• 제목/요약/키워드: Petrifilm method

검색결과 17건 처리시간 0.031초

소.돼지 도체표면의 미생물학적 고찰 (Survey on the microbiological quality of meat in Seoul)

  • 변정옥;모의원;문호판;이양수;이병동
    • 한국동물위생학회지
    • /
    • 제23권2호
    • /
    • pp.105-112
    • /
    • 2000
  • This survey was conducted to evaluate the microbiological quality of raw beef and pork products from January to December in 1999. A total of 107 beef and 157 hog carcasses were collected from two abattoirs located in Seoul. The result showed that beef carcasses had an average bacterial loading around 139,000 bacteria/$\textrm{cm}^2$ of carcass surface, indicating a little bit higher count than the results reported in USA and Australian meat. However, overall hygienic status was found to be acceptable for all examined carcasses because 84.4% of product rated excellent, good or acceptable comparable to USA of 91.6% and Australia of 88%. The analysis of data on overnight-chilled to weekend-chilled carcasses indicated that the microbiological growth occurred in the chiller during the weekend chill with increases in total viable count from 130,000cfu/$\textrm{cm}^2$ to 400,000cfu/$\textrm{cm}^2$. Qualitative testing for escherichia coli, EC + MUG was used as a most probable number (MPN) method along with the petrifilm method. The average of MPN/$\textrm{cm}^2$ of E coli biotype 1 was 29MPN/$\textrm{cm}^2$ for beef carcasses and 1,100 MPN/$\textrm{cm}^2$ for hog carcasses, respectively. However, 41% of beef and 16.3% of hog carcasses were shown to be less than < 3 MPN/$\textrm{cm}^2$ in E coli biotype 1 examination. Although salmonella enteritis, S typhimurium and E coli O157:H7 were all negative, listeria monocytogenes was recovered from only one hog surface samples of the 89 carcasses tested.

  • PDF

Evaluation of the $HApS^{TM}$ Method for the Enumeration of Aerobic Microorganisms and Coliforms in Retailed Meat Samples in Korea

  • Keun-Seok Seo;Wonki Bae;So-Hyun Kim;Nam-Hoon Kwon;Ji-Yeun Kim
    • 한국식품위생안전성학회지
    • /
    • 제16권3호
    • /
    • pp.194-199
    • /
    • 2001
  • 국내에서 시판중인 230점(돈육샘플80점, 계육샘플 80점, 우육샘플 70점)의 식육 샘플에 대하여 미생물 오염수준 측정시 표준방법으로 통용되는 AOAC (the Association of Official Analytical Chemists)의 standard total aerobic count method 및 coliform count method와 국내에서 개발된 HApS$^{TM}$ (Hazard Analysis process System) method를 비교하였다. 돈육, 계육, 우육을 샘플군으로 하여 총세균수 및 대장균수를 표준방법과 HApS$^{TM}$방법으로 각각 측정하여 그 두 방법간의 상관관계를 조사하였다. 선형회귀분석 및 t-검정법의 통계적 방법을 사용하여 각 샘플군에서의 두 방법간의 상관계수(r) 및 회귀직선식을 얻었고, 각 샘플군에서 두 방법에 의한 각각의 표본평균이 주어진 유의수준($\alpha$=0.05)에서 유의한 차이를 보이지 않았다. 즉, 본 실험에 사용된 샘플에 대하여 표준방법과 HApS$^{TM}$ 방법간의 유의한 차이를 발견하지 못하였다. 그러므로 표준방법에 비하여 실험시간 및 실험방법에서 신속성 및 간편성을 지니는 HApS$^{TM}$방법은 축산식품의 총세균 및 대장균군 오염도 측정시에 표준방법을 대신할 수 있는 유용한 방법이라고 할 수 있다.

  • PDF

신선편이 엽채류의 병원성 E. coli 검출을 위한 생화학적동정법 비교 분석 (Comparison of Biochemical Identification to Detect Pathogenic Escherichia coli in Fresh Vegetables)

