• Title/Summary/Keyword: Phase Velocity

Search Result 1,890, Processing Time 0.031 seconds

Kinematic analysis of skill between flexed and extended type of knee during Jigeo-Cha-Gi in Taekwon-Do (태권도 찍어차기의 무릎편 유형과 구부린 유형의 운동학적 비교분석)

  • Kim, Dong-Kyu;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.25-42
    • /
    • 2005
  • The study was to investigate kinematic difference between flexed and extended type of knee during Jigeo-Cha-Gi in Taekwon-Do. For this subjects participated were consisted of weights of fin (1), bantam (1) and welter class(1) of male 3 national representative level skilled in two type(flexed and extended type) of Jigeo-Cha-Gi. 3D cinematography analysis was performed for motion analysis and Kwon 3D ver. 3.1) was used for 3D coordinates & analysis variables calculation. In Temporal variable there was no significant difference statistically in all phases & total elapsed time between flexed and extended type, but flexed type was delayed more 0.016 sec than extended type. In displacement of COG there was significant difference in level of p<.05 showing longer mean 6.13 cm in case of flexed type than extended type in displacement of COG during all phase and too significant difference in level of p<.01 showing longer mean 4.4 cm in case of flexed type than extended type in displacement of COG in follow through phase. In velocity of COG there was significant difference in level of p<.001 showing higher mean 15.53cm/s in case of flexed type than extended type in velocity of COG(Y direction) during targeting phase and peak velocity(Y) was more fast 8.74 cm/s in extended type than flexed type. In velocity of leading leg in forward direction(Y) there was significant difference in level of p<.05 showing higher thigh mean value in case of flexed type than extended type but showing higher foot mean value in extended type at level of p<.001 than flexed type in velocity of COG(Y direction). In velocity of leading leg in vertical direction(Z) there was no significant difference in the second & third phase in case of vertical velocity level, but momentum transferred efficiently form proximal to distal endpoint. In front-back & right-left orientation angle of trunk there was possibility of more stable Jigeo-Cha-Gi in extended than flexed type by decreasing in right-left orientation angle of trunk. In relative angle of lower leg(hip, knee, ankle) there was significant difference in level of p<.001 showing longer mean 32.74 deg. in case of flexed type than extended type in hip joint during the second phase but maintained insufficient extended knee of mean 168 deg. in targeting phase.

A Study on the Drag Reduction by Shear-thinning Fluid in Turbulent Flow Fields (난류유동장에서 Shear - thinning 유체에 의한 마찰저항 감소에 관한 연구)

  • 차경옥;김재근;오율권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.126-135
    • /
    • 1997
  • Drag reduction in polymer solutions is the phenomenon where by extremely dilute solutions of high molecular weight polymers exhibit frictional resistance to flow much lower than the pure solvent. This effect, largely unexplained as yet, has attracted the attention of polymer scientists and fluid flow specialists. Although applications are beginning to appear, the principle interest to data has been in attempting to relate the effect to the fluid mechanics of turbulent flow. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, and pool and boiling flow. But the research on drag reduction in two phase flow is not intensively investigated. Therefore, experimental investigations have been carried out to analyze the drag reduction produced by polymer addition in the single phase and two phase flow system. The objectives of the proposed investigation are primarily in identifying and developing high performance polymer additives for fluid transportations with the benefits of turbulent drag. Also we want to is to evaluate the drag reduction in horizontal flow by measuring pressure drop and mean velocity. Experimental results show higher drag reduction using co - polymer(A611P) then using polyacrylamide (PAAM) and faster degradation using PAAM than using A611P under the same superficial velocity.

  • PDF

Fluidelastic instability of a tube array in two-phase cross-flow considering the effect of tube material

  • Liu, Huantong;Lai, Jiang;Sun, Lei;Li, Pengzhou;Gao, Lixia;Yu, Danping
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2026-2033
    • /
    • 2019
  • Fluidelastic instability of a tube array is a key factor of the security of a nuclear power plant. An unsteady model of the fluidelastic instability of a tube array subjected to two-phase flow was developed to analyze the fluidelastic instability of tube bundles in two-phase flow. Based on this model, a computational program was written to calculate the eigenvalue and the critical velocity of the fluidelastic instability. The unsteady model and the program were verified by comparing with the experimental results reported previously. The influences of void fraction and the tube's material properties on the critical velocity were investigated. Numerical results showed that, with increasing the void fraction of the two-phase flow, the tube array becomes more stable. The results indicate that the critical velocities of the tube array made of stainless are much higher than those of the other two tube arrays within void fraction ranging from 20% to 80%.

The finite difference analysis on temperature distribution by coordinate transformation during melting process of phase-change Material (상변화 물질의 용융과정에 있어서 좌표변환을 이용한 온도분포의 해석적 연구)

  • Kim, J.K.;Yim, J.S.
    • Solar Energy
    • /
    • v.5 no.2
    • /
    • pp.77-83
    • /
    • 1985
  • An analysis is performed to investigate the influence of the buoyancy force and the thickness variation of melting layer in the containment that is filled with phase-change Material surrounding a cylindrical heating tube during melting process. The phase-change material is assumed to be initially solid at its phase-change temperature and the remaining solid at any given time is still at the phase-change temperature and neglecting the effect of heat transfer occuring within the solid. At the start of melting process, the thickness of melting layer is assumed to be a stefan-problem and after the starting process, the change of temperature and velocity is calculated using a two dimensional finite difference method. The governing equations for velocity and temperature are solved by a finite difference method which used SIMPLE (Semi Implicit Method Pressure linked Equations) algorithm. Results are presented for a wide range of Granshof number and in accordance with the time increment and it is founded that two dimensional fluid flow occurred by natural convection decreases the velocity of melting process at the bottom of container. The larger the radius of heating tube, the higher heat transfer is occurred in the melting layer.

  • PDF

A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation (고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계)

  • Ahn, Yeh-Chan;Cha, Jae-Eun;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

Simultaneous measurement of size and velocity of micro-bubbles in an opaque tube using X-ray micro-imaging technique (X-ray 미세 영상기법을 이용한 불투명 튜브 내부 미세기포의 크기 및 속도 동시 측정)

  • Kim Seok;Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.45-46
    • /
    • 2003
  • The x-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to different refractive index. Micro-bubbles of $20\~120{\mu}m$ diameter moving upward in an opaque tube $(\phi=2.7mm)$ were tested. For two different working fluids of tap water and DI water, the measured velocity of micro-bubbles is roughly proportional to the square of bubble size.

  • PDF

Rayleigh waves in anisotropic magnetothermoelastic medium

  • Kumar, Rajneesh;Sharma, Nidhi;Lata, Parveen;Abo-Dahab, S.M.
    • Coupled systems mechanics
    • /
    • v.6 no.3
    • /
    • pp.317-333
    • /
    • 2017
  • The present paper is concerned with the investigation of Rayleigh waves in a homogeneous transversely isotropic magnetothermoelastic medium with two temperature, in the presence of Hall current and rotation. The formulation is applied to the thermoelasticity theories developed by Green-Naghdi theories of Type-II and Type-III. Secular equations are derived mathematically at the stress free and thermally insulated boundaries. The values of Determinant of secular equations, phase velocity and Attenuation coefficient with respect to wave number are computed numerically. Cobalt material has been chosen for transversely isotropic medium and magnesium material is chosen for isotropic solid. The effects of rotation, magnetic field and phase velocity on the resulting quantities and on particular case of isotropic solid are depicted graphically. Some special cases are also deduced from the present investigation.

A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile (자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구)

  • 임태우;박종운
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.

Fluid-elastic Instability in a Tube Array Subjected to Two-Phase Cross Flow (2 상 횡 유동장에 놓인 관군의 유체탄성불안정성)

  • Sim, Woo-Gun;Park, Mi-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.2
    • /
    • pp.124-132
    • /
    • 2009
  • Experiments have been performed to investigate fluid-elastic instability of tube bundles, subjected to twophase cross flow. Fluid-elastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to the cross flow. The test section consists of cantilevered flexible cylinder(s) and rigid cylinders of normal square array. From a practical design point of view, fluid-elastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping parameter. For dynamic instability of cylinder rows, added mass, damping and the threshold flow velocity are evaluated. The Fluid-elastic instability coefficient is calculated and then compared to existing results given for tube bundles in normal square array.

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.