• 제목/요약/키워드: Permeate

검색결과 518건 처리시간 0.032초

Water desalination by membrane distillation using PVDF-HFP hollow fiber membranes

  • Garcia-Payo, M.C.;Essalhi, M.;Khayet, M.;Garcia-Fernandez, L.;Charfi, K.;Arafat, H.
    • Membrane and Water Treatment
    • /
    • 제1권3호
    • /
    • pp.215-230
    • /
    • 2010
  • Poly(vinylidene fluoride-co-hexafluoropropylene), PVDF-HFP, hollow fiber membranes were prepared by the dry/wet spinning technique using different polyethylene glycol (PEG) concentrations as non-solvent additive in the dope solution. Two different PEG concentrations (3 and 5 wt.%). The morphology and structural characteristics of the hollow fiber membranes were studied by means of optical microscopy, scanning electron microscopy, atomic force microscopy (AFM) and void volume fraction. The experimental permeate flux and the salt (NaCl) rejection factor were determined using direct contact membrane distillation (DCMD) process. An increase of the PEG content in the spinning solution resulted in a faster coagulation of the PVDF-HFP copolymer and a transition of the cross-section internal layer structure from a sponge-type structure to a finger-type structure. Pore size, nodule size and roughness parameters of both the internal and external hollow fiber surfaces were determined by AFM. It was observed that both the pore size and roughness of the internal surface of the hollow fibers enhanced with increasing the PEG concentration, whereas no change was observed at the outer surface. The void volume fraction increased with the increase of the PEG content in the spinning solution resulting in a higher DCMD flux and a smaller salt rejection factor.

실리카겔을 이용한 흡착식 담수화 시스템 개발 (Development of Adsorption Desalination System Utilizing Silica-gel)

  • 현준호;;이윤준;천원기
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.364-369
    • /
    • 2012
  • The development of solar thermal energy used adsorption desalination technology have been examined as a viable option for supplying clean energy. In this study, the modelling of the main devices for solar thermal energy used and adsorption desalination system was introduced. Silica gel type adsorption desalination system is considered to be a promising low-temperature heat utilization system. The design is divided into three parts. First, the evaporator for the vaporization of the tap water is designed, and then the reactor for the adsorption and release of the steam is designed, followed by the condenser for the condensation of the fresh water is designed. In addition, new features based on the energy balance are also included to design absorption desalination system. In this basic research, One-bed(reactor) adsorption desalination plant that employ a low-temperature solar thermal energy was proposed and experimentally studied. The specific water yield is measured experimentally with respect to the time controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times. Desalination is processes that permeate our daily lives, but It requires substantial energy input, powered either from electricity or from thermal input. From the environmental and sustainability perspecives, innovative thermodynamic cycles are needed to produce the above-mentioned useful effects at a lower specific energy input. This article describes the development of adsorption cycles for the production of desalting effects. We want that this adsorption system can be driven by low temperature heat sources at 60 to $80^{\circ}C$, such as renewable, solar thermal energy.

  • PDF

나권형 역삼투 모듈에 의한 Cephalosporin C의 농축분리에 관한 실험연구 (Experimental Study on Separation of Cephalosprotin C by Spiral-Wound Reverse Osmosis Module)

  • 신동엽;류정;이용철
    • 공업화학
    • /
    • 제10권4호
    • /
    • pp.563-567
    • /
    • 1999
  • 용질배제율이 우수한 나권형 FT-30 폴리아미드 복합막을 상용하여 cephalosporin C를 농축하기 역삼투 농축실험을 하였다. $4{\sim}20kg/cm^2$의 압력과 100~1000 mg/L의 농도, 그리고 2.8과 5.6 L/min의 유속을 갖는 실험 조건하에서 cephalosporin C 수용액의 수투과율과 용질의 배제율 및 물질전달 계수를 구하였다. Cephalosporin C를 분리하는데 있어서 압력이 증가함에 따라 투과 플럭스가 증가하는 것으로 나타났다. 이 결과는 Kedem-Katchalsky 모델에서 예측한 것과 일치하였다. 그리고 배제율은 1에 가까웠다. 또한 공급액의 농도가 증가할수록 cephalosporin C의 배제율은 낮아지는 것으로 나타났다. 배제율은 고농도보다는 저온도에서 높게 나타났으나 그 감소 정도는 작았다.