  • 최유경;이희영;이수민;김세정;하지명;이지연;오혜민;윤요한
    • 한국식품위생안전성학회지
    • /
    • 제31권6호
    • /
    • pp.393-398
    • /
    • 2016
  • 본 연구에서는 선택배지와 건조필름을 이용하여 신선편이 엽채류 3종(양상추, 양배추, 어린잎채소)에서 병원성 E. coli를 분리하였고, 의심집락 동정을 위해 생화학적 분석법을 사용하여 동정한 후 결과를 비교 분석하였다. 양상추 20 g, 양배추 20 g, 어린잎채소 10 g에 병원성 E. coli 혼합 균액(Enterohemorrhagic E. coli NCCP11142, Enterotoxigenic E. coli NCCP14037, Enteropathogenic E. coli NCCP14038, Enteroaggregative E. coli NCCP14039, Enteropathogenic E. coli NCCP15661)을 최종농도가 1, 2, 3 log CFU/g이 되도록 접종하였고, BPW (80~90 ml)을 넣은 후 60초 동안 균질화하여 분석하였다. 연구결과, 모든 시료에서 건조필름 시험 양성, 양상추 시료 일부(최종농도 3 log CFU/g 접종시료)를 제외한 모든 시료에서 증균배양법을 이용한 정성시험결과가 음성으로 나타났다. 증균배양과 건조필름 시험을 통해 분리한 병원성 E. coli를 이용하여 생화학적 분석을 실시한 결과, 양상추에서 분리한 병원성 E. coli의 경우, API 20E 100% (44/44), Microgen GNA 100% (44/44), Food System 66.7% (10/15)의 동정률이 나타났다. 양배추의 경우, API 20E 64.7% (22/34), Microgen GNA 50% (16/32), Food System 60% (9/15), 어린잎채소의 경우, API 20E 65.1% (28/43), Microgen GNA 62.3% (27/43), Food System 53.3% (8/15)가 병원성 E. coli로 동정되었다. 본 연구의 결과는 신선편이 엽채류에 대한 병원성 E. coli 검출법 선택에 유용하게 이용될 것으로 판단된다.

ATP Bioluminescence와 간이미생물배지를 이용한 고등학교 급식시설의 위생상태 조사연구 (Evauation of Hygienic Status of High School Foodservice using ATP Bioluminescence Assay & Microorganism Test Strips)

  • 장재선;황성희
    • 한국식품영양학회지
    • /
    • 제28권5호
    • /
    • pp.918-925
    • /
    • 2015
  • An investigation was conducted to evaluate the hygienic status of 33 high school foodservice systems in Yongin city by using hygiene management guide checklist, ATP bioluminescence assay and microbe inspection petrifilm (APC, coliform group, Staphylococcus aureus) of food utensils during use. The 22 hygiene management guide checklist items about facilities, personal hygiene, food control, distribution, washing and disinfection had good grade but there were some inadequate behaviors on observation. The inspection results showed their sanitary condition met the level B of the recommendation of Korea method, it means sanitary management system get settled but more practical CCP system was needed. ATP bioluminescence assay was conducted on surface of food facilities, ATP ranged 425~2,552 RLU on gloves, 541~70,251 RLU on apron, 1,596~88,490 RLU on working desk, 1,177~263,813 RLU on sterilizer grip, 715~32,814 RLU on sterilizer shelf, 114~619,725 RLU on refrigerator grip, 677~319,007 RLU on refrigerator shelf, 71~196,725 RLU on freezer grip, 1,535~233,375 RLU on freezer shelf. APC ranged $66.7{\pm}29.0CFU$ on freezer grip, $102.1{\pm}35.9CFU$ on refrigerator grip, $45.4{\pm}28.2CFU$ on heating cabinet grip, $58.8{\pm}40.4CFU$ on sterilizer grip, the number of coliform group ranged $5.6{\pm}4.9CFU$ on freezer grip, $9.1{\pm}8.7CFU$ on refrigerator grip, $1.2{\pm}1.1CFU$ on heating cabinet grip, $4.5{\pm}4.4CFU$ on sterilizer grip. S. aureus ranged $8.0{\pm}5.6CFU$ on freezer grip, $12.2{\pm}9.6CFU$ on refrigerator grip, $2.1{\pm}1.6CFU$ on heating cabinet grip, $11.6{\pm}6.4CFU$ on sterilizer grip.

회전형 저온 플라즈마 시스템을 이용한 분말식품의 균일한 살균 연구 (A Study of Homogeneous Sterilization of Micro-sized Food Powder by Rotatable Low-Temperature Plasma System)

  • 김명찬;박덕모;한진수;우인봉;김동후;장성은;윤찬석;김인
    • 한국식품영양학회지
    • /
    • 제31권2호
    • /
    • pp.301-307
    • /
    • 2018
  • In this study, a relatively effective process is used to sterilize Escherichia coli on the surface of micro-sized calcium citrate powder using nitrogen and argon as process gases in a low-temperature vacuum plasma treatment. The purpose of this study is to confirm and to introduce the effectiveness of homogeneous surface treatment for the sterilization of fine inorganic powder by the rotatable low-temperature RF plasma system designed by ourselves. The results of the test using 3M petrifilm showed that there were no remarkable spots in the case of the surface of plasma treated powder, whereas the untreated powder showed many blue spots, which indicating that the E. coli was alive. After 5 days, in the same samples, the blue spots were seen to be larger and darker than before, while the plasma-treated powder showed no changes. The results from FE-SEM analysis showed that the E. coli was damaged and/or destroyed by reactive species generated in the plasma space, resulting in the E. coli being sterilized. Furthermore, the sterilization effects according to the selected parameters ($N_2$ and Ar; flow rate 30 and 50 sccm) adapted in this study were mutually similar, regardless of such different process parameters, and this indicates that homogeneous treatment of powder surfaces could be more effective than conventional methods. Therefore, the plasma apparatus used in this study may be a practical method to use in a powerful sterilization process in powder-type food.

