• Title/Summary/Keyword: Phase Doppler Particle Analyzer (PDPA)

Search Result 84, Processing Time 0.03 seconds

Pan-shaped Spray Characteristics of GDI High Pressure Slit Nozzle Injector (가솔린 직접분사식 고압 슬릿 노즐 분사기의 팬형 분무 특성 고찰)

  • Song, Bhum-Keun;Kim, Won-Tae;Kang, Shin-Jae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.70-76
    • /
    • 2005
  • A new stratified charge combustion system has been introduced and developed for GDI engines. Before this new GDI system, the stratified mixture was formed by a high pressure swirl injector. But, the special feature of new system is employed of a thin fan-shaped fuel spray formed by a slit type nozzle. Also, this system has been adopted a shell-shaped piston cavity. We made high pressure gasoline injection system and investigated the fan-shaped spray characteristics such as spray tip penetration, spray angle, SMD and velocities of droplets using PDPA(Phase Doppler Particle Analyzer) system and spray visualization system to obtain the concept of the new design and the fundamental data for the next generation GDI system. The experiment was performed at the injection pressures of 5 and 9MPa under the atmospheric condition.

Study on Spray Characteristics of Single-Hole GDI Injector according to Nozzle Hole Diameter - (2) Comparison of Spray Uniformity and Atomization Characteristics (노즐 홀 직경에 따른 단공 GDI 인젝터의 분무 특성 연구 - (2) 분무 균일도 및 미립화 특성 비교)

  • Park, Jeonghyun;Ro, Seungcheon;Chang, Mengzhao;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.25 no.4
    • /
    • pp.154-161
    • /
    • 2020
  • A single spray plume is the basic unit of the entire spray plume and is an important factor in understanding the spray characteristics. However, since the multi-hole GDI injector has a narrow spray angle, the superposition of the spray plumes occurs severely. Therefore, the spray uniformity and the spray atomization characteristics of a single spray plume were analyzed in this study using a single-hole GDI injector. Five single-hole GDI injectors with different nozzle hole diameters were used in the experiment. The uniformity of the spray was evaluated through the analysis of the spray pattern images. In addition, the atomization characteristics were compared using the diameter distribution of the spray droplets obtained using PDPA. As a result, the larger diameter of the nozzle hole, the less uniformity of the spray, and the injection pressure did not have a significant effect on the spray uniformity. It is judged that the surface roughness of the injector has a greater effect on spray uniformity than the diameter of the nozzle hole. Also, the size of the spray droplets increased sharply when the diameter of the nozzle hole was 230 ㎛.

Spray Characteristics of the Injector for the APU Gas Tubine Engine at Airplane Operating Conditions (항공기 작동조건에 따른 APU 가스터빈엔진 연료노즐의 분무특성)

  • Choi, Chea-Hong;Choi, Seong-Man;Lim, Byeong-Jun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.29-36
    • /
    • 2008
  • Spray characteristics for APU gas turbine engine are investigated. In the test, four flight conditions such as sea level idle, sea level max power, 20,000 feet idle, 20,000 feet max power are used as spray experimental conditions. Spray visualization was performed by using ND-YAG laser bean PDPA(Phase Doppler Particle Analyzer) was used for measuring the particle diameter and velocity from 20 mm to 100 mm from discharge orifice. From the test result, SMD is $90{\sim}95\;{\mu}m$ 맛 20,000 ft idle condition and SMD is $60{\sim}75\;{\mu}m$ at sea level idle condition. Also SMD is $55{\sim}65\;{\mu}m$ at 20,000 ft max power condition and SMD is $30{\sim}70\;{\mu}m$ at sea level max power condition. In the case of 20,000 ft idle condition, combustion instability could be occurred due to the higher drop diameter. Therefore it is necessary to decrease the droplet diameter in the high altitude condition.

Effect of Nozzle Hole Number on Fuel Spray and Emission Characteristics of High Pressure Diesel Injector (고압 디젤 인젝터 노즐 홀 수가 연료 분무 및 배기 특성에 미치는 영향)

  • Chon, Mun Soo
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.210-215
    • /
    • 2012
  • This paper This paper presents effect of nozzle hole number on spray characteristics and engine performance. Experiments were conducted to measure spray penetration and SMD distributions using a spray visualization system and PDPA (phase Doppler particle analyzer) system. In addition, engine performance and emission characteristics were measured using a single cylinder engine and emssion measurement systems. Results showed that 8-hole-injector exhibits improved spray performances. Furthermore, soot emission was decreased with 8-hole-injector, compared to that of 6-hole-injector.

Spray Characteristics of the Rotary Atomizer for the Slinger Combustor (슬링거 연소기의 회전형 분사장치의 분무특성 연구)

  • Choi, Hyun-Kyung;Lee, Dong-Hun;You, Gyung-Won;Choi, Seong-Man
    • Journal of ILASS-Korea
    • /
    • v.13 no.3
    • /
    • pp.149-155
    • /
    • 2008
  • An experimental study was performed to understand spray characteristics of the rotary atomizer for the slinger combustor. In this fuel injection system, fuel is injected and atomized in the combustor by centrifugal forces to engine shaft. The experimental apparatus consists of a high speed rotational spindle, rotary atomizer, pressure tank and acrylic case. The droplet size and velocity were measured by PDPA (phase Doppler particle analyzer), and spray was visualized by using high speed camera and Nd:Yag laser-based flash photography. From the test results, the droplet size (SMD) is largely affected by rotational speed, mass flow rate and the number of orifice. As the experimental results, we could understand the spray characteristics of the rotary atomizer for the slinger combustor and obtain the optimum shape of the rotary atomizer which is suitable for the small gas turbine engine.

