• Title/Summary/Keyword: Permeance

Search Result 229, Processing Time 0.026 seconds

Analysis and Design of Permanent Magnet Motor by the Improved Permeance Method (개선된 퍼미언스법에 의한 영구자석 회전기의 해석 및 설계)

  • Chung, Tae-Kyung;Oh, Seung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.175-178
    • /
    • 1998
  • To analyze and design a motor magnetic permeance method and numerical methods such as F.E.M. are used. In this thesis, DC motor is analyzed and designed by the permeance method. Modified Carter coefficient and leakage permeance are presented. A magnetic flux path can be approximated properly by using a equivalent ${\pi}$ network representation adding the leakage coefficient. Finally, effective and easy-to-use program is realized. Experimental analysis and design with an actual motor proves that this program produces reliable results. There are many experimental coefficients in this algorithm and it makes some design errors. Using of this program, an motor engineer can obtain satisfactory characteristic and design value by inputting initial data at once.

  • PDF

Performance Analysis of Water Gas Shift Reaction in a Membrane Reactor (막반응기에서의 수성가스전이반응의 성능 분석)

  • Lim, Hankwon
    • Applied Chemistry for Engineering
    • /
    • v.25 no.2
    • /
    • pp.204-208
    • /
    • 2014
  • This study investigated the effect of hydrogen permeance and selectivity, catalyst amount, $H_2O/CO$ ratio in a feed stream, and Ar sweep gas on the performance of a water gas shift reaction in a membrane reactor. It was observed that a minimum hydrogen selectivity of 100 was needed in a membrane reactor to obtain a hydrogen yield higher than the one at equilibrium and the hydrogen yield enhancement gradually decreased as the hydrogen permeance increased. The CO conversion in a membrane reactor initially increased with the catalyst amount and reached a plateau later for a membrane reactor with a low hydrogen permeance while the high CO conversion independent of a catalyst amount was observed for a membrane reactor with a high hydrogen permeance. For the $H_2O/CO$ ratio in a feed stream higher than 1.5, a hydrogen permeance had little effect on the CO conversion in a membrane reactor and it was found that a minimum Ar molar flow rate of $6.7{\times}10^{-6}mol\;s^{-1}$ was needed to achieve the CO conversion higher than the one at equilibrium in a membrane reactor.

A Type of Subsection Model for a Permanent Magnet Bar and its Leakage Permeance Calculation Method in an Open Magnetic Circuit

  • Liang, Huimin;You, Jiaxin;Yang, Wenying;Zhai, Guofu
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • The equivalent model of a permanent magnet (PM) plays an important role in electromagnetic system calculation. A type of subsection model for a PM bar is established, to improve the accuracy of the traditional equivalent circuit method. The mathematical expression, and its end verification condition, are presented. Based on the analytical method and finite element method, the leakage permeance calculation of a PM bar in an open magnetic circuit is investigated. As an example, for a given certain type of PM bar, the magnetic flux of each section is validated by experiment, and by simulation. This model offers a foundation for building a high accuracy equivalent magnetic PM model in an electromagnetic system.

Hypochlorite treatment of polyamide membrane for improved reverse osmosis performance

  • Shao, P.;Kurth, C.J.
    • Membrane and Water Treatment
    • /
    • v.4 no.1
    • /
    • pp.69-81
    • /
    • 2013
  • The pH-dependent inter-conversion of the three free chlorine species ($Cl_2$, HOCl, OCl-) present in the aqueous hypochlorite solution was theoretically investigated. Each species was found overwhelmingly present in a characteristic pH range. Hypochlorite treatment of the polyamide membrane was carried out over these pH ranges and various membrane responses were observed. As pH is less than 8, membrane tends to be N-chlorinated by $Cl_2$ and HOCl, and N-chlorinated membrane showed reduced water permeance and salt rejection. As pH rises to 10-12, $OCl^-$ appears to be the dominating chlorine species. Membrane hydrolysis was found to well interpret the improved water permeance and salt rejection. When the pH is between 8-10, both N-chlorination and hydrolysis contribute to the response of the membrane, and the treated membrane showed improved salt rejection but reduced water permeation. Excessive hydrolysis occurred while the membrane was treated at pH 13 for the much stronger alkalinity.

Hydrogen Permeance of Silica Membrane Prepared by Chemical Vapor Deposition Method on an $\alpha$-Alumina Support Tube (기상 화학증착법에 의해 $\alpha$-Alumina 지지관 상에 제조한 Silica막의 수소투과 특성)

  • 김성수;이재홍;서동수;박상욱;서봉국
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.669-677
    • /
    • 1998
  • A porous $\alpha$-alumina tube of 2.5 mm O.D. and 1.9 mm I.D. was used as the support of an inorganic membrane. Macropores of the tube, about 150 nm in size, were plugged with silica formed by thermal decomposition of tetraethylorthosilicate at $600^{\circ}C$. The forced cross-flow CVD method that reactant was evacuated through the porous wall of the support was very effective in plugging macropores. The H$_2$ permeance of the prepared membrane was of the order of $10^{-8}/ molㆍs^{-1}/ㆍm^{-2}/. Pa{-1}$/, while the $N_2$ permeance was below $10^{-11}/ molㆍs^{-1}/ㆍm^{-2}/ㆍPa^{-1}$/ at $600^{\circ}C$. This was comparable to that of silica-modified Vycor glass whose size was 4 nm.

  • PDF

Position Accuracy Error Analysis in 2 Phase 8 Pole HB Type LPM (2상 8극 HB형 LPM의 위치오차 해석)

  • Kim, Sung-Hun;Lee, Eun-Woong;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.38-41
    • /
    • 1997
  • As the LPM is used for position accuracy decision device it is required that both the reason of posion error and the definition of position itself should be cleared. In this study, the precision of the position decision of LPM is affected by the geometrical shape such as tooth shape or processing accuracy. By using the analysis of magnetic circuit, we calculated the permeance come up with the gap. Once the thrust force has been obtained, the permeance due to the mechanical error of the pole pitch and the tooth pitch becomes the error of thrust force. We confirmed as well that it is being affected by the difference due to the variation of the airgap permeance.

  • PDF

Design and Analysis of Permanent Magnet Type LDM for Implementation (계기용 영구자석형 LDM의 설계제작 및 기본특성 연구)

  • Kim, Yong;Baek, Soo-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.56-62
    • /
    • 1999
  • This paper is concerned with the design and the construction of a moving magnet type linear DC motor(MM type LDM) for instrumentation. A mathematical model for the design of a LDM is developed and a permeance method is used to calculate the effective flux density in the air gap. The flux distribution in the air gap is analyzed and the width of iron core should be determined in order not to saturate the iron core by caluclating maxmum flux density. The design data culculated by a permeance method are compared with the analyzed results using FEM(MAXWELL 2D). The errors between two results are corrected. The tested LDM is constructed using the corrected design data. The results of experiment for thrust characteristics are compared with simulation.

  • PDF

Calculation of Unbalanced Magnetic Pull of Induction Motors due to Rotor Misalignment (경사 편심에 의한 유도전동기의 자기흡인력 평가)

  • Kim, S.H.;Yang, B.S.;Kim, H.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1321-1327
    • /
    • 2006
  • This paper presents the calculation of unbalanced magnetic pull (UMP) that causes rotor misalignment in induction motor. The excessive noise and vibration will be occurred by means of rotor misalignment. Angular misalignment of rotor will produce air-gap permeance wave which is function of axial and circumferential coordinate. In this paper, the UMP is calculated using permeance and magneto motive force (MMF) in the case of static and dynamic misalignment. Based on the percentage of misalignment, the result shows that the UMP and magnetic pressure are increased according to the increasing of misalignment. The UMP is occurred not only in It frequency component but also the others.

  • PDF

Inductance Calculation in a Switched Reluctance Motor using Permeance Method (퍼미언스 방법을 이용한 스위치드 릴럭턴스 전동기의 인덕턴스 산정)

  • Lee, Cheewoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1836-1842
    • /
    • 2012
  • Torque is proportional to the rate of change of inductance in a switched reluctance motor (SRM), and hence, phase inductance is an important parameter in determining the behavior of an SRM. Therefore, the accurate prediction of inductance with respect to rotor position makes a significant contribution to designing an SRM and its analytical approach is not straightforward due to nonlinear flux distribution. Although several different approaches using a finite element analysis (FEA) or curve-fitting tool have been employed to compute phase inductance [2-5], they are not suitable for a simple design procedure because the FEA necessitates a large amount of time in both modeling and solving with complexity for every motor design, and the curve-fitting requires the data of flux linkage from either an experimental test or an FEA simulation. In this paper, phase inductance is predicted by means of a permeance method, and the proposed approach is analytically verified in terms of the accuracy of estimated inductance compared to inductance obtained by FEA.

The estimation on the insulation performance of thermal insulation materials according to water vapor permeance (투습성에 따른 단열재의 단열성능평가 및 고찰)

  • Kim, Seok-Hyun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF