• 제목/요약/키워드: Phantom Test

검색결과 303건 처리시간 0.033초

Extended Technology Acceptance Model for Enhanced Distribution Strategies to Online Learning: Application of Phantom Approach

  • Izzat ISMAIL;Asyraf AFTHANORHAN;Noor Aina Amirah MOHAMAD NOOR;Nurul Aisyah Awanis A RAHIM;Sheikh Ahmad Faiz Sheikh Ahmad TAJUDDIN;Muhammad Takiyuddin Abdul GHANI
    • 유통과학연구
    • /
    • 제22권4호
    • /
    • pp.1-10
    • /
    • 2024
  • Purpose: This study is aimed to introduce the application of phantom approach with structural equation modelling method for online learning. By integrating these innovative methodologies, the research seeks to advance the understanding of how the phantom approach can effectively complement and augment structural equation modeling techniques. Research design, data and methodology: A theoretical framework of Technology Acceptance Model (TAM) was modified and updated. A questionnaire was developed and used to extract information from 189 instructors who used online learning as their primary medium. The Covariance Based Structural Equation Modelling (CBSEM) was applied to test the direct effects and the phantom approach is used to handle the 2 mediators in the model. Results:social influence, perceived usefulness, and perceived ease of use exerted discernible impacts on instructors' intentionsto engage in online learning. These findings illuminate the intricate dynamics influencing instructor behavior within the realm of online education, underscoring the significance of various factors in shaping their intentions. Conclusions: In additions, the perceived usefulness and perceived ease of use had mediated the effect of social influence and instructor intention using phantom approach. Therefore, one can have concluded that this modified model was also confirmed, thereby reinforcing distribution strategies to online learning and overall education presence.

역투사 알고리듬과 비촛점 트랜스듀서를 적용한 광음향 단층영상 장치개발과 팬텀실험 (Phantom Evaluation and Development of Photoacoustic Tomography Imaging System using Unfocused Ultrasound Transducer and Back-Projection Algorithm)

  • 유상훈;김도현;송철규
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2349-2351
    • /
    • 2010
  • Photo Acoustic Tomography (PAT) is a hybrid imaging modality which combines high contrast of optical imaging and spatial resolution of ultrasound imaging, thus it is suitable to image biological tissue noninvasively. Laser-induced photoacoustic signals were measured from a sample by means of an unfocused ultrasound transducer, then PAT image was reconstructed based on a universal back-projection algorithm. To evaluate the feasibility of our system, phantom test was performed, consequently, the PAT images obtained using our system showed highly analogous shape and volume with those of the phantom. This result demonstrated that our system can provide a powerful tool for imaging the substructure of biological tissue in non-invasive manner.

감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가 (Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image)

  • 김종필;윤석환;임정진;우재룡
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.30-35
    • /
    • 2011
  • 현재 분해능 향상을 위한 프로그램인 Wide beam reconstruction (WBR: UltraSPECT, Israel) 을 사용하고 있다. WBR에 속해있는 Xact-Bone은 Planar영상과 Single photon emission computed tomography (SPECT) 영상의 분해능과 대조도를 향상시켜 상당한 영상의 질 향상에 도움을 준다고 보고 되어있다. 본 연구는 Xact-Bone의 임상적용에 대한 유용성을 알아보고자 한다. Xact-Bone에서의 유용성 평가는 분해능 평가와 Contrast Ratio를 비교분석하였다. Planar영상에서의 분해능 평가는 capillary tube를 이용하여 Full width at half maximum (FWHM)을 구하였고, Contrast Ratio분석은 2010년 1월부터 2010년 10월까지 bone scan 검사를 위해 본원에 내원한 50명의 환자 Xact-Bone의 사용 전 후 영상에서 Bone and Soft tissue (B/S) ratio 값을 비교 평가하였다. SPECT영상에서의 분해능 평가는 Triple Line Source Phantom을 이용하여 FWHM을 구하였고, Contrast Ratio 비교 분석은 NEMA IEC Body Phantom과 Standard Jaszczak Phantom을 이용하여 획득한 영상을 각각 Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM), Xact-Bone으로 재구성하여 비교하였다. Planar영상에서의 유용성 평가는 capillary tube를 이용한 실험결과, FWHM은 기존의 Planar영상보다 WBR의 Xact-Bone 프로그램을 이용한 재구성 영상에서 약 20% 향상되었으며, B/S ratio값도 약 15% 향상되었다. SPECT영상의 유용성 평가는 Triple line Source Phantom을 이용한 실험결과, FWHM은 Xact-Bone이 FBP, OSEM 기법보다 각각 20%, 10% 향상되었다. 또한 NEMA IEC body Phantom을 이용한 Contrast Ratio 비교분석결과 각각 20%, 10% 향상되었고, Standard Jaszczak Phantom을 이용한 Contrast Ratio 비교분석 결과는 각각 90%, 50% 향상되었다. WBR의 Xact-bone 프로그램을 이용한 Planar 영상에서는 사용하지 않은 경우와 비교하였을 경우 상당한 영상의 분해능과 Contrast Ratio가 향상됨을 알 수 있었고, SPECT영상에서 기존의 FBP, OSEM 영상재구성 방법보다 분해능, Contrast Ratio가 향상됨을 알 수 있었다. 이에 WBR의 Xact-Bone을 이용함으로써 영상의 질적 향상이 기대되는 바이다. 하지만, 새로운 소프트웨어 도입시 병원의 특성에 맞는 protocol 과 임상적용이 필요하다고 사료된다.