  • PDF

Experimental Study on the Spray Characteristics for Sludge Removal Nozzle with High Pressure (슬러지 제거용 고압분사 노즐특성에 관한 실험적 연구)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.2
    • /
    • pp.155-160
    • /
    • 2004
  • Water jet trajectories and velocity deficits from a high pressurize nozzles were experimentally observed. In this article, several parameters affecting plugging and erosion onto the steam generator tube were quantitatively analyzed. Visualization, velocity distribution, and spray growth rate with different nozzle configurations have been mainly focused using a 2-D PDPA (Phase Doppler Particle Analyzer) system. The results indicated that trajectories along the centerline regardless of their momentum has its potential core region. However, the phenomena from the peripheral part need to be meticulosly considered. Accordingly, it is evident that quantitative velocity deficits at the outer region are outstanding due to the aerodynamical drag and entrainment.

액체로켓용 충돌형 인젝터의 질량분포 측정을 위한 PLLIF 기법에 대한 연구

  • 정기훈;고현석;이인수;윤영빈
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.1-1
    • /
    • 2002
  • PLLIF(Planar Laser Liquid Induced Fluorescence) 기법은 분무장을 교란시키지 않고 고해상도의 2차원 질량분포를 빠르게 측정할 수 있기 때문에 기존의 기계적인 분무 분포 측정방법의 한계를 극복하였을 뿐만 아니라 접근이 불가능하였던 인젝터 근방의 분무에 대한 중요한 정보를 제공하고 있다. 그러나 레이저 광을 받은 액적에 의한 산란광의 강도가 클 경우에는 인접한 액적들을 형광시킬 수 있고 액적의 형광신호가 액적들을 통과하면서 감쇠되는 이차산란에 의한 오차는 PLLIF 기법의 정량화에 가장 큰 난점으로 인식되고 있다. 특히 이러한 현상은 분무 분포의 밀도가 높고 액적의 크기가 클수록 강하게 나타나는데, 액체로켓에서 일반적으로 사용되고 있는 like-doublet 인젝터는 이러한 분무 특성을 갖는다. 따라서 Mechanical Patternator 및 PDPA(Phase Doppler Particle Analyzer)로부터 측정한 like-doublet 인젝터의 분무 질량 분포 결과와 비교하여 이차산란에 의한 오차를 파악하여 PLLIF 기법의 적용 가능성을 진단하였다.

  • PDF

Effect of Injector Energizing Duration on the Atomization Characteristics of Biodiesel Fuel (인젝터 통전기간이 바이오디젤 연료 미립화에 미치는 영향)

  • Suh, Hyun-Kyu;Park, Su-Han;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.108-114
    • /
    • 2007
  • This study investigates the influence of energizing duration on the fuel atomization characteristics of biodiesel injected through a high pressure common-rail injector. In order to analyze the effect of energizing duration on the fuel injection rate performance, the injection rate of biodiesel fuel is obtained from the pressure variation in the tube filled with fuel in injection measuring system. On the other hand, the atomization characteristics of biodiesel was measured and compared in terms of Sauter mean diameter(SMD), arithmetic mean diameter(AMD), droplet mean velocity, and detected droplets number by applying a phase Doppler particle analyzer(PDPA). It was revealed that the injection mass and maximum injection rate increase with increase of the energizing duration. Moreover, the increase of energizing duration improves the atomization performance of biodiesel fuel because it induces higher droplets momentum and velocity.

  • PDF

The Effects of Signal Attenuation on Spray Characterization Using Planar Imaging Technique (평면 이미지 기법을 이용한 분무 특성 해석 시 신호 감쇠의 영향)

  • Jeun Jayoung;Kim Dongjun;Koh Hyeonseok;Yoon Youngbin;Koo Ja Ye
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.295-298
    • /
    • 2002
  • In the analysis of the mass distribution and SMD (Sauter Mean Diameter), planar laser imaging technique Is a convenient and useful one when compared to the mechanical patternator or PDPA (Phase Doppler Particle Analyzer). But for the accurate usage of this laser technique, it is required to compensate the signal attenuation and to find the attenuation coefficients. In the present research, we considered effects of the spray distributions on the attenuation coefficient and improved the accuracy of planar laser imaging technique by the reduction of errors issuing from the signal attenuation.

  • PDF

Investigation of Turbulent Spray Disintegration Characteristics Depending on the Nozzle Configuration

  • Lee, Sam-Goo;Song, Kyu-Keun;Park, Byung-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.572-579
    • /
    • 2002
  • The experimental measurements were carried out to examine turbulent disintegration characteristics ejecting from a counter-flowing internal mixing pneumatic nozzle under variable conditions of swirl angles and air pressures. The air injection pressure was varied from 60 kPa to 180 kPa and four counter-flowing internal mixing nozzles with axi-symmetric tangential-drilled holes at swirl angle of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$to the central axis have been specially designed. The experimental results were quantitatively analyzed, focusing mainly on the comparison of turbulent atomization characteristics issuing from an internal mixing swirl nozzle. To illustrate the swirl phenomena, the distributions of mean velocities, turbulence intensities, volume flux, and SMD (Sauter Mean Diameter, or D$\sub$32/) were comparatively analyzed.