• Title/Summary/Keyword: Phase Variable

Search Result 1,066, Processing Time 0.03 seconds

GENERAL FAMILIES OF CHAIN RATIO TYPE ESTIMATORS OF THE POPULATION MEAN WITH KNOWN COEFFICIENT OF VARIATION OF THE SECOND AUXILIARY VARIABLE IN TWO PHASE SAMPLING

  • Singh Housila P.;Singh Sarjinder;Kim, Jong-Min
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.4
    • /
    • pp.377-395
    • /
    • 2006
  • In this paper we have suggested a family of chain estimators of the population mean $\bar{Y}$ of a study variate y using two auxiliary variates in two phase (double) sampling assuming that the coefficient of variation of the second auxiliary variable is known. It is well known that chain estimators are traditionally formulated when the population mean $\bar{X}_1$ of one of the two auxiliary variables, say $x_1$, is not known but the population mean $\bar{X}_2$ of the other auxiliary variate $x_2$ is available and $x_1$ has higher degree of positive correlation with the study variate y than $x_2$ has with y, $x_2$ being closely related to $x_1$. Here the classes are constructed when the population mean $\bar{X}_1\;of\;X_1$ is not known and the coefficient of variation $C_{x2}\;of\;X_2$ is known instead of population mean $\bar{X}_2$. Asymptotic expressions for the bias and mean square error (MSE) of the suggested family have been obtained. An asymptotic optimum estimator (AOE) is also identified with its MSE formula. The optimum sample sizes of the preliminary and final samples have been derived under a linear cost function. An empirical study has been carried out to show the superiority of the constructed estimator over others.

A Model for VMS Message Reading Time Using Driving Simulator (Driving Simulator를 이용한 VMS 메시지 판독시간모형 개발)

  • Kim, Tae-Hyung;Kim, Sung-Min;Oh, Cheol;Kim, Jeong-Wan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.3
    • /
    • pp.24-32
    • /
    • 2007
  • Variable message sign (VMS), which is used for providing real-time information on traffic conditions and accident occurrences, is one of the important components of intelligent transportation systems. It is essential that the scheme of VMS message phase and duration should be designed with the consideration of drivers' message reading time that will be depended on various causal factors, such as the amount of VMS messages, drivers' travel speed, and geometric conditions. However, there have been not much efforts to explore the relationships between the drivers' message reading time and the above causal factors. Driving simulator experiments were conducted to obtain drivers' message reading time with respect to the amount of VMS messages, drivers' travel speed, and different geometric conditions. Regression modeling techniques were applied to develop an estimation model for drivers' message reading time. Probabilistic outcomes of the proposed model would be greatly utilized to design proper VMS message phase and duration.

  • PDF

Implementation and Verification of Linear Phase filter with Variable Cutoff Frequency for PCM/FM transmission (PCM/FM 전송을 위한 가변 컷오프 주파수 특성의 선형위상 필터 구현 및 검증)

  • Lee Sang-Rae;Ra Sung-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.713-724
    • /
    • 2006
  • The purpose of this study is to design, implement and verify the pre-modulation filter with the variable -3dB cutoff frequency and linear phase response for bandlimiting the allocation of radio frequency bandwidth for PCM/FM transmission. For the design of this required filter, the digital FIR filter, DAC system and tuneable 2nd order LPF have been constructed and simulated according to the attenuation characteristic requirement of the amplitude frequency response by each stage. From these results, we have implemented the filter and verified the analog conversion hardware part which is composed of DAC system and tuneable 2nd order LPF for the interpolation of the discrete sequences. Especially this paper proposes and carries out the verification processes using the tone generator and the calibration procedures for more precise frequency response of the filter.

A Study on the Development of 3[kW] Power Conversion System for Fuel Cell (3[kW]급 연료전지용 전력변환기 개발에 관한 연구)

  • Kim, Se-Min;Park, Sung-Jun;Song, Sung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.88-95
    • /
    • 2009
  • This paper is the research on the development of power conversion system for the fuel cell. In composing the DC/DC converters which have high boost voltage ratio, unlike the conventional method a new multi DC/DC converter system is proposed that the diode and the condenser and the reactor can be reduced by connecting the secondary side output of the transformer. In this system the rectifier part and the filter part of the secondary side in the power transformer that is connecting in series are composed into a single module, which is the strong advantage and the number of level can be easily increased. A new variable shift phase switching method is also suggested that it makes possible to reduce the output voltage ripples in the proposed system. All the factors mentioned above have been verified through simulations and experiments, and the proposed converter is considered very useful in the demanded load which requires a wide of the output.

The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축열전달에 관한 연구)

  • Son, Chang-Hyo;Jeong, Jin-Ho;O, Jong-Taek;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

Measurement of Phase Behavior for Dextran/DMSO/scCO2 System (Dextran/DMSO/초임계 CO2계의 상거동 측정)

  • Rho, Seon-Gyun;Kang, Dong-Yuk;Kang, Choon-Hyoung
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.225-229
    • /
    • 2017
  • Micron-sized dextran particles, which now attract wide attention as a promising drug delivery systems, can be prepared via the supercritical anti-solvent (SAS) process. In SAS process, dextran particles are obtained as a result of recrystallization of dissolved dextran in dimethyl sulfoxide (DMSO) on addition of supercritical $CO_2$ as an anti-solvent. In this work, with an intention to provide information on the feasible operating conditions of the process, the phase behavior of Dexran/DMSO/$CO_2$ is observed by measuring the cloud point in favor of a variable volume cell. From the experimental study, it is concluded that a feasible operating condition of the SAS process for preparation of dextran particles would be 300.15 K~330.15 K and 90 bar~130 bar, respectively, and solute concentration ranges from 5mg/ml to 20 mg/ml.

A Space Efficient Indexing Technique for DNA Sequences (공간 효율적인 DNA 시퀀스 인덱싱 방안)

  • Song, Hye-Ju;Park, Young-Ho;Loh, Woong-Kee
    • Journal of KIISE:Databases
    • /
    • v.36 no.6
    • /
    • pp.455-465
    • /
    • 2009
  • Suffix trees are widely used in similar sequence matching for DNA. They have several problems such as time consuming, large space usages of disks and memories and data skew, since DNA sequences are very large and do not fit in the main memory. Thus, in the paper, we present a space efficient indexing method called SENoM, allowing us to build trees without merging phases for the partitioned sub trees. The proposed method is constructed in two phases. In the first phase, we partition the suffixes of the input string based on a common variable-length prefix till the number of suffixes is smaller than a threshold. In the second phase, we construct a sub tree based on the disk using the suffix sets, and then write it to the disk. The proposed method, SENoM eliminates complex merging phases. We show experimentally that proposed method is effective as bellows. SENoM reduces the disk usage less than 35% and reduces the memory usage less than 20% compared with TRELLIS algorithm. SENoM is available to query efficiently using the prefix tree even when the length of query sequence is large.

The Effects of Simulated Mild Leg Length Discrepancy on Gait Parameters and Trunk Acceleration

