• Title/Summary/Keyword: Periotest$^{(R)}$

Search Result 35, Processing Time 0.023 seconds

Clinical Evaluation of Tooth Mobility Following Root Planing and Flap Operation (치근활택술과 치은박리소파술 후 치아동요도 변화에 관한 연구)

  • Pang, Eun-Kyoung;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.893-914
    • /
    • 1999
  • Tooth mobility may be the decisive factor that determines whether dental treatment of any kind is undertaken. Although tooth mobility in isolation says little in itself, the finding of increased tooth mobility is of both diagnostic and prognostic importance. Only the detection of an increase or decrease in mobility makes an evaluation possible. Thus prior to treatment, we must understand the pathologic process causing the observed the tooth mobility and decide whether the pattern and degree of observed tooth mobility is reversible or irreversible. And then it must be decided whether retention and treatment or extraction and replacement. The purpose of this study was to compare tooth mobility at different time period during root planing and flap operation and to relate changes in mobility to each treatment method. Twenty-one patients (287 teeth) with chronic adult periodontitis were treated with root planing(control group) and flap operation(experimental group), and each group was divided 3 subgroups based upon initial probing pocket depth (1-3mm, 4-6mm, 7mm and more). Tooth mobility was measured with $Periotest^{(R)}$ at the day of operation, 4 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 8 weeks, 12 weeks after each treatment. Tooth mobility, attachment loss, radiographic bone loss, and bleeding on probing were measured at the day of operation, 4 weeks, 8 weeks and 12 weeks after treatment. 1. In group initial probing depth was 1-3mm, tooth mobility had no significant difference after root planing and flap operation. 2 . In group initial probing depth was 4-6mm, 7mm and more, tooth mobility had decreased in 12 weeks after root planing(p<0.01). And the mobility had increased after flap operation(p<0.01) and was at peak in 1 week, and decreased at initial level in 4 weeks, below the initial level in 12 weeks(p<0.01). 3. In 1 week, significant difference in tooth mobility between control and experimental group was found(p<0.01) but, in 12 weeks no difference between two groups was found. 4. Change of immediate tooth mobility after treatment was more larger in deep pocket than in shallow one. In group with the same probing pocket depth, the change of tooth mobility in molar group was greater than that of premolar group. 5. Tooth mobility before treatment was more strongly correlated with radiographic bone loss (r=0.5325) than probing depth, attachment loss and bleeding on probing, in 12 weeks after treatment, was more strongly correlated with attachment loss($r^2$=0.4761) than probing depth and bleeding on probing. Evaluation of the treatment effect and the prognosis after root planing and flap operation were meaningful on tooth initial probing depth 4mm and more. After flap operation, evaluation of the prognosis should be performed at least in 4 weeks and in 12 weeks after treatment, no difference in tooth mobility between two groups was observed. Radiographic bone loss and attachment loss were good clinical indicators to evaluate tooth mobility.

  • PDF

Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs (성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구)

  • Sun, Ki-Jong;Park, Jae-Young;Jung, Eun-Gyeong;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.209-221
    • /
    • 2007
  • Recently, immediately after losing teeth. implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materals, $STAGE-1^{(R)}$($4.1{\times}8mm$, Lifecore, USA), $SS-III^{(R)}$($4.0{\times}8mm$, OSSTEM, Korea) and $IFI^{(R)}$($4.0{\times}8mm$, Dio, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed $-2\;{\sim}\;-5$ and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among group(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%. respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

A CLINICAL AND RADIOLOGICAL STUDY ON THE EFFECT OF SYNTHETIC BONE IN CLASS II AND III FURACATION INVOLVEMENTS (2급 및 3급 치근이개부 병변에서 합성골이식의 효과에 대한 임상적 및 방사선학적 연구)

  • Yum, Kyu-Sun;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.475-492
    • /
    • 1993
  • The effect of synthetic bone materials was assessed in the patients with pure periodontal class II and III furcation defects. The buccal aspects of the maxillary and mandilular first and second molars were surgically exposed, and synthetic bone materials were interposed between the gingival flap and the furcation defects in the experimental group. The control group were treated without the use of synthetic bone materials by same operator. Probing pocket depth, gingival recession, and loss of attachment, were measured by Michigan O-probe and tooth mobility was evaluated by an electronic mobility tester(Periotest(R), Siemens co. Germany) at preoperation and 3-, 6-, and 12-month postoperation. Standardized radiogrphs were taken at preoperation and 6-month and 12-month postoperation. The postoperative change of clinical parameters and the difference between experimental group and control group were statistically analyzed by Student, t-test. The results were as follows: 1. The probing pocket depth at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at preoperative examination in both experimental group and control group(P<0.005), but there was no significantly difference between experimental group and control group. 2. The amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was increased, compared to that at the preoperative examination in both experimental and control group(P<0.005). In the case of the class III furcation involvement, the amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was more significantly increased in control group than experimental group(P<0.05). 3. The amount of loss of attachment at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group in the case of class II furcation involvement, and in experimental group only in the case of furcation III involvement(P<0.005). The amount of loss of attachment at, the 3-, 6-, and 12-month postoperative examination was more significantly decreased in experimental group than control group in the case of the class III furcation involvement(P<0.05), but in the case of class II furcation involvement there was no significant difference between experimental group and control group. 4. The tooth mobility at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group(P<0.005), but there was no significant difference between experimental group and control group. 5. Radiopacity of furcation area was greatly increased in the experiment group, but there was no radiographic change in the control group.

  • PDF