• Title/Summary/Keyword: Phantom variable

Search Result 39, Processing Time 0.025 seconds

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF

Quantitative localization of impacted mesiodens using panoramic and periapical radiographs

  • Choi, Hang-Moon;Han, Jin-Woo;Park, In-Woo;Baik, Jee-Seon;Seo, Hyun-Woo;Lee, Joo-Hyun;Park, Ho-Won
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Purpose : The purpose of this study was to evaluate a new technique for localizing impacted mesiodens using its horizontal magnification ratio on panoramic radiographs. Materials and Methods : Location-magnification equation of a panoramic equipment was obtained from horizontal magnification ratio of a metal ball which was located variable positions from the center of image layer at interval of 2 mm. Panoramic radiographs were obtained from a skull phantom with a metal ball which was a substitute for impacted mesiodens and was embedded 10mm(Group 1), 15mm(Group 2), and 20mm(Group 3) posterior to the central incisor. Each group obtained 7 panoramic radiographs at variable positions and one periapical radiograph. Three methods were used to estimate the actual width of the incisors and the balls which were used to calculate the magnification ratio. The methods included using the actual incisor width and the calculated ball width (Method 1), using the actual incisor width and the ball widths measured on periapical radiograph (Method 2), and using the incisor and the ball widths measured on periapical radiograph (Method 3). The location of the metal ball was calculated by using the location-magnification equation. Results : The smallest difference between the calculated and the actual distance was $0.1{\pm}0.7 \;mm$ in Group 1/ Method 3. The largest difference was $-4.2{\pm}1.6 \;mm$ in Group 3/Method 2. In all groups, method 3 was the most accurate. Conclusion : Quantitative localization of impacted mesiodens is possible by using panoramic radiograph.

A low noise, wideband signal receiver for photoacoustic microscopy (광음향 현미경 영상을 위한 저잡음 광대역 수신 시스템)

  • Han, Wonkook;Moon, Ju-Young;Park, Sunghun;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.507-517
    • /
    • 2022
  • The PhotoAcoustic Microscopy (PAM) has been proved to be a useful tool for biological and medical applications due to its high spatial and contrast resolution. PAM is based on transmission of laser pulses and reception of PA signals. Since the strength of PA signals is generally low, not only are high-performance optical and acoustic modules required, but high-performance electronics for imaging are also particularly needed for high-quality PAM imaging. Most PAM systems are implemented with a combination of several pieces of equipment commercially available to receive, amplify, enhance, and digitize PA signals. To this end, PAM systems are inevitably bulky and not optimal because general purpose equipment is used. This paper reports a PA signal receiving system recently developed to attain the capability of improved Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of PAM images; the main module of this system is a low noise, wideband signal receiver that consists of two low-noise amplifiers, two variable gain amplifiers, analog filters, an Analog to Digital Converter (ADC), and control logic. From phantom imaging experiments, it was found that the developed system can improve SNR by 6.7 dB and CNR by 3 dB, compared to a combination of several pieces of commercially available equipment.

Variables that Affect the Satisfaction of Brazilian Women with External Breast Prostheses after Mastectomy