  • PDF

레이저흡수분광법(TDLAS) 기반 가스온도분포 산정을 위한 상호상관계산 알고리듬 개발 (Developments of a Cross-Correlation Calculation Algorithm for Gas Temperature Distributions Based on TDLAS)

  • 최두원;김광남;조경래;심준환;김동혁;;도덕희
    • 한국수소및신에너지학회논문집
    • /
    • 제27권1호
    • /
    • pp.127-134
    • /
    • 2016
  • Most of reconstruction algorithms for the calculation of temperature distributions in CT (computed tomography)-TDLAS (tunable diode laser absorption spectroscopy) are based upon two-line thermometry method. This method gives unstable calculation convergence due to signal noise, bias error, and signal mis-matches. In this study, a new reconstruction algorithm based on cross-correlation for temperature calculation is proposed. The patterns of the optical signals at all wave lengths were used to reconstruct the temperature distribution. Numerical test has been made using phantom temperature distributions. Using these phantom temperature data, absorption spectra for all wave lengths were constructed, and these spectra were regarded as the signals that would be obtained in an actual experiments. Using these virtually generated experimental signals, temperature distribution was once again reconstructed, and was compared with those of the original phantom data. Calculation errors obtained by the newly proposed algorithm were slightly large at high temperatures with small errors at low temperature.

한방부인과 임상실습교육에서 초음파 팬텀의 활용과 효과 (The Use and Educational Effect of Ultrasonic Phantom in Korean Medicine Obstetrics and Gynecology Clinical Practice Education)

  • 양승정;조성희
    • 대한한방부인과학회지
    • /
    • 제35권2호
    • /
    • pp.16-27
    • /
    • 2022
  • Objectives: The purpose of this study is to analyze educational effect of ultrasound examination training with ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology. Methods: All 4th grade students in 2021 and 2022 of school of Korean Medicine, Dong-Shin University must be trained in the department of Korean Medicine Obstetrics and Gynecology according to ultrasound examination training guideline including Objective Structured Clinical Examination (OSCE). After completing ultrasound examination training, we distributed questionnaires to them about a confidence before OSCE and after OSCE, difficulty in using ultrasound, ultrasound reading, difficulty with probe manipulation and computer operation, ultrasound understanding, clinical usefulness. And then, we analyzed the related factors including descriptive statistics, frequency analysis, student's t-test and paired t-test by SPSS 12.0. Results: Confidence in using ultrasound showed differences among students by gender and year, but it was not statistically significant. The difficulty of ultrasound use and ultrasound reading was at a moderate level, and the gender difference was not significant, and the difference between the practical students by year was statistically significant. The difficulty of the operation of the ultrasonic probe was at a normal level, and the difference between the students in practice by gender and year was not statistically significant. Although they answered that they had a very good understanding of the use of ultrasound, there was a gender difference and it was statistically significant, and practical students by year was not statistically significant. They answered that the effect on clinical use was very sufficient, but it was not statistically significant. The appropriateness of the practice time was evaluated at a moderate level. Conclusions: The use and educational effect of ultrasound examination using ultrasonic phantom in the department of Korean Medicine Obstetrics and Gynecology clinical practice education was very effective.

