• Title/Summary/Keyword: Personal Manufacturing

검색결과 237건 처리시간 0.03초

인조광물섬유 제품 제조 및 취급 근로자의 공기중 섬유 노출 평가 및 노동부 노출기준 고찰 (Workers' Exposure to Airborne Fibers in the Man-made Mineral Fibers Producing and Using Industries)

  • 신용철;이광용
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.221-231
    • /
    • 2005
  • In this study, occupational exposures to man-made mineral fibers (MMMFs) including glass wool, rock wool, and continuous glass filament fibers were determined and evaluated on the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV). A total of 171 personal samples collected from 4 glass wool fiber, 2 rock wool fibers, 4 continuous filament glass fiber products manufacturing and a glass fiber and rock wool insulations using industries, and determined respirable fibers concentrations using the National Institute for Occupational Safety and Health (NIOSH) Method 7400, "B counting rule. The fiber concentrations of samples from workers installing thermal insulations in a MMMF using industry showed the highest value: geometric mean (GM) = 0.73 f/cc and maximum = 2.9 f/cc, 70% of them were above the TLV, 1 f/cc. Workers' exposure level (GM= 0.032 f/cc) in the rock wool manufacturing industries was significantly higher than those of glass wool (GM=0.012 f/cc) and continuous filament glass fibers (GM=0.010 f/cc) manufacturing industries (p<0.01). No samples were more than the TLV in the MMMF manufacturing industries. There was a significant difference among companies in airborne fiber levels.

Study on Reusable Electrodes for Personal Electrocardiography

  • Kim, Jonghoon;Yoon, Gilwon
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.340-344
    • /
    • 2018
  • Electrodes are an important part of electrocardiography (ECG); disposable electrodes have been extensively used. However, personal ECG monitoring devices for Internet of Things applications require reusable electrodes. As there have been no systematic studies on the characteristics of reusable electrodes to date, we conducted this study to assess the performance and feasibility of electrodes with different materials. We built reusable electrodes using twelve different metallic materials, including commonly used copper, silver, zinc, plating materials, chemically inert titanium, stainless steel, and aluminum. Each electrode was fabricated to a size of $5{\times}10mm$. Their characteristics such as offset, baseline drift, stabilization time, and chemical inertness were compared. A personal ECG monitoring system was used to test the manufactured electrodes. The performances of the Ag, Cu, and Zn electrodes were better than the performances of other electrodes. However, these materials may not be used owing to the chemical changes that occur when the electrodes are in contact with the skin, such as discoloration and corrosion, which deteriorate their electrical characteristics. Titanium, stainless steel, and aluminum are chemically stable. The titanium electrode showed the best performance among the three, and it is our recommendation as a material for manufacturing reusable electrodes.

청력보존을 위한 예방 행위에 영향을 미치는 태도 분석 (A study on the attitude affecting the preventive behavior for hearing conservation)

  • 이경용;이관형
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권2호
    • /
    • pp.371-384
    • /
    • 1996
  • The purpose of this study is to investigate attitude factor related to hearing conservation and to find attitude affecting the preventive behavior for hearing conservation. The research method used in this study was self-administered questionnaire. Samples of the study were composed of 353 workers exposed noise selected randomly in 10 ship-building manufacturing companies. Authors extracted following 9 factors related hearing conservation from 26 attitude propositions prepared from previous study results and health belief model; (1) general perceived susceptibility, (2) relative perceived susceptibility compared with colleagues, (3) concern to the personal protective devices, (4) perceived severity and concern to the hearing capacity, (5) concern to the hearing and noise assessment, (6) concern to the control noise and hearing conservation, (7) group pressure and reason of wearing protective devices, (8) apathy of hearing loss from noise, (9) knowledge about hearing conservation. Attitude factors affecting the preventive health behavior were general perceived susceptibility, concern to the noise control and hearing conservation, and concern to the personal protective devices in the case of wearing personal protective devices. But in the case of avoiding noise exposure as preventive health behavior, perceived severity and concern to the hearing capacity was a significant attitude factor with knowledge about hearing conservation.

