) for the sub-Mch WD (double detonation model). In addition, we estimated the distance to NGC 5353 as 37.098±0.028Mpc.
This paper presents the results of one of early sciences with Korean VLBI Network (KVN): a large fringe survey of compact radio sources at 43GHz. We established the catalog of correlated flux densities in three ranges of baseline projection lengths of 637 sources from a 43 GHz (Q-band) survey observed with the Korean VLBI Network. Of them, 623 sources have not been observed before at Q-band with VLBI. The goal of this work in the early science phase of the new VLBI array is twofold: to evaluate the performance of the new instrument that operates in a frequency range of 22--129 GHz and to build a list of objects that can be used as targets and as calibrators. We have observed the list of 799 target sources with declinations down to
A specific ammino auid in a mixture can be crystallized inside an ion exchange column when displacer concentration is high enough to concentrate the amino acid in a pure band beyond its solubility limit. Glutamic acid formpd a discrete crystal layer in a cation exchanger column by operating displacement development mode and using a high concentration of displacer NaOH. The glutamic acid crystal formed was eluded from the column with the effluent stream and collected in a fraction collector. When 1.0 M of NaOH was used as a displacer, more than 60% of the loaded glutamic acid was recovered as crystal. The continuous crystallization and dissolution of crystal occurred, resulting in apparent movement of the crystal along the column without clogging or pressure increase. NaOH was proved a better displacer than NaCl because hydroxide ions neutralized hydrogen ions released from the resin and thus reduced the number of hydrogen ion competing with sodium ion for re-adsorption. The displacement development process coupled with crystallization provided higher concentration and recovery of glutamic acrid than conventional chromatography.
This paper related with the DSE-MMA (Dithered Sign-Error MMA) that is the simplification of computational arithmetic number in blind equalization algorithm in order to compensates the intersymbol interference which occurs the passing the nonlinear communication channel in the presence of the band limit and phase distortion. The SE-MMA algorithm has a merit of H/W implementation for the possible to reduction of computational arithmetic number using the 1 bit quantizer in stead of multiplication in the updating the equalizer tap weight. But it degradates the overall blind equalization algorithm performance by the information loss at the quantization process compare to the MMA. The DSE-MMA which implements the dithered signed-error concepts by using the dither signal before qualtization are added to MMA, then the improved SNR performance which represents the roburstness of equalization algorithm are obtained. It has a concurrently compensation capability of the amplitude and phase distortion due to intersymbol interference like as the SE-MMA and MMA algorithm. The paper uses the equalizer output signal, residual isi, MD, MSE learning curve and SER curve for the performance index of blind equalization algorithm, and the computer simulation were performed in order to compare the SE-MMA and DSE-MMA applying the same performance index. As a result of simulation, the DSE-MMA can improving the roburstness and the value of every performance index after steady state than the SE-MMA, and confirmed that the DSE-MMA has slow convergence speed which meaning the reaching the seady state from initial state of adaptive equalization filter.
In this paper, the 3-mode variable gain high power amplifier for a transmitter of INMARSAT-B operating at L-band(1626.5-1646.5 MHz) was developed. This SSPA can amplify 42 dBm in high power mode, 38 dBm in medium power mode and 36 dBm in low power mode for INMARSAT-B. The allowable errol sets +1 dBm as the upper limit and -2 dBm as the lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier. The HP's MGA-64135 and Motorola's MRF-6401 were used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 for the high power amplifier. The SSPA was fabricated by the RP circuits, the temperature compensation circuits and 3-mode variable gain control circuits and 20 dB parallel coupled-line directional coupler in aluminum housing. In addition, the gain control method was proposed by digital attenuator for 3-mode amplifier. Then il has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. In this case, the SSPA detects the output power by 20 dB parallel coupled-line directional coupler and phase non-splitter amplifier. The realized SSPA has 41.6 dB, 37.6 dB and 33.2 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.3:1. The minimum value of the 1 dB compression point gets more than 12 dBm for 3-mode variable gain high power amplifier. A typical two tone intermodulation point has 36.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70