• 제목/요약/키워드: Phantom dosimeter

검색결과 163건 처리시간 0.024초

Effective dose from direct and indirect digital panoramic units

  • Lee, Gun-Sun;Kim, Jin-Soo;Seo, Yo-Seob;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.77-84
    • /
    • 2013
  • Purpose: This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Materials and Methods: Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. Results: The effective doses of the 4 digital panoramic units ranged between $8.9{\mu}Sv$ and $37.8{\mu}Sv$. By using the head phantom, the effective doses from the direct digital panoramic units ($37.8{\mu}Sv$, $27.6{\mu}Sv$) were higher than those from the indirect units ($8.9{\mu}Sv$, $15.9{\mu}Sv$). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. Conclusion: To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

치료용 전자선 계측을 위한 1차원 광섬유 방사선량계의 제작 및 특성분석 (Fabrication and Characterization of a One-dimensional Fiber-optic Dosimeter for Electron Beam Therapy Dosimetry)

  • 장경원;조동현;신상훈;유욱재;전재훈;이봉수;문주현;박병기
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.285-290
    • /
    • 2008
  • 본 연구를 통하여 개발된 1차원 광섬유 방사선량계는 PMMA 팬텀에 10개의 광섬유 방사선 선세를 배열하여 제작하였다. 1차원 광섬유 방사선량계를 구성하는 각각의 광섬유 방사선 센서는 플라스틱 광섬유와 유기섬광체로 구성되어 있다. 각각의 유기섬광체는 치료용 선형가속기에서 발생되는 고 에너지 방사선에 의해 섬광빛을 방출하고 방출된 섬광빛은 플라스틱 광섬유를 통하여 광 계측장비인 다채널의 포토다이오드 증폭 시스템으로 전달된다. 본 연구에서는 1차원 광섬유 방사선량계를 이용하여 에너지와 조사야의 크기에 따른 치료용 전자선의 1차원적 선량분포를 측정하였고 섬광체의 광신호 측정에 있어 방해요소로 작용하는 체렌코프 빛을 전자선의 입사각도에 따라 계측 및 분석하였다. 또한 PMMA 팬텀의 깊이에 따른 선량을 계측함으로써 3차원적 심부선량백분율을 측정하였고 그에 따른 등선량곡선을 도시화하였다. 본 연구를 통하여 개발된 1차원 광섬유 방사선량계는 고 분해능, 실시간 측정, 쉬운 보정 등 많은 장점을 가지고 있다.

  • PDF

방사선 검출기용 PET 박막의 에너지 의존성 (Energy Dependancy of the Polyethylene Terephthalate Film for Radiation Detector)

  • 백금문;김건중;김왕곤;홍진웅;이병용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.71-74
    • /
    • 2002
  • Currently small and accurate dosimeters are on the rise. In this study, the feasibility and energy dependency of the electret dosimeter that made of PET (polyethylene terephtalate) were observed by irradiating 4, 6, 15 MV photon beams from the clinical linear accelerator to develop a dosimeter for the clinical field. $10{\times}10cm$ field size of the photon beams were irradiated to the electret dosimeter where the 2.5 cm depth in the polystylene phantom from 100 cm SSD, while 300 DCV was applied to the electret dosimeter. The result showed that the absorbed dose was proportional to the charge linearly, and the volume of a dosimeter could be reduced and the signals were high enough. According to this study, it was found that the polymer electret detector could be produced as a large quantity with a small cost and showed the feasibility of a realtime measurement.

  • PDF

자체 제작한 근접방사선치료용 다목적 팬텀의 유용성 평가 (Effectiveness of a Custom-made Multi Purpose Brachytherapy Phantom)

  • 장인기;이정진;김완선
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.119-125
    • /
    • 2006
  • 목 적: 본 연구에서는 근접치료 시 선량기준점에서 선량을 정확히 분석하고자 근접방사선치료용 다목적 팬텀(Multi Purpose Brachytherapy Phantom, MPBP)을 제작하여 그 유용성을 평가하고자 하였다. 대상 및 방법: 자체 제작된 근접방사선치료용 다목적 팬텀(MPBP)에서 다기능삽입구(Multi Function Applicator, MFA)를 이용하여 치료 시와 동일한 조건을 재현한 후 열형광선량계(TLD)를 이용하여 전산화 치료계획 장치에서 계산된 좌표와 동일한 기준점에서 선량을 측정하였다. 측정 대상은 근접방사선 치료환자 중 탄뎀(tandem)과 난형체(ovoid)를 사용한 자궁경부암 환자 4명을 대상으로 환자 당 5회씩 총 20회 A point와 B point 그리고 방광에서 선량을 측정하였다. 결 과: MPBP에서 TLD의 측정 결과는 A Point에서 측정한 환자의 상대오차가 각각 -3.2%, -0.2%, 0%, 3.8%를 보였고, B point에서는 -1.4%, -1.4%, 2.4%, 4.0%를 보였다. 그리고 방광에서는 1.3%, 2%, 5.4%, 7.15%의 상대오차를 나타내었다. 결 론: 자체 제작된 근접치료용 다목적 팬텀(MPBP)은 다기능삽입구(MFA)를 사용하여 치료 시와 동일한 조건에서 선량측정의 재현성을 이룰 수 있었고, A, B point지점과 방광의 선량을 정확히 분석할 수 있었다. 따라서 본 연구에서 제작된 근접방사선치료용 다목적 팬텀은 기준점 선량분석에 매우 유용한 것으로 판단된다.

  • PDF

두개부, 흉부, 복부검사 시 반도체 선량계와 면적 선량계를 이용한 선량 값의 측정 및 비교 (Comparisons and Measurements the Dose Value Using the Semiconductor Dosimeter and Dose Area Product Dosimeter in Skull, Chest and Abdomen)

  • 김기원;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권2호
    • /
    • pp.101-106
    • /
    • 2015
  • 최근에 방사선을 이용한 검사들은 환자들이 받는 피폭선량에 대한 관심이 증대하고 있으며, 이러한 방사선을 이용한 방사선사들은 X-선 검사 시 환자에게 조사되는 피폭선량을 인지하여 영상의 질 저하 없이 환자의 피폭선량경감에 대하여 끊임없이 노력해야 한다. 외국의 경우 일반촬영검사들의 피폭선량기준치로 면적선량계와 표면입사선량계에 의하여 선량관리를 하고 있다. 이에 본 논문은 모의팬텀을 이용하여 일반촬영검사들 중 두 개부 전후방 촬영, 흉부 후전방 촬영, 복부 전후방 촬영을 중심으로 면적선량계와 반도체 선량계를 이용하여 면적선량과 표면선량을 비교 측정하였으며, 그 결과 면적선량계와 반도체선량계와의 측정차이는 없었다.

광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정 (Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter)

  • 장경원;조동현;유욱재;서정기;허지연;이봉수;신상훈;박병기;김신
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.52-57
    • /
    • 2010
  • In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And ${\gamma}$-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

광자선의 소조사면에서의 3차원적 선량 측정 (3-Dimensional Dosimetry of Small Field Photon Beam)