  • PDF

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.

자동생산을 위한 금형가공의 합리화 (Relationality of Metal Mould Manufacturing for the Automatic Production)

  • 현동훈;이용성
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2286-2293
    • /
    • 1993
  • The study presents the development of a cost-effective CAD/CAM system for metal moulds by use of personal computer. In the personal CAD/CAM system named DKSYS, metal moulds are defined by the operations of basic elements such as prism, pyramid and sphere, plane, rotational body, and surface elements including curved surface. The internal expression of shape elements in the computer is based on the wire model, which is a set of cross-sectional curves of the shape elements. With the addition of OMS system to CAD/CAM system the optimum cutting condition can be selected automatically. After programming NC information with the form definition and the optimum cutting condition, the metallic mould can be formed by transferring cutting information to CNC machine through DNC system. Using a computer for the above process, it is possible to increase the productivity and reduce the cost.

중국의 제조물책임 관련법규에서의 제조물결함에 관한 연구 (The Product Defectiveness to Products Liability Claims in China)

  • 이시환
    • 무역상무연구
    • /
    • 제34권
    • /
    • pp.3-26
    • /
    • 2007
  • Product liability law lies at the center of the modem world. This law concerns liability for damages arising from the commercial sale of a product that causes personal injury or property damage because it was defective or falsely represented. One engaged in the business of selling or otherwise distributing products who sells or distributes a defective product is subject to liability for harm to persons or property caused by the defect. In short, product defectiveness is the heart of products liability law. Regardless of the underlying cause of action, the plaintiff in nearly every products liability case must prove that the defendant's product contained an unnecessary hazard that caused the harm. The purpose of this paper is to clarify the meaning of the product defectiveness to products liability claims in China. In China, Product to include most movable personal property, but to exclude services. And a product is defective when, at the time of sale or distribution, it contains a manufacturing defect, is defective in design, or is defective because of inadequate instructions or warnings.

  • PDF

코크스 제조 및 사용 공정에서의 코크스오븐 배출물질 연구 (Study on the Coke Oven Emissions in Cokes Using and Manufacturing Workplaces)

  • 이종천;안규동;조광성;이병국
    • 한국산업보건학회지
    • /
    • 제11권2호
    • /
    • pp.145-152
    • /
    • 2001
  • This study was performed to evaluate the coke oven emissions (COE) and polynuclear aromatic hydrocarbon levels in coke manu-facturing industry, secondary lead smelting industry and glass bottle manufacturing industry. 1. There were no significant difference between the means of personal samples and area samples by the types of industry(p>0.05). The levels of airborne total particulates of the secondary lead smelting industry was the highest($2.30mg/m^3$), and those of the coke manu-facturing industry and glass bottle manu facturing industry were $1.95mg/m^3$ and $1.37mg/m^3$. The concentration of COE was the highest in the glass bottle manufacturing industry($0.79mg/m^3$), and in order of $0.19mg/m^3$ in the coke manufacturing industry and $0.06mg/m^3$ in the secondary lead smelting industry. COE/total particulates(%) was highest in the glass bottle manufacturing industry(58.1%) and in order of 10.3% in the coke manufacturing industry and 3.1% in secondary lead smelting industry. There were significant differences in the total particle concentration and COE by the types of industry(p<0.05). 2. The levels of airborne total particulates was the highest at the smelting process of secondary lead smelting industry($2.30{\pm}0.72mg/m^3$), and the lowest at the smelting process of glass bottle manufacturing industry ($0.99{\pm}1.22mg/m^3$) Concentration of COE was the highest at the casting process of glass bottle manufacturing industry ($1.09{\pm}1.15mg/m^3$), the lowest at the smelting process of secondary lead smelting industry ($0.06{\pm}0.03mg/m^3$). The COE/total particulates(%) was the highest at the casting process of glass bottle manufacturing industry($65.9{\pm}20.5%$), and the lowest at the smelting process of secondary lead smelting indusry($3.1{\pm}2.7%$). 3. There were positive correlations between level of The airborne total particulates and concentration of COE in coke manufacturing industry and glass bottle manufacturing industry (p<0.05), but negative correlation in secondary lead smelting industry. 4. The numbers of case and rates that over the Threshold Limit Values(TLVs) were 24 (77.4%)cases in glass bottle manufacture, 14(23.7%) cases in the coke manufacturing industry and no one case in secondary lead smelting industry. Total numbers of case and rates that over TLVs were 38( 35.5%) cases. 5. The limit of detection(LOD) for PAH was $10{\mu}g/ml$ in standard sample. All PAH levels of the cokes manufacturing industry and the secondary lead smelting industry and the glass bottle manufacturing industry were trace or not to detect.

  • PDF

휴게공간에서의 식물 도입이 생산직 근로자의 피로 회복에 미치는 효과 (Impact of Indoor Green in Rest Space on Fatigue Recovery Among Manufacturing Workers)

  • 윤초혜;정이봄;강민지;이주영
    • 한국환경과학회지
    • /
    • 제33권3호
    • /
    • pp.217-226
    • /
    • 2024
  • Manufacturing workers face increased fatigue and stress due to environmental factors in workplace such as noise and vibration. Addressing this issue requires creating conducive rest spaces; however, the existing conditions of rest spaces in manufacturing workplace are subpar and lack sufficient scholarly evidence. This study investigated the effect of nature-based rest spaces on the physical and emotional recovery from fatigue on manufacturing workers. Three manufacturing complexes with nature-friendly rest spaces were selected, and 63 manufacturing workers participated in the study. The measurement tools included the Multidimensional Fatigue Scale (MFS) for fatigue levels, physiological indicators (blood pressure and heart rate), and emotional indicators (Zuckerman Inventory of Personal Reaction Scale; ZIPERS, Perceived Restorativeness Scale; PRS, Profile of Mood States; POMS and State-Trait Anxiety Inventory; STAI). The study compared recovery levels during a 7-minute rest between a space without plants and a space with natural elements. The results indicated a significant reduction in systolic and diastolic blood pressure of participants in green rest spaces compared with those in conventional rest spaces. Regarding fatigue levels, green rest spaces showed a decrease in systolic blood pressure in the middle-fatigue and high-fatigue groups. Positive feelings increased in green spaces, whereas negative emotions decreased, suggesting that short breaks in nature-friendly environments effectively promote workers' physical and emotional recovery. Furthermore, this study emphasizes the importance of green space in various work environments to promote well-being in workers.

붐의 유연성을 고려한 트럭크레인의 설계 전용 동력학 해석 프로그램 개발 (Development of Truck Crane Analysis Program with Boom Flexibility)

  • 박찬종
    • 한국생산제조학회지
    • /
    • 제7권6호
    • /
    • pp.28-35
    • /
    • 1998
  • Computer simulation technique has been applied on the various engineering fields to reduce cost and development period. On this paper, we introduce a crane analysis program. Using this program, we can predict reaction force of each part or supporting force of truck crane on a personal computer system with out exclusive knowledge of multi-body dynamics. In order to consider the effect of boom flexibility according to each working condition, flexible dynamic theory is applied to the program. Actual crane model is analyzed on special work condition using this program and the results are compared with those of rigid boom model.

  • PDF

팬의 위치에 따른 컴퓨터 본체 내부의 공기유동에 관한 시뮬레이션 해석 (Simulation Analysis on the Air Flow Inside Computer Main Frame According to the Location of Fan)

  • 조재웅;한문식
    • 한국생산제조학회지
    • /
    • 제21권2호
    • /
    • pp.259-266
    • /
    • 2012
  • In this study, the temperature distributions are analyzed on the air flow according to the position of fan inside computer main frame by CFD simulation. In case that ventilation hole is existed at the side of computer frame, the air with lower temperature can be circulated near CPU radiant thermal panel. In case of installation with fan at the side panel, the temperature of air flow becomes lowest. The efficiency of thermal emission at personal computer and its durability can be improved by releasing a lot of heat at air flow effectively inside computer frame according to this simulation result.