• Title/Summary/Keyword: Personal Device

Search Result 767, Processing Time 0.026 seconds

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.

The control & measurement of DC/STEP motor device using the computer (PC를 이용한 직류/스탭모터 장치의 제어.계측)

  • Son, Jun-Hyug;Seo, Bo-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2206-2208
    • /
    • 2002
  • In this paper, using the communication port between PC(Personal Computer) and DC/STEP MOTOR DEVICE that movement and measurement of motor. Communication port used serial port and movement order transmits by communication port. Consequence of motor device movement displays to tile DC/STEP MOTOR DEVICE APPLICATION. This connection is using the serial port instead of parallel port faster than response time And this application is easier than existing application.

  • PDF

Design of Open Gateway Framework for Personalized Healing Data Access (개인화된 힐링 데이터 접근을 위한 개방형 게이트웨이 프레임워크 설계)

  • Jeon, YoungJun;Im, SeokJin;Hwang, HeeJoung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.1
    • /
    • pp.229-235
    • /
    • 2015
  • ICT healing platform is based on bio-signal and life habit information target to alarm early sickness concept prevention chronic pain. ICT(Information & Communication Technology) healing platform target on personal lead health management care of several health agencies and open of the (hospital, fitness center, health examination center, personal health device) personal health information together to personal device. Support Analysis Platform and Open API to vitalization optional services. In this paper proposal to access personality healing data Open Gateway Framework of Healing Platform Adaptor (HPAdaptor) ICT healing platform means Data relaying link to EMR(Electronic health record), korean medicine, life log, wellness, chronic pain, and fineness several personal health data provider and service provider personal healing data with software engine. After Design HPAdaptor can use for data and service provider record storage, mobile platform and analytics platform need data service or platform relying reference model.

Development of Reliability Demonstration Test for Personal Blood Glucose Meters (개인용 혈당측정기의 신뢰성 보증시험 개발)

  • Kim, Gi-Young;Park, Ho-Joon;Park, Chan-Soo;Ham, Jung-Keol;Jang, Joong Soon
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.299-307
    • /
    • 2013
  • The value of blood sugar is measured by a personal blood glucose meter which consists of two parts: a glucose strip and a blood glucose meter. A personal blood glucose meter makes use of electric media which are composed of glucose oxidase and electron. This study is to propose a method of reliability demonstration test derived from field data analysis and FMEA(Failure Mode and Effect Analysis). Detailed Conditions for reliability demonstration test are selected from the comparison of various failure mechanisms. The most dominant failure mechanism is wear-out which is caused by strip insertion/extraction. The testing device that can reproduce the failure mechanism of strip insertion/extraction is made to conduct reliability demonstration test. Using the testing device, it is confirmed that target lifetime of selected devices is more than 2 years.

Analysis of Low Power and Channel Interferences for Zigbee (Zigbee의 저전력화와 채널간섭 분석)

  • Kang, Min-Goo;Shin, Ho-Jin
    • Journal of Internet Computing and Services
    • /
    • v.11 no.3
    • /
    • pp.33-41
    • /
    • 2010
  • The battery consumption and the wireless communication pattern were analyzed for the low power and the improvement of channel interferences between of Zigbee networks and WPAN(Wireless Personal Area Network). The communication patterns considering end device's battery saving during channel searching period were analyzed for low power consumption topology of Zigbee dynamic ad-hoc characteristics. And, the communication patterns were analyzed due to channel interferences between WLAN and Random Back off of Zigbee, too. As a result, the communication patterns of Zigbee's coordinator and end devices is alleviated for the longer battery life time of Zigbee's end device due to Zigbee's end device setting techniques.

