• Title/Summary/Keyword: Personal health device

Search Result 119, Processing Time 0.029 seconds

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

A Study on Analysis between Accidents Caused by Human Errors and Personal Characteristics of Railway Drivers (철도기관사들의 개인적 특성과 인적오류사고 발생에 대한 비교 분석)

  • Yum, Byeoung-Soo;Gal, Won-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.85-91
    • /
    • 2012
  • To verify the effect of driver's personal characteristics of driver on the accident frequency through railway accidents caused by human errors and the relationship with aptitude test. To prove the relevance between the driver's personal characteristics and human error accidents. Accident data from 2010 to 2011 was analyzed which collected from a train crew department in K national corporation, and 31 drivers gave an personal interview from Sep. 2011 to Nov. 2011 who had controlled a train alone and caused an accident. Compared between driver's personal characteristics and accident rate, and accident induction possibility surveyed from normal person and disqualified in aptitude tests. Accidents was occurred with the age 40s (27%) and 50s (25%), and with the experience between 15 years and 20 years (38%) and over 20 years (30%). Because more aged, more experienced, it can be seen in the correlation between driver's age and accidents induction caused by human errors like illusion. First of all it must be checked whether working conditions and environmental factors are human error-prone. Most accidents occur when received civil complaints or manager at the riding. Therefore accidents can be prevented when investigated through subsequent surveys how often human error happens, even though no accident, and safety device installed based on the error frequency.

A Novel Transmission Scheme for Compressed Health Data Using ISO/IEEE11073-20601

  • Kim, Sang-Kon;Kim, Tae-Kon;Lee, Hyungkeun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.5855-5877
    • /
    • 2017
  • In view of personal health and disease management based on cost effective healthcare services, there is a growing need for real-time monitoring services. The electrocardiogram (ECG) signal is one of the most important of health information and real-time monitoring of the ECG can provide an efficient way to cope with emergency situations, as well as assist in everyday health care. In this system, it is essential to continuously collect and transmit large amount of ECG data within a given time and provide maximum user convenience at the same time. When considering limited wireless capacity and unstable channel conditions, appropriate signal processing and transmission techniques such as compression are required. However, ISO/IEEE 11073 standards for interoperability between personal health devices cannot properly support compressed data transmission. Therefore, in the present study, the problems for handling compressed data are specified and new extended agent and manager are proposed to address the problems while maintaining compatibility with existing devices. Extended devices have two PM-stores enabling compression and a novel transmission scheme. A variety of compression techniques can be applied; in this paper, discrete cosine transformation (DCT) is used. And the priority of information after DCT compression enables new transmission techniques for performance improvement. The performance of the compressed signal and the original uncompressed signal transmitted over the noisy channel are compared in terms of percent root mean square difference (PRD) using our simulation results. Our transmission scheme shows a better performance and complies with 11073 standards.

Secure Communication Schemes over ISO/IEEE 11073-20601 for Smart Healthcare Service

  • Kim, Sang Kon;Kim, Tae Kon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2225-2238
    • /
    • 2022
  • For advanced healthcare services, a variety of agents should maintain reliable connections with the manager and communicate personal health and medical information. The ISO/IEEE 11073 standards provide convenient interoperability and the optimized exchange protocol (OEP) supports efficient communication for devices. However, the standard does not specify secure communication, and sensitive personal information is easily exposed through attacks. Malicious attacks may lead to the worst results owing to service errors, service suspension, and deliberate delays. All possible attacks on the communication are analyzed in detail, and the damage is specifically identified. In this study, novel secure communication schemes over the 20601 OEP are proposed by introducing an authentication process while maintaining compatibility with existing devices. The agent performs a secure association with the manager for mutual authentication. However, communication with mutual authentication is not completely free from attacks. Message encryption schemes are proposed for concrete security. The authentication process and secure communication schemes between the secure registered agent (SRA) and the secure registered manager (SRM) are implemented and verified. The experimental analysis shows that the complexities of the SRA and SRM are not significantly different from those of the existing agent and manager.

Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process (접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가)

  • Jaemin Woo;Dongjun Kim;Jihun Shin;Gihong Min;Chaekwan Lee;Wonho Yang
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.2
    • /
    • pp.78-88
    • /
    • 2023
  • Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

Design of a Personal-Led Health Data Management Framework Based on Distributed Ledger (분산 원장 기반의 개인 주도적 건강 데이터 관리 프레임워크 설계)

  • Moon, Junho;Kim, Dongsoo
    • The Journal of Society for e-Business Studies
    • /
    • v.24 no.3
    • /
    • pp.73-86
    • /
    • 2019
  • After the 4th industrial revolution, the healthcare industry is striving to find new business models through new technologies. Among them, blockchain technology is one of the technologies that have great interest in the healthcare industry. Most providers of personal health record systems have difficulty in securing marketability due to various problems. Therefore, they try to integrate blockchain technology to develop new systems and gain marketability. However, blockchain has limitations in solving the problems of the personal health record system. In this study, we have designed a personalized health data management framework that enables information subjects to acquire full ownership rights of individual's health data, based on distributed ledger technology. For the framework design, we refer to the structure of R3 Corda. It was designed with a different network structure than the existing blockchain systems so that the node can be operated on the personal user's mobile device. This allows information subjects to directly store and manage their own data and share data with authorized network members. Through the proposed system, the information utilization of the healthcare industry can be improved and the public health promotion and medical technology development can be realized.

Study on Building Smart Home Testbed for Collecting Daily Health Condition based on Internet of Things (사물인터넷 기반의 일상 건강정보 수집을 위한 스마트 홈 테스트베드 구축)

  • Chae, Myungsu;Kim, Yongrok;Kim, Sangsik;Kim, Sangtae;Jung, Sungkwan
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.5
    • /
    • pp.284-292
    • /
    • 2017
  • With the development of Internet of Things (IoT) technology, the combination of ICT and medical services has been increasing to improve the quality of medical services. Using the IoTs, we can collect personal health information continuously in a patient's everyday life. We expect that this will improve the quality of medical service through analysis. However, the problem of ensuring the protection of personal information within the personal health information has been hampering the research, development, and application of such services. Other problems include lack of IoT devices and lack of user convenience for collecting health information about a patient's everyday life. Therefore, in this study, we construct a daily health information management service that can collect the health related information at any time and store this data in personal storage. This data is then only provided to the healthcare worker when necessary. We built a test bed for an IoT-based smart home platform and are currently conducting user experiments. Based on the results of this study, we are attempting to provide a high quality medical trial service based on daily health information through linkage with medical device manufacturers, medical clinics, insurance companies, etc. We expect the proposed health information management service will contribute to the revitalization of smart health care services via activating various health related IoT devices and analyzing daily health information.

An Empirical Study on Acceptance Intention Towards Healthcare Wearable Device (기술 및 개인적 특성이 헬스케어 웨어러블 디바이스 수용의도에 미치는 영향에 관한 연구)

  • Lee, Sang-Il;Yoo, Wang-Jin;Park, Hyun-Sun;Kim, Sang-Hyun
    • The Journal of Information Systems
    • /
    • v.25 no.2
    • /
    • pp.27-50
    • /
    • 2016
  • Purpose The purpose of this study is to examine the effect of the acceptance intention towards healthcare wearable device in Korea. Specifically, this study attempted to identify the relationships among the acceptance intention towards healthcare wearable device, technical characteristics and user's personal characteristic based on UTAUT(Unified Theory of Acceptance and Use of Technology) model. Design/methodology/approach For this purpose of research, we conducted against consumers who use the wearable devices and we collected data from 219 wearable device users. The analyses were conducted using SPSS and AMOS19.0 which is powerful structural equation modeling (SEM) software. Findings The main findings are as followed; First, functional diversity, wearability, trend sensitivity and health perception are significantly related to performance expectancy, while visual aesthetic and enjoyment are not significantly related. Second, performance expectancy and effort expectancy are significantly related to acceptance intention towards healthcare wearable device. Third, effort expectancy is significantly related to performance expectancy.