• Title/Summary/Keyword: Phase Center

Search Result 4,806, Processing Time 0.032 seconds

A Study on Selective Laser Melting Process Considering Phase Transformation for Ti-6Al-4V (Ti-6Al-4V 합금에서 상 변화를 고려한 Selective Laser Melting 프로세스 연구)

  • Song, Seong-Il;Park, Joo-Heon;Jin, Byeong-Ju;Lee, Kyoung-Don
    • Journal of Korea Foundry Society
    • /
    • v.39 no.6
    • /
    • pp.110-115
    • /
    • 2019
  • Recently, various studies have been conducted on additive manufacturing technology developed using metal materials. In this study, a numerical analysis was introduced to analyze the effects of the thermal deformation and residual stress which arise during the SLM (selective laser melting) manufacturing process. A phase-transformation mechanism is implemented with the use of the Ti-6Al-4V material, in which a solid-state phase transformation (SSPT) can be induced during a numerical analysis. In this case, the phase of the Ti-6Al-4V material changes from a powder to a solid state and then to the Martensite phase in sequence during heating and cooling steps. The numerical analysis during the SLM process was verified by comparing the results of tensile tests with those from the numerical analysis based on the SSPT material properties.

Separation of Madecassoside and Madecassic Acid Isomers by High Performance Liquid Chromatography Using β -Cyclodextrin as Mobile Phase Additive

  • Kai, Guiqing;Pan, Jian;Yuan, Chuanxun;Yuan, Yuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.551-554
    • /
    • 2008
  • An improved HPLC method for the separation of madecassoside isomers (madecassoside and asiaticoside-B) has been developed. The isomers can be separated with high resolution from extracts of Centella asiatica by HPLC using $\beta$-cyclodextrin as a mobile phase added on a $C_{18}$ column. The result shows that the isomers can be separated with a mobile phase consisting of methanol:water (50:50, v/v) with 4 mmol/L $\beta$-CD. To elucidate the mechanism of the separation of madecassoside and asiaticoside-B, this paper studied the separation of their aglycon parts (madecassic acid and terminolic acid), another pair of isomers. The isomers can also be separated with high resolution with a mobile phase consisting of methanol:water (65:35, v/v) with 4 mmol/L $\beta$-CD and the pH of the mobile phase was adjusted to 4. The paper also studied the separation of the two isomers by HPLC using $\alpha$-CD and Glucosyl-$\beta$-CD as a mobile phase additive in order to elucidate the mechanism of the separation process.

Fabrication and Mechanical Properties of Nanoquasicrystalline Phase Reinforced Ti-based Bulk Metallic Glass Matrix Composites (나노 준결정상으로 강화된 Ti계 벌크 비정질기지 복합재의 제조 및 기계적 특성 고찰)

  • Park, Jin-Man;Lim, Ka-Ram;Kim, Tae-Eung;Sohn, Sung-Woo;Kim, Do-Hyang
    • Journal of Korea Foundry Society
    • /
    • v.28 no.6
    • /
    • pp.261-267
    • /
    • 2008
  • In-situ quasicrystalline icosahedral (I) phase reinforced Ti-based bulk metallic glass (BMG) matrix composites have been successfully fabricated by using two distinct thermal histories for BMG forming alloy. The BMG composite containing micron-scale Iphase has been introduced by controlling cooling rate during solidification, whereas nano-scale I-phase reinforced BMG composite has been produced by partial crystallization of BMG. For mechanical properties, micron-scale I-phase distributed BMG composite exhibited lower strength and plasticity compared to the monolithic BMG. On the other hand, nano-scale icosahedral phase embedded BMG composite showed enhanced strength and plasticity. These improved mechanical properties were attributed to the multiplication of shear bands and blocking of the shear band propagation in terms of isolation and homogeneous distribution of nanosize icosahdral phases in the glassy matrix, followed by stabilizing the mechanical and deformation instabilities.

Application of Ionic Liquids as Mobile Phase Modifier in HPLC

  • Polyakova Yulia;Koo Yoon-Mo;Row Kyung-Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Ionic liquids are receiving an upsurge of interest as 'green' solvents; primarily as replacements for conventional media in chemical processes. Although ionic liquids are rather 'young' modifier, their great potential in high-performance liquids chromatography (HPLC) has already been demonstrated. This review presents an overview of the applications of ionic liquids as mobile phase modifiers in HPLC.

A Comparative Study on the Power Spectrum of Three-Phase and Two-Phase RCD-PWM Scheme with Fixed Switching Frequency (고정 스위칭 주파수를 갖는 3상 및 2상 RCD-PWM의 파워 스펙트럼 비교)

  • Kim J.G.;Jung Y.G.;Lim Y.C.;Yang H.Y.;Wi S.O.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.308-312
    • /
    • 2003
  • The objective of this paper is to investigate the power spectrum of a three-phase and a two-phase RCD (Random Pulse Centered Displacement) PWM scheme. The two-phase or three-phase pulses of RCD-PWM scheme are mutually center-aligned as in SVM(Space Vector Modulation), but the common pulse center is displaced randomly from the middle of the period. To verify the validity of the proposed two-phase RCD-PWM scheme, the power spectra of the output voltage, the d.c link current in the inverter drives and the radiated acoustic noise are experimentally investigated. And, the performance of the proposed two-phase RCD-PWM scheme was compared and discussed with the conventional three-phase RCD-PWM scheme.

  • PDF

Effects of Contrast Phases on Automated Measurements of Muscle Quantity and Quality Using CT

  • Dong Wook Kim;Kyung Won Kim;Yousun Ko;Taeyong Park;Jeongjin Lee;Jung Bok Lee;Jiyeon Ha;Hyemin Ahn;Yu Sub Sung;Hong-Kyu Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1909-1917
    • /
    • 2021
  • Objective: Muscle quantity and quality can be measured with an automated system on CT. However, the effects of contrast phases on the muscle measurements have not been established, which we aimed to investigate in this study. Materials and Methods: Muscle quantity was measured according to the skeletal muscle area (SMA) measured by a convolutional neural network-based automated system at the L3 level in 89 subjects undergoing multiphasic abdominal CT comprising unenhanced phase, arterial phase, portal venous phase (PVP), or delayed phase imaging. Muscle quality was analyzed using the mean muscle density and the muscle quality map, which comprises normal and low-attenuation muscle areas (NAMA and LAMA, respectively) based on the muscle attenuation threshold. The SMA, mean muscle density, NAMA, and LAMA were compared between PVP and other phases using paired t tests. Bland-Altman analysis was used to evaluate the inter-phase variability between PVP and other phases. Based on the cutoffs for low muscle quantity and quality, the counts of individuals who scored lower than the cutoff values were compared between PVP and other phases. Results: All indices showed significant differences between PVP and other phases (p < 0.001 for all). The SMA, mean muscle density, and NAMA increased during the later phases, whereas LAMA decreased during the later phases. Bland-Altman analysis showed that the mean differences between PVP and other phases ranged -2.1 to 0.3 cm2 for SMA, -12.0 to 2.6 cm2 for NAMA, and -2.2 to 9.9 cm2 for LAMA.The number of patients who were categorized as low muscle quantity did not significant differ between PVP and other phases (p ≥ 0.5), whereas the number of patients with low muscle quality significantly differed (p ≤ 0.002). Conclusion: SMA was less affected by the contrast phases. However, the muscle quality measurements changed with the contrast phases to greater extents and would require a standardization of the contrast phase for reliable measurement.

Effect of Phase Stability on the Microstructure Development of α-SiAlON Ceramics

  • Kim, Joosun;Lee, Hae-Weon;Chen, I-Wei
    • Journal of Powder Materials
    • /
    • v.10 no.2
    • /
    • pp.118-122
    • /
    • 2003
  • Alpha-SiAlON ceramics having various compositions and modifying cations were investigated with respect to their phase stability, transformation kinetics. and resulting microstructures. Each composition was heat treated at 150$0^{\circ}C$ for 1h and measured the $\alpha$-SiAlON transformation. The phase-boundary composition in the single-phase $\alpha$-SiAlON region showed sluggish transformation from $\alpha$-$Si_3N_4$ to $\alpha$-SiAlON compared to the phase-center composition in the diagram. Using the different rare earth modifying cations, dependence of transformation kinetics on the phase stability in a fixed composition was also explained. By changing size of the stable u-phase region with exchanging cations, systematic change in transformation was observed. Transformation rate of $\alpha$-SiAlON at low temperature has an important role on controlling the final microstructure. Less transformation gives more chances to develop elongated grain in the microstructure.

The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery (진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교 평가)

  • Oh, Seung-Tae;Yoo, Mu-Sang;Bong, Suk-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-107
    • /
    • 2015
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external KeyPhasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

Comparison of Calibration Methods of Phase Center Variations for Precise GPS Monument Positioning (정확한 GPS 기준국 좌표산출을 위한 위상중심 변동량 계산방법 비교)

  • Won Ji-Hye;Park Kwan-Dong;Ha Ji-Hyun;Kim Sang-Ho
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.9-14
    • /
    • 2006
  • A determinated position with GPS (Global Positioning System) data processing is the position of the phase center of a GPS antenna. The phase center of a GPS antenna is. not a stable point and depends on the azimuth and elevation angles of GPS satellites. It is known that the phase center variations (PCV) of a GPS antenna are greater in the vertical than the horizontal directions. The PCV calibration models for a GPS. antenna has two approaches: relative and absolute. In this study. we compared the two calibration models using the six operational permanent GPS stations in South Korea and analysed the PCV of each station. In addition, we. tested two different kinds of GPS antennas and compared the results. The accuracy and precision of the relative calibration was worse than the absolute calibration.

  • PDF

Organic thin-film transistors and circuits manufactured by sub-femtoliter inkjets

  • Someya, Takao;Sekitani, Tsuyoshi;Noguchi, Yoshiaki;Yokota, Tomoyuki;Klauk, Hagen;Zschieschang, Ute
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1229-1232
    • /
    • 2008
  • We have successfully manufactured high-quality top-contact organic thin-film transistors using inkjet technologies with sub-femtoliter droplet volume. Silver fine lines were directly patterned by inkjet on pentacene channel layers. The minimum width of silver lines was $1{\mu}m$ with without the need for pre-patterning or surface pretreatments. The mobility was $0.3\;cm^2/Vs$.

  • PDF