• Title/Summary/Keyword: Phantom limb

Search Result 17, Processing Time 0.022 seconds

A Study on the Fabrication of bone Model X-ray Phantom Using CT Data and 3D Printing Technology (CT 데이터와 3D 프린팅 기술을 이용한 뼈 모형 X선 팬텀 제작에 관한 연구)

  • Yun, Myeong Seong;Han, Dong-Kyoon;Kim, Yeon-Min;Yoon, Joon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.879-886
    • /
    • 2018
  • A 3-dimensional (D) printer is a device capable of outputting a three-dimensional solid object based on data modeled in a computer. These features are utilized in the bone model X - ray phantom production etc using CT data by fusing with the radiation science field. A bone model phantom was made using data obtained by CT scan of an existing Pelvis phantom, using PLA, Wood, XT-CF20, Glow fill, Steel filaments which are materials of Fused Filament Fabrication (FFF) 3D printer.Measure Hounsfield Unit (HU) with images obtained by CT scan of the existing Pelvis phantom and five material phantoms made with 3D printer under the same conditions,SI and SNR were measured using a diagnostic X-ray generator, and each phantom was compared and analyzed.As a result, the X - ray phantom in the X - ray examination condition of the limb was found to be most suitable for the glow fill filament.The characteristics of the filament can be known to the base of this research and the practicality of X - ray phantom fabrication was confirmed.

The Effect of Tourniquet Inflation on Neural Functions: A Volunteer Study (정상 성인에서 구혈대에 의한 신경기능의 변화)

  • Jun, Hee-Jeong;Choi, Yoon;Jung, Heon-Seok;Kim, Tae-Yop;Jung, Seong-Yang;Leem, Joong-Woo
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.16-20
    • /
    • 1999
  • Background: Tourniquet pain has important impacts on anesthesia. Tourniquet pain and accompanying cardiovascular changes are important factors that make patients in distress during anesthesia. As tourniquet pain may be modified by anesthesia, a study on the changes in the neural functions by tourniquet inflation in normal volunteers is important. Methods: Time-dependent changes in tourniquet pain, heart rate, phantom limb sensation, motor function, pain to pressure on upper extremity of 10 healthy and unpremedied volunteers were measured. Each parameter were measured every 5 minutes starting from 10 minutes before inflation to 15 minutes after deflation of tourniquet. Tourniquet was deflated when the subject felt unbearable pain (score 100 with visual analog scale). Results: Subjects manifested time-dependent pain responses to tourniquet inflation, characterized by increase in VAS, systolic and diastolic blood pressure. Mean duration of tourniquet inflation was 36.4 minutes, volunteers experienced motor paralysis at 27.6 minutes and sensory loss at 33.1 minutes. Pain to pressure decreased over time in both arms. The degree of decrease was greater in the arm on which tourniquet was applied than that in the non-applied arm. Phantom limb sensation occurred in 3 subjects. Conclusions: This study demonstrated dynamic changes in the neural functions during tourniquet inflation period. Tourniquet-induced pain and resultant hypertension occurred in all subjects. Appropriate anesthetic management is needed for the surgery using tourniquet.

  • PDF

An Unexpected Improvement of the Symptom from Herniated Intervertebral Disc during Trial of Spinal Cord Stimulation for the Post-herpetic Neuralgia -A case report- (대상포진 후 신경통에 시행된 실험적 척수자극술시 예측치 못한 추간판 탈출증 증상의 개선 -증례 보고-)

  • Ahn, Jae-Seok;Han, Seok-Hee;Kim, Tae-Hyeong;Park, Hahck-Soo;Lim, Young-Jin;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.14 no.1
    • /
    • pp.110-113
    • /
    • 2001
  • In controlling chronic intractable pains, the current therapeutic methods used are exercise, over the counter medication, cognitive-behavioral therapy, opioid medication, neural blockade, operation, etc., spinal cord stimulation being the last resort. Spinal cord stimulation was initiated when Shearly and others clinically tested the Gate control theory of Melzack and Wall. This had triggered the advancement of theoretic research on the mechanism and hardware necessary and has resulted in an accumulation of clinical experiences. This is known to be effective for treating sympathetic pain, arachnoiditis, failed back pain syndrome, radiculopathy, peripheral vascular disease, phantom limb syndrome, post-herpetic neuralgia, peripheral neuropathy, and angina pectoris. This report describes our experience in experimental spinal cord stimulation in patients with simultaneous post-herpetic neuralgia and herniated intervertebral disc. There wasn't any improvement in the post-herpetic neuralgia but the symptoms of a herniated intervertebral disc was much ameliorated. This was quite an unexpected result. The patient's back pain returned when the stimulation stopped.

  • PDF

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

Variables that Affect the Satisfaction of Brazilian Women with External Breast Prostheses after Mastectomy

  • Borghesan, Deise Helena Pelloso;Gravena, Angela Andreia Franca;Lopes, Tiara Cristina Romeiro;Brischiliari, Sheila Cristina Rocha;Demitto, Marcela de Oliveira;Agnolo, Catia Millene Dell;Carvalho, Maria Dalva de Barros;Pelloso, Sandra Marisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9631-9634
    • /
    • 2014
  • Background: : In 2012, the breast cancer estimate worldwide stood at 1.67 million new cases, these accounting for 25% of all types of cancer diagnosed in women. For 2014, 57,120 new cases are expected, with a risk estimated at 56.1 cases for every 100,000 women. The objective of this study was to analyze the satisfaction regarding the use of external breast prostheses by women undergoing mastectomy. Materials and Methods: This cross-sectional study was conducted with 76 women who used an external breast prosthesis (EBP), registered in the services of the Cuiaba Center for Comprehensive Rehabilitation, Mato Grosso, Brazil, from 2009 to 2012. Data were collected from the records of women who had requested the opening of a process of external breast prosthesis concession. Results: Satisfaction with the EBP was identified in 56.6% of the women. Those satisfied with the EBP reported that its weight was not annoying (p<0.01). Although the women felt body sensations of stitches, pains, pulling, dormancy and phantom limb, they are satisfied with the EBP. The variable related to the displacement of the breast prosthesis during activity of everyday life has demonstrated that even though the women have reported the possibility of displacements, they are satisfied with the EBP. The satisfaction with the use of external breast prosthesis did not affect the sexuality of the women with mastectomy. Conclusions: Learning the specificities of the EBP, taking into consideration the satisfaction of its use, allows the rehabilitation team, by listening to their clientele more attentively, following up this woman throughout her life journey, supporting and guiding the best way of use, with an eye to her personal, emotional and social life, as well as to her self-esteem.

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.