  • Jung, Soo-jung;An, Duk-hyun;Shin, Sun-shil
    • Physical Therapy Korea
    • /
    • v.25 no.4
    • /
    • pp.9-18
    • /
    • 2018
  • Background: Leg length discrepancy (LLD) leads to many musculoskeletal disorders and affects daily activities such as walking. In the majority of the population, mild LLD is a common condition. Nevertheless, it is still controversy among researchers and clinicians on the effects of mild LLD during gait, and available studies have largely overlooked this issue. Objects: The purpose of the present study is to investigate the effects of mild LLD on the gait parameters and trunk acceleration. Methods: A total of 15 female and male participants with no evidence of LLD of >.5 ㎝ participated in the present study. All participants walked under the following two conditions: (1) The non-LLD condition, where the participants walked in shoes of the same heel height; (2) A mild LLD condition induced by wearing a 1.5 ㎝ higher heel on the right shoe. The GAITRite system and tri-axial accelerometer were used to measure gait parameters and trunk acceleration. To compare the variation of each variable, a paired t-test was performed. Results: Compared to the non-LLD condition, step time and swing phase were significantly increased in the mild LLD condition, while stance phase, single support phase, and double support phase significantly decreased in the short limb (p<.05). In the long limb of the mild LLD condition, single support phase significantly increased, while swing phase significantly decreased (p<.05). Furthermore, significant decrease in the gait velocity and cadence in the mild LLD condition were observed (p<.05). In the comparison between both limbs in the mild LLD condition, the step time and swing phase of the short limb significantly increased compared with the long limb, while step length, stance phase, and single support phase of the long limb significantly increased compared with the short limb (p<.05). Additionally, trunk acceleration of all directions (anterior-posterior, medial-lateral, vertical) significantly increased in the mild LLD condition (p<.05). Conclusion: The results of the present study demonstrate that mild LLD causes altered and asymmetrical gait patterns and affects the trunk, resulting in inefficient gait. Therefore, mild LLD should not be overlooked and requires adequate treatment.

An experimental study on the cooling performance and the phase shift between piston and displacer in the Stirling cryocooler

  • Park, S. J.;Y. J. Hong;Kim, H. B.;D. Y. Koh;B. K. Yu;Lee, K. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.111-117
    • /
    • 2003
  • In the design of the split type free displacer Stilting cryocooler the motion of the displacer is very important to decide the cooling capacity, which depends upon the working gas pressure, the swept volume in the compression space and the expansion space, operating frequency, the phase shift between piston and displacer, etc. In this study, Stirling cryocooler actuated by the electric farce of the dual linear motor is designed and manufactured. Cool down characteristics of the cold end with laser displacement sensor in the expander of the Stilting cryocooler is evaluated. The charging pressure was 15kg$_{f}$/$\textrm{cm}^2$ and operating frequency was 50Hz. Input power and the lowest temperature were about 32W and 67K, respectively. And, displacement of the piston is measured by LVDTs (Linear Variable Differential Transformers), displacement of thedisplacer is measured by laser optic method, and phase shift between piston and displacer is discussed. As the peak-to-peak pressure of the compressor was increased, peak-to-peak displacement of the displacer was increased. The peak-to-peak displacement of the displacer increases in the range of 0 - 64.5Hz(resonant frequency of the displacer), but decreases steeply when the operating frequency is bigger than the resonant frequency. Finally when the phase shift between displacements of the Piston and displacer is 45。, operating frequency is optimum and is decided by resonant frequency of the expander, mass and cross section area of the displacer and constant by friction and flow resistance.e.

Phase-matched Harmonic Generation and Variable Slope Exponential Weighting for Virtual Bass System (위상 일치와 가변 지수 감쇠 가중치 부여 방법이 적용된 가상 저음 시스템)

  • Moon, Hyeongi;Park, Young-cheol;Whang, Young-soo
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.889-898
    • /
    • 2016
  • Virtual Bass System (VBS) is widely used to extend the lower frequency limit of small loudspeakers, which generates harmonics of a fundamental frequency. The perceptual quality of the VBS is highly dependent on the harmonic weighting strategy. There have been several weighting methods, including exponential attenuation and timbre matching. However, it is essential to match phases between harmonics in the original signal and generate harmonics to precisely convey the weighting strategy. This paper shows the limitations of the previous harmonic weighting schemes and proposes a new harmonic weighting scheme. The proposed weighting scheme proposes phase matching between the original and generated harmonics and varies the slope of the attenuation weighting dynamically according to the missing fundamental frequency. Objective and subjective tests show that the proposed harmonic weighting scheme provides more natural and effective bass perception in a limited situation than the conventional schemes, which implies that the phase matching is essential for the high quality bass enhancement.