• Title/Summary/Keyword: Phase Feeding

Search Result 395, Processing Time 0.032 seconds

A Short-Term Longitudinal Investigation of Pre- and Postnatal Depressive Symptoms of Korean Women (산전후 우울 변화 - 성장혼합모형을 이용한 단기종단연구)

  • Shin, Na-Ry
    • Journal of the Korean Home Economics Association
    • /
    • v.49 no.9
    • /
    • pp.59-72
    • /
    • 2011
  • This study examined whether there are underlying latent classes of growth trajectories of maternal depression in the Korean population. Data from the first phase of the Panel Study of Korean Children (PSKC) of the Institute of Child Care and Education (KICCE) were used for this study. The final sample of participants included 1,471 mothers, who completed three interviews: at birth, at one month, and at four months. A two-class model consisting of depression (12.3%) and non-depression (87.7%) was considered the best-fitting solution using Mplus 3.13. The changes in postnatal depression in the Korean population within four weeks after childbirth, which is the period of "postpartum onset", seem to be important. Logistic regression analysis showed that duration of breast-feeding and planned pregnancy effects were significantly associated with trajectory class membership.

Development of the Continuous and Instantaneous Light liquid-Heavy liquid Centrifugal Separator using Density Difference (밀도 차를 이용한 경액과 중액의 연속 순간 원심분리기 개발)

  • 김영환;윤지섭;정재후;홍동희;박기용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.655-659
    • /
    • 2001
  • Resident time of the continuous and Instantaneous centrifugal separator using that separates the light and heavy liquids by use of density difference is the orptical factor that affects significantly the chemical metial extraction and the productivity in the chemical and mechanical process. In this paper, the overflow of the device is investigated under consideration of the relationships between inclination angle of liquid feeding screw and the centrifugal force. From the design of the length of a centrifugal separator, the radiuses of rotor and housing, theoretical formulation on the contact radius of separation weir is established through the experiments. From the experiments, it is identified that how much the capacity of inlet impeller and the emulsion phenomenon depend on the screw angle of inlet impeller. Also, we investigate the separation condition and the resident times that are functions of the phase ratio and density.

  • PDF

A review of the train position detection method for neutral section with energized condition (무절연구간을 위한 열차위치검지방식 검토)

  • Lee, Tae-Hoon;Lee, See-Bin;Hong, Hyun-Pyo;Lee, Hee-Soon;Park, Ki-Bum
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Optimal Construction of Rotary-Linear Induction Motor (회전-리니어 병용 유도전동기의 특성해석)

  • Onuki, Takashi;Jeon, Woo-Jin;Tanabiki, Masamoto;Yoo, Ji-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.130-132
    • /
    • 1997
  • In this paper, we propose a new type of tubular linear induction motor(TLIM) with two-dimensional motion. The proposed motor consists of four short primary LIMs arranged on a same circumference and a common secondary. By adopting independently energized ring-windings to the primary, we can expect the reduction of coil-end region and the freedom of alternating current supply. The secondary conductor is capable of producing anyone of rotary, linear, and helical motions by controlling the phase of supply currents in each primary winding. From the 3-D finite element analysis and the experiment, we derive the feeding conditions to increase the subsidiary rotary-force and an optimal arrangement of primary currents to reduce the number of slot.

  • PDF

Size, Scale and Rotation Invariant Proposed Feature vectors for Trademark Recognition

  • Faisal zafa, Muhammad;Mohamad, Dzulkifli
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1420-1423
    • /
    • 2002
  • The classification and recognition of two-dimensional trademark patterns independently of their position, orientation, size and scale by proposing two feature vectors has been discussed. The paper presents experimentation on two feature vectors showing size- invariance and scale-invariance respectively. Both feature vectors are equally invariant to rotation as well. The feature extraction is based on local as well as global statistics of the image. These feature vectors have appealing mathematical simplicity and are versatile. The results so far have shown the best performance of the developed system based on these unique sets of feature. The goal has been achieved by segmenting the image using connected-component (nearest neighbours) algorithm. Second part of this work considers the possibility of using back propagation neural networks (BPN) for the learning and matching tasks, by simply feeding the feature vectosr. The effectiveness of the proposed feature vectors is tested with various trademarks, not used in learning phase.

  • PDF

Improved Active Power Filter Performance Based on an Indirect Current Control Technique

  • Adel, Mohamed;Zaid, Sherif;Mahgoub, Osama
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.931-937
    • /
    • 2011
  • This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Primary Research on Theoretical Performance and Powder Supply Characteristics of Powder Rocket

  • Deng, Zhe;Hu, Chun-bo;Hu, Song-qi;Xu, Yi-hua
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.1-5
    • /
    • 2015
  • The powder propellant rocket which uses micron-sized particles as fuel is storable and costly. Functions like thrust control and multiple-ignition can be realized by changing powder mass flow rate. In this paper, we discuss the theoretical performance of bi-propellant and mono-propellant powder rocket. When used as the fluidization gas, helium can improve specific impulse dramatically. The stability of the powder feeding device is preliminarily quantified through metal/N2O powder rocket hot fire tests.

Help of Microcontroller on Voltage Control to Reduce Transformer Inrush Current

  • Fard, Ali Asghar Fathollahi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.1
    • /
    • pp.12-15
    • /
    • 2014
  • At the moment of transformer energization by the supply voltage, a high current called transient inrush current, which may rise to ten times the transformer full load current, could be drawn by the primary winding. This paper discusses a microcontroller circuit with the intention of controlling and limiting the inrush current for a transformer, by the method of ramping up the supply voltage feeding to the transformer primary. Simulations and the experimental results show a significant reduction of inrush current, when the ramping up voltage is applied to the three-phase transformer load. The inrush current could be almost eliminated if the correct switching step rate is chosen.