Adaptive Statistical Iterative Reconstruction 기법을 이용한 Bone SPECT/CT 검사에서 피폭량 감소 방안 (Reducing Dose in SPECT/CT Using Adaptive Statistical Iterative Reconstruction Technique)

  • 최진욱;최현준;박찬록;조성욱;김진의;이재성;이동수
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.134-139
    • /
    • 2014
  • ASIR기법은 statistical noise modeling을 사용하여 CT image를 reconstruction하는 방법으로, mA를 낮춰도 이미지 질을 보전하며 noise reduction 효과가 있다고 알려져 왔다. 본 논문은 본원에서 주로 하는 bone SPECT/CT에 ASIR 기법을 적용하여 이미지를 평가하였다. GE의 Discorvery 670을 이용하여 120 kVp, 100 mA를 기준으로 mA를 변화시켜서 ASIR의 적용 전과 적용 후 영상을 비교하였다(ASIR level: 20-80%). Anthropomorphic phantom으로 ASIR (%)의 변화에 따른 SPECT image의 감쇠 보정 정도를 측정하였다. 두번째로 ACR phantom으로 CT image의 CNR, image noise, spatial resolution을 평가하였다. 세 번째로 lower torso phantom을 이용하여 spine에 최적화할 수 있는 ASIR level을 선택한 후 2명의 bone SPECT/CT follow up 환자에게 ASIR를 적용하여 영상을 획득한 후 5년 이상의 경험이 있는 10명의 방사선사에게 blind test를 시행하였다. SPECT의 영상의 감쇠 보정 정도는 ASIR의 변화와는 무관하게 모두 유의한 차이가 없었다(P>0.05). ASIR을 적용했을 때 CT image의 noise는 mA의 변화에 따라 최소 17%에서 최대 52%까지 감소하였다. ASIR를 적용하지 않았을 때 CNR은 40 mA에서 0.42를 보여준 반면 ASIR를 적용한 40 mA (ASIR 60%)에서도 0.8 이상을 유지하였다. High contrast 영역의 비교에서는 ASIR 적용과 상관없이 40 mA까지 12 lp/cm 영역을 구별할 수 있었다. Lower torso phantom의 spine image에서 100 mA image와 육안적으로 비슷한 ASIR level은 60% (40 mA) 정도였고, bone SPECT/CT에 적용한 후 blind test에서 육안적으로 ASIR를 적용하지 않았을 때와 차이를 구별하지 못하였다. 본 논문의 결과는 SPECT/CT에서 ASIR 기법을 사용했을 때 SPECT와 CT image의 특별한 영상의 질 저하 없이 radiation dose를 줄일 수 있다는 것을 보여준다. 또한 관심부위가 bone에 한정되어 있는 bone SPECT/CT 특성상 더 높은 ASIR level도 가능할 것으로 사료된다.

  • PDF

Metal artifact 감소를 위한 CT simulator 영상 재구성의 유용성 평가 (Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact)

  • 최지훈;박진홍;최병돈;원희수;장남준;구장현;홍주완
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.191-197
    • /
    • 2014
  • 목 적 : CT simulation 시 고 밀도 인공물에 의해 발생된 metal artifact는 주변조직의 관찰능력 감소 및 CT number 변화에 영향을 미치게 된다. 본 연구에서는 CT 촬영 시 Metal Artifact Reduction for Orthopedic implants(O-MAR)의 유용성을 평가해 보고자 한다. 대상 및 방법 : CT simulator를 이용하여 Gammex phantom과 Rando phantom의 original 영상, 고 밀도 인공물을 삽입 후 획득한 non O-MAR 영상과 O-MAR 적용 영상을 획득하였다. CT 영상 평가를 위해 Gammex phantom CT 영상 내 5개 조직과 artifact 영향을 직접 받는 3개 지점에 관심영역(region of interest, ROI)을 각각 설정하고, CT number와 노이즈(standard deviation, SD)를 평균값으로 비교, 분석하였다. 고 밀도 인공물 주변조직의 CT number 변화에 따른 선량변화 확인을 위해 전산화치료계획시스템 Eclipse를 이용하여 Rando phantom CT 영상 3곳에 원기둥 체적을 형성하였다. 치료계획은 6 MV 광자선, 7개 조사면, 조사야 $15{\time}15cm$, 1회당 처방선량 100 cGy를 적용하여 수립하고 평균선량을 비교, 분석하였다. 두 실험 모두 original 영상을 기준으로 분석하였다. 결 과 : Gammex phantom을 이용한 영상평가 실험에서 각 영상별 5개 조직의 CT number 차이는 작았으며, artifact 영향을 직접 받는 3개 지점은 O-MAR 적용 시 original 영상과 유사하게 나타났다. 그리고 O-MAR 적용 시 8개 지점의 SD는 non O-MAR 영상보다 모두 감소되었다. Rando phantom을 이용한 선량변화 실험 또한 O-MAR 적용 시 original 영상과 유사하게 나타났다. 결 론 : O-MAR 적용 시 고 밀도 인공물 artifact로 인한 영상 왜곡 및 SD 감소로 영상의 질이 향상되었으며 CT number 보정에 유용하였다. 이는 체표윤곽도(contour) 생성 및 치료계획 수립에 이점이 있을 것이라 사료된다.

PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구 (The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT)

  • 도용호;송호준;이형진;이홍재;김진의
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.29-34
    • /
    • 2012
  • Siemens사의 CT 선량 감소 소프트웨어인 IRIS의 적용을 통하여 CT 선량 감소 시 노이즈 감소 효과와 해상력의 보존 그리고 ACCT에 IRIS 각 kernel의 적용 시 SUV 변화를 확인하는데 목적을 두었다. Biograph mCT 40 slice 스캐너를 이용하여 AAPM CT performance phantom, Anthropomorphic chest phantom을 관전압 120 kVp로 고정하고 100-10 mAs까지 15%감소하여 스캔 후 FBP, IRIS 각 kernel을 적용하여 재구성 하여 영상의 노이즈, 해상력, 영상 평가를 시행하였다. NEMA IEC body phantom을 이용하여 55.5 MBq를 background에 주입하고 열소와 배후 방사의 비를 8:1이 되도록 모형을 제작하였다. 120 kVp, 50 mAs 조건으로 1분, 2분, 3분, 4분 스캔하여 영상을 획득한 후 ACCT에 IRIS 각 kernel을 적용하여 기존 FBP 방식을 적용한 SUV와의 평가를 시행하였다. IRIS의 적용 시 기존 FBP 방식에 비하여 45% 선량을 감소하였음에도 불구하고 해상력 저하 없는 노이즈 감소 효과가 확인 되었으며 SUV 평가 실험에서 IRIS의 I70f kernel을 제외하고는 기존 FBP 방식을 통하여 획득된 SUV와 유의한 차이가 나타나지 않았다. 본 연구를 통하여 IRIS 적용 시 기존 FBP 방식에 비하여 CT 피폭선량 감소와 해상력 저하 없는 노이즈 감소 효과를 입증하였으며 IRIS kernel의 적절한 적용을 통하여 PET/CT 검사 시 환자 피폭선량 감소는 물론 FBP 방식에 비하여 우수한 영상의 획득이 가능할 것이라 사료된다.

  • PDF

초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로) (Performance Testing of Medical US Equipment Using US Phantom(ATS-539) (Focusing on Daegu Region))

  • 김도형;권덕문
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권4호
    • /
    • pp.295-305
    • /
    • 2014
  • 초음파장비는 인체 병변의 유무를 검사하는 의료장비로서 정확한 의료영상정보를 제공해야 한다. 의료용 초음파장비 성능측정을 위해 초음파팬텀(ATS-539)의 측정방법과 기준으로 대구지역 의료기관의 초음파장비 성능의 실태를 알아보고, 초음파팬텀을 이용한 장비성능검사의 기본 자료를 제시하고자 한다. 초음파팬텀의 측정방법과 기준인 불응영역, 수직거리정확성측정, 수평거리정확성측정, 축방향/측 해상도, 민감도, 회색조 및 동적범위를 사용하였다. 그리고 국소영역, 기능적 해상도를 추가해서 총 8개 항목으로 측정하고 평가하였다. 결과분석을 위해 평균, 표준편차, 빈도 및 백분율을 제시하였고, Mann-Whiney test와 t-test를 실시하였으며, 유의수준은 0.05로 하였다. 본 연구의 결과는 다음과 같다. 1. 초음파팬텀 측정결과는 총 35대 중 합격은 31대 88.6%, 불합격은 4대 11.4%였다. 2. 합격기준이 제시되지 않은 국소영역과 기능적 해상도 4 mm가 통계적으로 유의하게 합격군과 불합격군간의 평균의 차이가 있었다. 3. 불합격한 장비의 평균 사용연수는 7.25년으로 합격한 장비 4.13년보다 차이가 있었다. 대구지역내 임상에 실제 사용되는 의료용 초음파장비의 성능 실태를 파악해 보았고, 합격기준이 제시되지 않은 2항목에 대한 기초자료를 제시하였다. 초음파장비 사용연한이 장비성능과 관계가 있었다. 의료용 초음파장비 성능검사를 위한 초음파팬텀측정은 장비의 최적의 성능 유지를 위하여 제도적인 대책 마련이 필요하다.

뇌정위 방사선수술 시스템을 위한 자기공명영상의 공간적 왜곡의 측정 : 모형실험을 통한 연구 (Assessment of Imaging Distortion in Magnetic Resonance Imaging for Stereotactic Radiosurgery: Through Phantom Study)

  • 박선원;한문희;김동규;정현태;송인찬
    • Investigative Magnetic Resonance Imaging
    • /
    • 제4권1호
    • /
    • pp.7-13
    • /
    • 2000
  • 목적: 모형실험을 통하여 자기공명영상의 공간왜곡의 정도를 영상획득방향과 펄스연쇄별로 알아보고 실험 조건에서 공간왜곡이 가장 적은 영상 획득 방향과 펄스 연쇄를 찾고자 하였다. 실험 상 얻어진 가장 공간적 왜곡이 적은 영상법은 뇌정위 방서선수술의 적용시에도 실험한 조건중 가장 공간적 왜곡이 적은 영상법으로 인체적용에 도움이 될 것으로 가정하였다. 대상 및 방법: 아클리로 만든 직육면체에 일정한 간격 (2cm)의 아크릴 원형 막대 지름 4mm)를 배치하여 자기공명영상을 위한 모형을 제작하였다. 모형의 내부를 증류수로 채운 후 Leksell 상업용 감마나이프 G-프레임을 씌우고 모형을 자기공명 영상의 중심에 놓고 축상과 관상면의 T1 SE, T2 SE, T2 FSE, MPRAGE영상을 얻은 뒤 영상분석 프로그램(Lleksell Gamma Plan, Version = 5.10)을 이용하여 공간적 왜곡의 거의 없을 것이라고 가정한 CT 영상에서 측정된 막대간의 거리의 차이를 구하고 이것이 각 영상획득 방법과 펄스 연쇄별로 차이가 나는지 또 영상의 가장자리와 중심부에서 차이가 나는지 paired student t-test를 통하여 분석하였다. MR의 각 단면 영상을 영상분석 프로그램에 인식시키는 과정에서도 프로그램에 내장되어 있는 외부 표식자의 좌표의 위치를 통해서 외부표식자의 좌표의 위치를 통해서 외부표식자를 기준으로한 영상의 공간적 왜곡의 정도가 자동으로 측정된다. 결과: 자기공명영상의 공간적 왜곡은 횡단면 영상에서는 감마나이트의 G-프레임의 외부표식자에 의하여 측정된 결과와 모형실험을 통하여 얻어진 결과에서 모두 뇌정위방서선수술에 이용하기에 허용할 만한 1.5mm 이하의 적은 수준의 왜곡 값을 지니고 있었다. 관상면의 자기공명영상은 외부표식자에 의해 왜곡을 측정했을 때, 감마나이프에 적용하기에는 1.5mm 이상의 공간 왜곡값을 보였으나 왜부표식자에 의한 좌표를 통해 구해진 모형실험의 결과에서는 1.5mm 이하로 공간적 왜곡이 오히려 보정되는 결과를 보였다. 결론: 이 실험을 통하여 임상적으로 주로 사용되는 펄스연쇄와 영상획득방향에서 축상 3D MPRAGE기법이 가장 공간적 왜곡이 적은 영상법 임을 알 수 있었다. 현재 사용되는 MR기기의 공간왜곡의 정도는 모형실험의 결과, 1.5mm 이하 수준으로 매우 적어서 다른 영상법에 비해 매우 우수한 MR의 공간 해상력을 고려하면, 실제 인체에 적용하여 뇌정위 방사선수술시 사용항기에도 타영상기법에 비해 손색없는 영상법이 될 것으로 판단된다.

  • PDF