  • PDF

에탄올 수용액의 Pervaporation에서의 투과거동 (A Permeation Behavior for the Pervaporation of Aqueous Ethanol Solution)

  • 배성렬;이한선;황성민;김희택;히데히로 구마자와
    • 공업화학
    • /
    • 제5권1호
    • /
    • pp.127-138
    • /
    • 1994
  • CTA(cellulose triacetate) 막을 이용한 물과 에탄올의 투과증발(pervaporation) 막분리에서 수착과 투과실험으로부터 용해-확산 투과기구modeling 및 그 함수형과 parameters에 대한 해석을 시도하였다. 순성분들의 수착 data를 사용하여 Flory-Huggins 식으로 계산한 3 성분계(에탄올/물/CTA) 수착평형 조성을 추산하여 실측치와 비교하였다. 막 내부의 조성과 액상의 평형 조성간에 열역학적 평형 관계식을 적용하기 위해 막 내 겉보기 활동도를 Wilson식과 Van Laar식으로 상관시켰다. 투과속도식은 한 성분의 투과속도가 그 성분의 막 내 농도구배에 비례하며, 또한 확산계수의 농도 의존성이 에탄올 농도만의 지수함수라고 가정하여 물과 에탄을 투과속도를 계산하였으며 이는 실측치와 잘 일치하였다. 한 성분의 투과속도와 수착량이 다른 성분에 비해 현저히 작은 경우에는 대류항을 무시할 수 없음을 알았고, 온도가 높고, 투과측 압력이 낮을수록 투과속도와 투과선택도가 증가하였다.

  • PDF

복류수를 이용한 한외여과공정의 장기운전 평가 (Long Term Evaluation of UF Membrane process using River-bed Water)

  • 김충환;임재림;강석형;김수한
    • 상하수도학회지
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2008
  • Membrane system has been increasingly considered as a safe and cost-effective water treatment process especially in case of small scale water works. This research is a basis of membrane application in water works through a long period test with obtaining operation skills and evaluation of water quality and cost competitiveness. For the research, the UF membrane system was installed in small water treatment plant that uses river-bed water as raw water. The system was consisted of 2 stage membrane and operated in constant flow mode (Flux: 1.5, 1.0, 0.9, 0.6). In each different flux condition, TMP trends were showed better results at lower flux condition. And through the high flux condition test, it is certified that membrane system could deal with breakdown of one stage. Water quality of permeate was satisfied the water quality standards especially turbidity. To know what mainly causes fouling on membrane, the test by membrane with several cleaning agents and EDX analysis have done in lab. Through the tests, ferrous concentration in raw water, backwashing water and membrane surface etc. was high and it causes fouling inside and outside of membrane. So acid cleaning using organic acid such as oxalic acid is necessary in Chemical in Place (CIP). At the economical aspect the electrical cost of membrane system is higher than that of slow sand filtration but labor cost can be reduced by automation. However, the use of labor should be determined considering effectiveness and stability of operation. Because during the operation, there are several breakdown such as electrical shock by lightning, water drop in summer, etc.

제주도 삼양 수원지 RO 시설 도입 연구 (A Study on the Introduction of RO Facility for Jeju Samyang Water Source)

  • 김우찬;김진근
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.601-608
    • /
    • 2015
  • Pollutants removal efficiency in pretreatment(GAC filter, multi-media filter, disk filter) and RO facilities was investigated for the Jeju Samyang spring water source where raw water intake has been stopped due to sea water intrusion. In addition, preliminary feasibility analysis was conducted between RO and groundwater intake systems. Turbidity removal in 4 different pretreatment processes was less than 25% due to low concentration of turbidity(i.e., less than 0.21 NTU), while multi-media filter is recommended for the pretreatment facility based on the low organic content in raw water as well as cheaper operation and maintenance cost. The average concentration of $Cl^-$ in raw water was 691.4 mg/L, while that of RO permeate was 9.1 mg/L(i.e., removal efficiency was 98.4%). In addition, TDS removal efficiency was 98.1%, which was quite high. The production cost for RO system($Q=4,000m^3/d$) was $362.1won/m^3$ considering installation, operation and maintenance cost for 30 years. While that of groundwater was $262.6won/m^3$ which was low compared to the RO system. However, it is recommended to introduce RO system for Samyang water source rather than new groundwater development because Samyang water source has been discharged to the sea without any usage, while groundwater can be used for other purpose as a sustainable water source.

노트북용 액정 모듈 내부의 온도 및 상대 습도 변화에 관한 실험적 연구 (Experimental Study of Internal Distribution of Temperature and Relative Humidity in Notebook LCD Module)

  • 김태우;김기빈;이재원
    • 대한기계학회논문집A
    • /
    • 제36권2호
    • /
    • pp.217-221
    • /
    • 2012
  • 노트북용 액정 모듈 내부의 광학 시트(Optical Sheet) 변형에 기인한 시인성 품질 불량을 개선하기 위한 기초 연구의 일환으로 변형 유발의 요인인 온도 및 습도의 영향을 분석할 수 있는 측정 시스템이 필요하였다. 액정 모듈 내부에는 0.5mm 미만의 미세한 공기 층이 존재하는데, 이 공간으로 외부의 습한 공기가 내부로 확산되는 것으로 추정된다. 이러한 현상을 규명하기 위하여 초소형 온도 및 습도 센서를 실장한 초박형 센서 PCB 를 액정 모듈 내부에 삽입하여 실시간으로 온/습도 변화를 측정 및 분석하였으며, 향후 변형 거동 시뮬레이션 및 구조 설계 시 필요한 기초 데이터로 활용하고자 한다.