  • 장지선;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.54-61
    • /
    • 2012
  • 중합체 겔 선량계를 제작하여 사이버나이프의 광자선의 소조사면에서의 3차원적 선량측정 실험을 수행하였다. 겔 선량계는 아크릴로 제작된 두경부 팬텀내에 설치하여 선량측정에 사용하였다. 두경부 팬텀의 영상은 사이버나이프의 두경부 환자 치료를 위해 사용하는 전산화단층촬영장치(CT)의 프로토콜을 사용하여 획득하였고 치료계획 시스템에 전달되었다. 겔 선량계에 치료계획에서 수립한 방사선을 조사하였으며, 24시간 경과 후에 선량분석을 위하여 3.0T 자기공명영상장치(MRI)로 영상을 획득하였다. 측정된 겔 팬텀의 선량분포는 MATLAB을 이용하여 분석하였고 측정된 결과를 치료계획에서의 계산값과 비교하였다. 선량분포는 축상(axial) 방향의 등선량곡선의 80% 고선량 영역에서 치료계획 선량곡선과 측정된 선량곡선과의 차이가 0.76 mm이었으며, 40% 저선량 영역에서는 차이가 1.29 mm로 저선량 영역보다 고 선량영역에서 잘 일치함을 알 수 있었다. 본 연구에서 중합체 겔 선량계와 자기공명영상을 이용하여 소조사면에 대해 3차원적으로 선량을 분석할 수 있을 뿐 아니라 치료방사선 정도관리에도 활용될 수 있는 가능성을 확인하였다.

반도체 검출기에 의한 전자선 선량분포에 관한 연구 (A Study on Dose Distribution of Electron Beams by Semiconductor Detector)

  • 강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.19-25
    • /
    • 1984
  • There is not yet an universal method of electron dosimetry. The Authors measured dose distributions of the electron beams from Clinac-18 by means of silicon detector connected to X-Y recorder, and compared them in water phantom with dose distributions measured by film and ion chamber, both inserted in polystyrene phantom. The results are as followings, 1. Dose in build-up region increased with the field size for all energy, and depth dose profiles of $6{\sim}12MeV$ beam under the depth of maximum dose were independent of field size, but those of 15 and 18 MeV beam were dependent on the field size. 2. The widths of penumbra by semiconductor detector were narrower than those by film for same energy beam. 3. Depth dose profiles by three different dosimeter did not coincide each other. In the build-up region, dose by semiconductor detector was lower than that by any other dosimeter.

  • PDF

제작된 선량 검증용 IMRT 팬텀의 몬테칼로 시뮬레이션: 예비적 연구 (A Monte Carlo Simulation for the Newly Developed Head-and-Neck IMRT Phantom: a Pilot Study)

  • 강세권;정광호;주라형;조병철;오도훈;김수산;김경주;배훈식;한영이;신은혁;박성호;임천일
    • 한국의학물리학회지:의학물리
    • /
    • 제18권3호
    • /
    • pp.126-133
    • /
    • 2007
  • 세기조절방사선치료(Intensity modulated radiation therapy, IMRT) 선량의 정확도를 원격으로 점검할 수 있는 시스템 구축을 목적으로, 두경부용 팬텀을 제작하였다. 팬텀은 공기 및 뼈 구조물의 교체 장착을 통해, 균질 혹은 비균질 팬텀으로 이용할 수 있다. 일차적으로 단일 빔 및 세 빔의 조사에 대한 몬테칼로(Monte Carlo, MC) 전산모사를 시행하고, 이온 전리함 및 열형광선량계(thermoluminescent dosimeter, TLD)를 이용한 측정과 비교하였다. TLD의 판독은 독립된 두 기관에서 수행하였다. 단일 빔의 경우, 균질 및 비균질 팬텀에 대한 이온 전리함 측정 결과는 MC전산모사 결과와 대체로 2% 수준에서 일치하였으며, TLD 의 경우에는 기관에 따라 2% 혹은 7%수준의 차이를 보였다. 세 빔을 이용한 비교의 경우에는, 이온 전리함은 -5% 수준, TLD의 경우에는 $+2{\sim}+3%$ 수준의 차이를 보였다. 원격 선량 검증을 위해서는 TLD 판독의 신뢰도 향상이 필요한 것으로 판단되었다. MC 전산모사는 새로운 팬텀 개발 시에, 선량 측정값의 신뢰도 확보에 이용될 수 있다.

  • PDF

140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가 (Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield)

  • 김지영;이왕희;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.