STEPSTONE: An Intelligent Integration Architecture for Personal Tele-Health

  • Helal, Sumi;Bose, Raja;Chen, Chao;Smith, Andy;De Deugd, Scott;Cook, Diane
    • Journal of Computing Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.269-281
    • /
    • 2011
  • STEPSTONE is a joint industry-university project to create open source technology that would enable the scalable, "friction-free" integration of device-based healthcare solutions into enterprise systems using a Service Oriented Architecture (SOA). Specifically, STEPSTONE defines a first proposal to a Service Oriented Device Architecture (SODA) framework, and provides for initial reference implementations. STEPSTONE also intends to encourage a broad community effort to further develop the framework and its implementations. In this paper, we present SODA, along with two implementation proposals of SODA's device integration. We demonstrate the ease by which SODA was used to develop an end-to-end personal healthcare monitoring system. We also demonstrate the ease by which the STEPSTONE system was extended by other participants - Washington State University - to include additional devices and end user interfaces. We show clearly how SODA and therefore SODA devices make integration almost automatic, replicable, and scalable. This allows telehealth system developers to focus their energy and attention on the system functionality and other important issues, such as usability, privacy, persuasion and outcome assessment studies.

An User Experience of Proactive Intelligent Personal Assistant: Focusing on Google 'Nest Hub Max' (능동적 지능형 가상 비서의 사용자 경험 연구 : Google의 'Nest Hub Max'를 중심으로)

  • Cho, Soo Kyung;Kim, Jae-Yeop
    • Journal of Digital Convergence
    • /
    • v.18 no.9
    • /
    • pp.379-389
    • /
    • 2020
  • This is a qualitative study about Google 'Nest Hub Max' that displays proactive intelligent personal assistant. Following the step of grounded theory, an in-depth interview for 6 users who had used this device for a month was taken. 186 concepts were discovered, categorized as 11 top-categories and 24 sub-categories. Paradigm diagram, considering axis-coding, was made and it have been narrowed down to 'Usage patterns' of proactive IPA, considering selective coding aspects. 'Usage patterns' were divided to passive and active user. Thus, neither passive user nor active user was satisfied about device and proactive IPA. This study is meaningful that it constructed basic data about the user experience of proactive IPA on this device. It will support the device or service that consists proactive IPA in the future.

The Status of the Bring Your Own Device (BYOD) in Saudi Arabia: Dataset

  • Khalid A. Almarhabi;Adel A. Bahaddad;Ahmed M. Alghamdi
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.2
    • /
    • pp.203-209
    • /
    • 2023
  • The paper brings across data that is utilized in the Bring Your Own Device (BYOD) status collected between February and April of 2021 across Saudi Arabia. The data set was collected using questionnaires established through online mechanisms for the respondents. In the questionnaire, personal details included five questions while seven questions addressed the working model of personal mobile devices. Six questions addressed the awareness of employees bring your own device awareness for employees comprised seven questions and two questions addressed the benefits of business achievements. In the identification of suitable respondents for the research, two approaches were applied. The research demanded that the respondents be Saudi Arabian nationals and have attained 18 years. Snowball and purposive techniques were applied in the collection of information from a wide area of Saudi Arabia while employing social media approaches that include the use of WhatsApp and emails in the collection of data. The approach ensured the collection of data from 857 respondents used in the identification of the status as well as issues across the BYOD environment and accompanying solutions. The data was also used in the provision of awareness in the community through short-term courses, cyber security training and awareness programs. The results of the research are therefore applicable to the context of the Saudi Arabian country that is currently facing issues in dealing with the application of personal devices in the work environment.

Development of Vehicle Status Alerts System for Personal Information Leakage Protection using the NFC-based GCM Service (개인정보 유출 방지를 위한 NFC 기반 GCM 서비스를 이용한 차량 상황 알림 시스템 개발)

  • Kang, Hyun-Min;Choi, Hyun-Su;Cha, Kyung-Ae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.317-324
    • /
    • 2016
  • This paper proposes a message transfer application using smartphone with NFC(Near Field Communication) and GCM(Goolge Cloud Messaging) technology for prevention of personal information leakage. In implementing for the proposed system, we design a NFC-based vehicle status alerts service which make it possible to communicate with smartpone message without phone-number between a car driver and an unspecified person. The application provides message communication mechanism without exposing the real phone number, using the NFC tag written with the driver's smartphone device ID and GCM push messages. Through the evaluation result of the actual implemented application, the proposed system can be efficient technology in protection for leakage of personal information such as personal phone- number in daily life.