Improvement of ${\beta}-glucosidase$ Activity of Olea europaea Fruit Extracts Processed by Membrane Technology

  • Mazzei, R.;Giomo, L.;Spadafora, A.;Mazzuca, S.;Drioli, E.
    • Korean Membrane Journal
    • /
    • 제8권1호
    • /
    • pp.58-66
    • /
    • 2006
  • The ${\beta}-glucosidase$ from olive fruit is of particular interest compared to the ones from other sources because it has shown to have high specifity to convert the oleuropein into dialdehydes, which have antibacterial activity and are of high interest for their application in the food and pharmaceutical fields. The enzyme is not yet commercially available and advanced clean and safe technologies for its purification able to maintain the functional stability are foreseen. The purification of this protein from fruit extracts has been already tempted by electrophoresis but either enzyme deactivation or high background with unclear profiles occurred. In this work, fruit extracts obtained from the ripening stage that showed the highest enzyme activity have been processed by diafiltration and ultrafiltration. Asymmetric membranes made of polyamide or polysulphone having 50 and 30 kDa molecular weight cut-off, respectively, were tested for the diafiltration process. Ultrafiltration membranes made of polyethersulfone with 4 kDa molecular weight cut-off were used to concentrate the dia-filtered permeate solutions. The efficiency of the separation processes was evaluated byenzyme activity tests using the hydrolysis of p-D-nitrophenyl-${\beta}$-D-glucopyranoside (pNPGlc) as reaction model. Qualitative and quantitative electrophoresis were applied to analyze the composition of protein solution before and after the membrane separation; in addition dot blot and western blot analyses were applied to verify the presence of ${\beta}-glucosidase$ in the processed fractions. The overall results showed that the ${\beta}-glucosidase$ functional stability was preserved during the membrane operations and the removal of 20 kDa proteins allowed to increase the specific activity of the enzyme of about 52% compared to the one present in the initial fruit extract.

에너지 소모를 고려한 역삼투 해수담수화 플랜트 주요 성능인자 영향 분석 (Comprehensive Analysis of Major Factors Associated with the Performance of Reverse Osmosis Desalination Plant for Energy-saving)

  • 김지혜;이경혁;임재림
    • 멤브레인
    • /
    • 제29권6호
    • /
    • pp.314-322
    • /
    • 2019
  • 기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 ㎥/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/㎥로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/㎥ 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/㎥, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.

2단 가수분해에 의한 굴 가수분해물의 기능성 개선 (Improving the Functional Properties of Oyster Hydrolysates by Two-step Enzymatic Hydrolysis)

  • 정인권;김진수;허민수
    • 한국수산과학회지
    • /
    • 제39권3호
    • /
    • pp.269-277
    • /
    • 2006
  • This study prepared functional oyster hydrolysates using two-step enzymatic hydrolysis and investigated their functional properties. To prepare two-step enzymatic hydrolysates (TSEH), oysters were hydrolyzed using 1% Protamex (PR) at $40^{\circ}C$ and pH 6.0 for 1 hr before sequential treatment with one of the following enzymes for 1 hr: Alcalase (AL), Flavourzyme (FL), Neutrase (NE), pepsin (PE), and trypsin (TR). The PRAL, PRNE and PRTR hydrolysates had significantly greater angiotensin I converting enzyme (ACE) inhibitory activity than did PR and the other TSEHs. Only the antioxidant activity of the PRNE hydrolysate was significantly different (p<0.05), while none of the TSEHs had antimicrobial activity. The oyster hydrolysate prepared by sequential treatment with Protamex and Neutrase (PRNE) had the best ACE inhibitory activity and antioxidant activity, with $IC_{50}$ values of 0.40 and 0.94 mg/mL, respectively. The PRNE hydrolysate was processed through an ultrafiltration (UF) series with molecular weight cut-off (MWCO) membranes of 3, 5, 10, and 30 kDa, and the ACE inhibitory, antioxidant, and antimicrobial activities of the permeates were determined. The permeate through the 3-kDa MWCO membrane had greater ACE inhibitory activity and antioxidant activity than did the other PRNE permeates, with $IC_{50}$ values of 0.11 and 0.40 mg/mL, respectively.