  • Borghesan, Deise Helena Pelloso;Gravena, Angela Andreia Franca;Lopes, Tiara Cristina Romeiro;Brischiliari, Sheila Cristina Rocha;Demitto, Marcela de Oliveira;Agnolo, Catia Millene Dell;Carvalho, Maria Dalva de Barros;Pelloso, Sandra Marisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9631-9634
    • /
    • 2014
  • Background: : In 2012, the breast cancer estimate worldwide stood at 1.67 million new cases, these accounting for 25% of all types of cancer diagnosed in women. For 2014, 57,120 new cases are expected, with a risk estimated at 56.1 cases for every 100,000 women. The objective of this study was to analyze the satisfaction regarding the use of external breast prostheses by women undergoing mastectomy. Materials and Methods: This cross-sectional study was conducted with 76 women who used an external breast prosthesis (EBP), registered in the services of the Cuiaba Center for Comprehensive Rehabilitation, Mato Grosso, Brazil, from 2009 to 2012. Data were collected from the records of women who had requested the opening of a process of external breast prosthesis concession. Results: Satisfaction with the EBP was identified in 56.6% of the women. Those satisfied with the EBP reported that its weight was not annoying (p<0.01). Although the women felt body sensations of stitches, pains, pulling, dormancy and phantom limb, they are satisfied with the EBP. The variable related to the displacement of the breast prosthesis during activity of everyday life has demonstrated that even though the women have reported the possibility of displacements, they are satisfied with the EBP. The satisfaction with the use of external breast prosthesis did not affect the sexuality of the women with mastectomy. Conclusions: Learning the specificities of the EBP, taking into consideration the satisfaction of its use, allows the rehabilitation team, by listening to their clientele more attentively, following up this woman throughout her life journey, supporting and guiding the best way of use, with an eye to her personal, emotional and social life, as well as to her self-esteem.

Mediating Effects of Relief from Fatigue through Sleep and Perceived Subjective Health in the Relationship between Perceived Stress and Subjective Happiness in Middle School Who Attempted Suicide (자살시도 중학생의 스트레스와 주관적 행복감 (주관적 건강인지와 잠으로 피로회복정도의 평행다중매개모델))

  • Wi, Ok-Youn;Lee, Ji-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.229-238
    • /
    • 2018
  • The purpose of this study is to examine the difference in the mediating effects of relief from fatigue through sleep and perceived subjective health in the relationship between perceived stress and subjective happiness in middle school students who attempted suicide. The analysis was conducted using Path analysis, the Bootstrapping method, Phantom variable and Multiple group analysis by AMOSS using the IBM SPSS 23 and IBM SPSS AMOS 23 programs with 820 middle school students who attempted suicide in the past 12 months using the raw data of the Korea Risk Behavior Web-Based Survey (2016). In the relationship between perceived stress and perceived subjective health, the indirect effect of relief from fatigue through sleep and perceived subjective health (${\beta}=-.12$, p=.003) was statistically significant. The difference in the magnitude of the two indirect effects was found to be greater for the subjective health status than for relief from fatigue through sleep (difference = .02, p=.028) and the effects were greater for the males (${\beta}=.44$, p <.001) than for the females (${\beta}=.23$, p<.001). Based on the findings, it is necessary to develop and apply an educational program that includes the factors that contribute to improving the happiness of middle school students.

The Mediating Effects of Internalized Shame and Rejection Sensitivity in the Relationship Between Childhood Trauma and Relationship Addiction (아동기 외상과 관계중독 간 관계에서 내면화된 수치심과 거절민감성의 매개효과)

  • Song, Yeon-Joo;Ha, Moon-Sun
    • Korean Journal of Culture and Social Issue
    • /
    • v.26 no.2
    • /
    • pp.99-119
    • /
    • 2020
  • The purpose of this study was to construct and test a hypothetical model about impact of childhood trauma on Relationship Addiction of Korean adults the multiple mediating effects of rejection sensitivity and internalized shame. A purposive sample of 465 Korean adults was recruited from three provincial areas. The collected data were then analyzed using SPSS 23.0 and AMOS 23.0 programs. For data analysis, descriptive statistics and structural equation modeling were performed. Multiple mediating effects analysis using phantom variable and bootstrapping were implemented to verify the mediating effect of the research model. We found no significant direct effect of childhood trauma on relationship addiction, but the effects of childhood trauma on Relationship Addiction were successively multi-mediated by internalized shame and rejection sensitivity (B=.265, p<.01), and single-mediated by internalized shame (B=.496, p<.01). Based on the results of this study, it can be suggested that in order to prevent relationship addiction of adults, it is necessary to first explore whether he has experienced childhood trauma and thereby has not only internalized shame but also rejection sensitivity.

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF