• 제목/요약/키워드: Phase Control Thyristor

검색결과 62건 처리시간 0.019초

위상정류제어기의 정밀출력제어 (Fine output voltage control of a phase-controlled converter)

  • 강유리;유동욱;백주원;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.240-242
    • /
    • 1994
  • Diode and thyristor-based bridge converter have been used for ac/dc conversion. Comparatively, diode bridges are simpler, more robust, less expensive and have a better power factor. However when voltage regulation is required, the thyristor-based phase-controlled converter have been used. But their use is limited by the low power factor and considerable harmonics in the input and output. An ac/dc power conversion scheme capable of fine output voltage control is investigated in this paper.

  • PDF

간단한 보조회로 추가에 의한 6-펄스 싸이리스터 컨버터의 다펄스화 (Pulse Multiplication of 6-Pulse Thyristor Converter with Simple Auxiliary Circuit)

  • 오준용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.294-298
    • /
    • 2000
  • A new pulse multiplication technique based on 6-pulse thyristor converters is proposed in this paper. With the proposed technique 12-pulse 18-pulse and 24-pulse operations have been obtained both on the input current and on the output voltage. A control strategy over the whole range of phase angle is provided along with sophisticated input current and output voltage analysis. Experimental results from a laboratory prototype verify the proposed theory.

  • PDF

간단한 보조회로 추가에 의한 6-펄스 싸이리스터 컨버터의 다펄스화 (Pulse Multiplication of 6-Pulse Thyristor Converter with Simple Auxiliary Circuit)

  • 정재혁;최세완;이인환;황용하
    • 전력전자학회논문지
    • /
    • 제5권6호
    • /
    • pp.568-574
    • /
    • 2000
  • 본 논문에서는 6-펄스 싸이리스터 컨버터에 간단한 보조회로를 추가하여 펄스 수를 증대시키는 방식을 제안한다. 제안한 방식으로 6-펄스 컨버터는 12-펄스, 18-펄스 및 24-펄스 동작을 하여 입력전류 뿐만 아니라 출략전압에서도 파형의 개선효과룹 가셔온다. 또한 입력전류 및 출력전압의 해석을 통하여 시스템의 전 위상각에 대한 보 조싸이라스터의 최적제어각을 계산하고 실험을 통하여 본 방식의 타딩성을 입증한다.

  • PDF

성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구 (A Study of Control Algorithm For Series Active Power Filter Using Performance Function)

  • 고수현;김진선;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

화력발전소 여자시스템 위상제어 정류기 설계에 관한 연구 (A Study of phase controlled rectifier design of excitation system for thermal power plant)

  • 이주현;류호선;임익헌;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1015-1017
    • /
    • 2002
  • This is the study on static excitation system of synchronous generator of large capacity in new model, which was developed by KEPRI using triple redundant digital method, associate three bridges of thyristor phase controlled rectifier. This paper will discuss the design conception and the application results of system which includes the power control devices(thyristors, GTO) and power excitation potential transformer. The multi-paralleling thyristor bridge converters of N+1 method have firing circuit. The initial product manufactured by proposed design in the study is in commercial operation, completing installation and commissioning in 400MW Thermal Power Plant. The performance test is done in practical technique.

  • PDF

고조파 전압원에 대한 직렬형 능동전력필터의 새로운 제어법 (A New Control Method of Series Active Power Filter with Harmonic Voltage Source)

  • 고수현;신재화;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1033-1036
    • /
    • 2002
  • This paper introduces a control method of series active power filter that compensate harmonic currents and eliminate a neutral line current in 3 phase 3 wire and 3 phase 4 wire power system with harmonic voltage source. These harmonic currents and neutral line current are caused by a nonlinear loads such as diode rectifiers and thyristor converters. Proposed methode extracts a voltage reference directly from performance function without phase transformation. Therefore, the control method is simpler than any other conventional methods. Experimental results for 3-phase 3-wire and 3-phase 4-wire series active power filter system were shown to verify the effectiveness of this control method.

  • PDF

고조파 전류와 무효전력보상을 위한 직렬형 능동전력필터 (A Series Active Power Filter For Harmonic Currents And Reactive Power Compensation)

  • 김진선;고수현;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권5호
    • /
    • pp.221-229
    • /
    • 2003
  • This paper suggests a control algorithm of 3-phase 3-wire series active power filter. This suggested algorithm can compensate source harmonics and reactive power in 3-phase 3-wire power distribution systems. These harmonics are generated by nonlinear loads such as diode rectifiers and thyristor converters. This control algorithm extracts a compensation voltage reference from performance function without phase transformation. Therefore, this control algorithm is simpler than any other conventional control algorithms. 3-phase 3-wire series active power filters which have a harmonic voltage source and a harmonic current source are manufactured and experiments are carried out to verify the effectiveness of suggested control algorithm.

Design and Application of a Nonlinear Coordinated Excitation and TCPS Controller in Power Systems

  • Hashmani Ashfaque Ahmed;Wang Youyi;Lie Tek Tjing
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권spc2호
    • /
    • pp.346-354
    • /
    • 2005
  • This paper presents a new approach to Thyristor Controlled Phase Shifter (TCPS) control. In this paper we have proposed a nonlinear coordinated generator excitation and TCPS controller to enhance the transient stability of a power system. The proposed controller is able to control three main parameters affecting a.c. power transmission: namely excitation voltage, phase angle and reactance in a coordinated manner. The TCPS is located at the midpoint of the transmission line. A nonlinear feedback control law is proposed to linearize and decouple the power system. The design of the proposed controller is based on the local measurements only. Simulation results have been shown to demonstrate the effectiveness of the proposed controller for the enhancement of transient stability of the power system under a large sudden fault.

고속전철 추진시스템의 전력변환장치 (Power Conversion Unit for Propulsion System of the High Speed Train)

  • 이병송;변윤섭;백광선
    • 한국철도학회논문집
    • /
    • 제2권2호
    • /
    • pp.39-45
    • /
    • 1999
  • This paper presents the current-fed inverter of a TGV-K traction system with thyristor switches using phase control and commutation techniques. The current-fed inverters have two modes of operation which consist of forced commutation and natural commutation. In forced commutation mode, at speed of less than 120km/h, commutation is forced by means of the commutation capacitors and the thyristors. Above 120km/h, the thyristors operate in natural commutation mode. according to the voltages between phases of the motors. In this paper. the power conversion theory of the TGV-K traction system and the control principle of the converter and current-fed inverter are discussed.

  • PDF

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.