급식소 식품접촉표면 위생 모니터링 도구로서의 ATP Luminometer 적합성 확인 (Verification of the Suitability of the ATP Luminometer as the Monitoring Tool for Surface Hygiene in Foodservices)

  • 김양숙;문혜경;강성일;남은정
    • 한국식품영양과학회지
    • /
    • 제39권11호
    • /
    • pp.1719-1723
    • /
    • 2010
  • 창원시 소재 단체급식소 4개소에서 사용하는 칼($12\;cm^2$), 도마($100\;cm^2$), 고무장갑(손바닥과 손가락 사이)의 표면을 대상으로 ATP Luminometer와 일반세균수용 건조필름을 이용한 미생물 배양법을 함께 적용하여 ATP(RLU)와 APC (CFU)을 측정하였다. 통계분석 결과, 3가지 조리도구 모두에서 ATP(RLU)와 APC(CFU) 간에 유의적인 양의 상관성이 존재하였다. 각 도구별 상관계수는 칼 0.84(p<0.001), 도마 0.79(p<0.001), 고무장갑 0.78(p<0.001)로 나타났다. 본 실은 단체급식 현장에 적합한 ATP Luminometer 가이드라인을 설정하기에 앞서 실시간적인 표면 위생 모니터링 도구로서의 사용 적합성을 살펴 본 예비실험이며, 도출된 회귀식을 이용하여 도구별 ATP(RLU) 가이드라인을 설정하고 검증할 예정이다.

한국에서 수집된 케퍼 그레인의 특성에 대한 연구 (Studies on the Characteristics of Kefir Grains Collected from Korean)

  • 박선정;주영철;장윤현;차성관
    • 한국축산식품학회지
    • /
    • 제23권3호
    • /
    • pp.262-268
    • /
    • 2003
  • Locals 케퍼 그레인은 코카서스 지방에서 유래한 전통적인 발효유이며, 주로 젖산균과 효모로 우유를 발효시켜서 만든다. 국내에서 수집한 10종류의 케퍼 그레인 중에서 6종류가 포도송이 형태나 융털, 나뭇잎, 좁쌀, 수건 같은 특징적인 형태를 가지고 있었으며, 젤라틴같이 끈적한 조직감을 나타냈다. 케퍼 그레인에서 우점하는 미생물을 조사하기 위하여 SPC, MRS, Ml7, Rogosa와 APT 한천배지와 petrifilm을 사용하여 일반세균과 효모를 계수하였다. 5종류의 한천배지 중에서 가장 검출률이 좋았던 것은 SPC, MRS와 Rogosa 한천배지였으며, Ml7과 APT 한천배지에서는 균락의 수가 매우 적었는데, 이는 케퍼 그레인에 존재하는 미생물의 종류가 대부분 젖산간균이었기 때문으로 추정되었다. 각 케퍼 그레인당 50여개 정도의 균락을 분리하여 API 50 CHL kit로 동정한 결과 Lactobacillus fermentum과 Lb. brevis가 각각 41∼88%와 2∼54%의 점유율을 나타내는 우점균으로 밝혀졌다. 이 외에 Lactococcus lactis subsp. lactis와 Leuconostoc mesenteroides subsp. mesenteroides가 소수로 검출되었으며, 일반세균은 전체적으로 $10^{8}$ cfu/g 수준이었고, 효모는 $10^{6}$$10^{7}$ cfu/g수준이었다. 케퍼 그레인의 효과적인 보존방법을 찾기 위하여 멸균된 10%환원탈지유와 혼합하여 동결건조한 것, 3개월간 냉장보존한 것, 그리고 6개월간 냉동보존한 것, 그리고 케퍼 그레인 자체로 냉동보존한 것을 비교 평가하였다. 그 결과, 냉동보존한 케퍼 그레인의 복원시 산 생성력이 우수하였으나 15개월 냉동건조한 케퍼 그레인이 냉장 또는 냉동보관한 케퍼 그레인에 비하여 산 생성력이 우수하였을 뿐만 아니라 이미와 이취도 거의 없어 가장 좋은 보존방법으로 평가되었다.