• Title/Summary/Keyword: Phase Calibration

Search Result 501, Processing Time 0.027 seconds

Study on the melting characteristics of the Fe-C eutectic temperature fixed-point (Fe-C 공정 온도 고정점의 용융 특성에 대한 연구)

  • Kim, Yong-Gyoo;Yang, In-Seok;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.257-262
    • /
    • 2006
  • A Fe-C eutectic cell for thermocouple calibration was manufactured and tested to investigate its phase transition characteristics in the thermocouple thermometry. It was observed that the freezing plateaus were strongly affected by the freeze-inducing temperature $T_{f}$. In case of the melting process, the melting plateau was influenced by the previous thermal history. As $T_{f}$. in the previous freezing was lower, the melting plateau became lower with a temperature dependence as small as $-0.0015^{\circ}C/^{\circ}C$. Therefore, it was found that the freeze-inducing temperature should be fixed to obtain a reproducible phase transition temperature in the melting. After fixing $T_{f}$, the melting process was examined and it was found that long and flat melting plateau was obtained within a reproducibility of about ${\pm}0.01^{\circ}C$. Based on the observed results, it was recommended that Fe-C eutectic temperature be best realized for the melting process with a melt-inducing temperature of $+3^{\circ}C$ above the expected liquidus temperature after freezing at $-5^{\circ}C$ below the solidus temperature.

Availability Evaluation For Generation Orthoimage Using Photogrammetric UAV System (사진측량용 UAV 시스템을 이용한 정사영상 제작 및 활용성 평가)

  • Shin, Dongyoon;Han, Jihye;Jin, Yujin;Park, Jaeyoung;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.3
    • /
    • pp.275-285
    • /
    • 2016
  • This study analyzes the accuracy of ortho imagery based on whether camera calibration performed or not, using an unmanned aerial vehicle which equipped smart camera. Photgrammetric UAV system application was developed and smart camera performed image triangulation, and then created image as ortho imagery. Image triangulation was performed depending on whether interior orientation (IO) parameters were considered or not, which determined at the camera calibration phase. As a result of the camera calibration, RMS error appeared 0.57 pixel, which is more accurate compared to the result of the previous study using non-metric camera. When IO parameters were considered in static experiment, the triangulation resulted in 2 pixel or less (RMSE), which is at least 200 % higher than when IO parameters were not considered. After generate ortho imagery, the accuracy is 89% higher when camera calibration are considered than when they are not considered. Therefore, smart camera has high potential to use as a payload for UAV system and is expected to be equipped on the current UAV system to function directly or indirectly.

Subarray Channel Calibration and Performance Analysis for Digital Beam-Forming (디지털 빔 형성을 위한 부배열 채널 보정 및 성능 분석)

  • Jang, Sung-Hoon;Ahn, Chang-Soo;Kim, Dong-Hwan;Kim, Seon-Ju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.235-244
    • /
    • 2014
  • This paper describes the subarray channel configuration and calibration method for airborne AESA radar antenna. AESA radar demonstrator was designed and implemented for the digital beam-forming performance test of the 12 channel subarray structure. Magnitude and phase difference can be exist between the manufactured subarray channel. In this paper, calibration method for the subarray difference error was suggested. We measured digital monopulse slope in the subarray channel and verified the channel calibration effect. To verify the subarray channel operation, digital monopulse channel was compared with analog monopulse channel performance. AESA radar demonstrator was tested in the ground far field test range. Emulated single target was generated to test the detection and tracking performance of the demonstrator with the same waveform and search pattern. We verified that the detection and tracking performance of the 12 subarray digital monopulse channel was similar with the conventional analog monopulse channel. Also, ABF(Adaptive Beam-Forming) function for the sidelobe jammer was tested and effective operation was verified.

Analysis of Methamphetamine and Amphetamine in Oral Fluid of Eleven Drug Abusers (마약남용자 11명의 타액 중 메스암페타민의 분석)

  • Kim, Eun-Mi;Lee, Ju-Seon;Choi, Hye-Young;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.52 no.6
    • /
    • pp.419-425
    • /
    • 2008
  • A qualitative and quantitative analytical method was developed for detection of methamphetamine (MA) and its main metabolite amphetamine (AM) in oral fluid. Oral fluids of eleven drug abusers were provided by Police, specimens were collected by stimulation with a cotton swab treated with 20 mg of citric acid ($Salivette^{(R)}$; Sarstedt, USA). As the preliminary test, oral fluid samples were screened for amphetamines by Fluorescence Polarization Immunoassay (TDxFLx, Abbott Co.). Extraction for MA was performed using solid-phase extraction (SPE) by $RapidTrace^{TM}$ (Zymark, USA) with mixed mode cation exchange cartridge, CLEAN $SCREEN^{(R)}$ (130 mg/3 ml, UCT) after dilution with phosphate buffer. Samples were evaporated and derivatized by pentafluoropropionic acid anhydride (PFPA). Quantitation of MA and AM was performed by gas chromatography-mass spectrometry (GC-MS) using selective ion monitoring (SIM), the quantitation ions were m/z 204 (MA), 208 (MA-$D_5$), 190 (AM) and 194 (AM-$D_5$). The selectivity, linearity of calibration, limit of detection (LOD) and quantification (LOQ) within- and between day precision, accuracy and recoveries were examined as parts of the method validation. All oral fluid samples gave positive results to immunoassay for MA (cut-off level, 50 ng/ml as d-amphetamine). Concentrations of MA and AM by GC-MS in eleven samples were ranged 104.2${\sim}$4603.3 ng/ml and 32.4${\sim}$268.6 ng/ml, respectively. Extracted calibration curves of MA and AM were linear over the two concentration range of 1${\sim}$100 and 50${\sim}$1000 ng/ml with correlation coefficient of above 0.999. LOQ of MA and AM was 1 and 3 ng/ml, respectively. The intraand inter-day run precisions (CV) for MA and AM were less than 10%, and the accuracies (bias) for MA and AM were also less than 10% at the two different concentrations 5 and 100 ng/ml at low calibration range, 50 and 1000 ng/ml at high calibration range. The absolute recoveries of MA and AM at low and high calibration ranges were more than 82% and 75%, respectively. In this study the qualitative and quantitative analytical method of MA in oral fluid was established. Oral fluid testing may detect drug use in past hours because of its shorter detection window than urine, and be useful in post-accident situations. So oral fluids will be most useful for testing drug abuse in the driving under the influence of drug (DUID) as the alternative specimens of urine.

Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing (비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션)

  • Lee, Tae-Hun;Cho, Chan-Hee;Lee, Hee-Jong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

Analysis on the Measurement Results of the Focus Motor Position in MSC (Multi-Spectral Camera) on KOMPSAT - II

  • Heo, H.P.;Kong, J.P.;Kim, Y.S.;Park, J.E.;Chang, Y.J.;Lee, S.H.
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.372-375
    • /
    • 2006
  • The MSC is a high resolution multi-spectral camera system which is mounted on the KOMPSAT-II satellite. The electro-optic camera system has a refocusing mechanism which can be used in-orbit by ground commands. By adjusting locations of some elements in optics, the system can be focused precisely. The focus mechanism in MSC is implemented with stepper motor and potentiometer. By reading the value of the potentiometer, rough position of the motor can be understood. The exact location of the motor can not be acquired because the information from the potentiometer can not be so accurate. However, before and after certain events of the satellite, like a satellite launch, the direction of the movement or order of the magnitude of the movement can be understood. In this paper, the trend analysis of the focus motor position during the ground test phase is introduced. This result can be used as basic information for the focus calibration after launch. By studying the long term trend, deviation from the best focal point can be understood. The positions of the focus motors after launch are also compared.

  • PDF

Ultrasonic Images Enhancement of the SS Reference Specimen and the Reference Calibration Block for NPPs by the Combining Bases of Support for Spatial Frequency (공간주파수대역에서 기저대역 확장을 통한 원전 대비시험편과 대비 보정 시험편의 초음파 영상 개선)

  • Park, Chi-Seung;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.13 no.10
    • /
    • pp.651-657
    • /
    • 2003
  • Ultrasonic microscope has been used to detect the defects on surface or inner solid. Conventionally, it has used at a single operating frequency. The resolution and quality of the measured images are determined by a characteristic of the transducer of the ultrasonic microscope. The conventional ultrasonic microscope has been used envelope detector to detect the amplitude of reflected signal, but the changes in amplitude is not sensitive enough for specimen with microstructure that in phase. In this paper, we have studied multi-frequency depth resolution enhancement with ultrasonic reflection microscope for the reflectors of a stainless steel reference specimen and a reference calibration block to be used as the material in nuclear power plants for ISI, PSI. Increased depth resolution can be obtained by taking two, three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion and high quality signal distribution for the image to the changing rate of depth for the reflectors of the two kinds of specimens.

The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer (Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사)

  • Cho, Seung-Il;Kim, Sung-Boo;Lee, Jong-Kyu;Lee, Yong-Bong;Lee, Doo-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.

Effect of Sensitivity Variation for Mounting Methods of Accelerometer in Crash Test (충돌시험시 가속도 센서의 접착방법이 감도 변화에 미치는 영향)

  • Jang, Won-Ho;Kim, Ki-Oh;Beom, Hyen-Kyun;Kwon, Sung-Eun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.115-120
    • /
    • 2008
  • There are many typesof accelerometer sensor. There was mainly used high-g accelerometer to obtain data for vehicle in crash test. Accelerometer was mounted on test vehicle with mounting blocks. Test result can be influenced by condition of mounting i.e. bonding material and type of block. These influences can be evaluated to variation of sensitivity in calibration test. In this paper, Calibration test were carried out for 3 types of bonding material i.e. stud, beewax and double side tape. Other factor was taken into consideration by 3-types for mounting block. All test was conducted by sinusoidal signal vibrator up to 4500Hz. In order to investigate influence for sensitivity from different input voltage in the calibrator, the same test was repeated. Test results were compared with standard accelerometer data. Relative sensitivities and phases were showed small difference in sensitivity for bonding materials with one block, but significant one for another block and different input voltage below 1000Hz.

A New Calibration Method for the Characterization of Microwave Devices (마이크로파 소자 특성화를 위한 새로운 보정 방법)

  • 신헌철;유영길;정의붕;이종악
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.3
    • /
    • pp.10-16
    • /
    • 1991
  • The error networks due to the measuring systems and the test fixture must be previously calibrated in order to characterize the microwave devices. In this paper, it is presented a new method to characterize the error networks in which only two different microstrip lines are used for the calibration. Once each length of two calibrat- ing microstrip lines is accurately defined, the calibrated data can be easily obtained without acknowledgement for the propagation constant. The end effect is not considered when fabricated the microstrip lines used to calibration. The ATF13736 GaAs MESFET is characterized by means of the calibrating procedure with this method. The range of measuring frequency is 2 to 18 GHz, and the bias voltage and current are $V_{DS}$ =2.5V, $I_{DS}$ =20mA, respectively. Compared the calibrated data with data sheet, it is showed that the magnitude is nearly agreed with each other and the phase is deviated by 0.1 to 12 degrees in lower frequencies.

  • PDF