• Title/Summary/Keyword: Periodic Heating

Search Result 52, Processing Time 0.027 seconds

New Instabilities in Accretion Flows onto Black Holes

  • MOLTENI D.;FAUCI F.;GERARDI G.;BISIKALO D.;KUZNETSOV O.;ACHARYA K.;CHAKRABARTI S.
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.4
    • /
    • pp.247-249
    • /
    • 2001
  • The accretion disks are usually supposed symmetric to reflection on the Z=0 plane. Asymmetries in the flow are be ver-y small in the vicinity of the compact accretor. However their existence can have a important role in the case of subkeplerian accretion flows onto black holes. These flows lead to strong heating and even to the formation of shocks close to the centrifugal barrier. Large asymmetries are due to the development of the KH instability triggered by the small turbulences at the layer separating the incoming flow from the out coming shocked flow. The consequence of this phenomenon is the production of asymmetric outflows of matter and quasi periodic oscillations of the inner disk regions up and down the Z=0 plane.

  • PDF

A Study on Thermally-Induced Vibration of Flexible Space Structures (유연 우주구조물의 열적 유기 진동에 관한 연구)

  • Gong, Chang-Deok;O, Gyeong-Won;Y.Sugiyama
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.46-54
    • /
    • 2003
  • The purpose of this study is to analyze the phenomena of the thermally-induced vibration for the flexible space structure due to abrupt change of radiation heating circumstance using the numerical analyze and experiment test. In order to verify this structure, numerical approaches on the simplified flexible tube were compared with experimental test results at the ground experimental facility. In this analyze, it was found that the thermal deformation occurs firstly due to fast radiation heating of flexible structure and then the thermally-induced vibration would be induced due to small periodic change of temperature. According to comparison of numerical and experimental results, in case of no tip mass, the first mode vibration by the numerical analyze was a.78Hz same as that of the experimental result. However in case of increase tip-masses of 8g, 16g, 50g and 100g, the first modes vibration theoretical analyze were 1.75Hz, I.3Hz, a.87Hz and 0.73Hz, in decrease trend respectively and those by experimental test were 2.34Hz, 1.5Hz, 0.78Hz and 0.78Hz in decrease trend respectively. Although using the simpled equation for the estimation, the estimation results were similar to experimental results.

Establishment of Climate Region by Recent 30-year Temperature Range in South Korea Area (남한지역의 최근 30년간 기온분포에 의한 기후권역 설정)

  • Ryu, Yeon-Soo;Park, Mi-Lan;Kim, Jin-Wook;Joo, Hye-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.376-382
    • /
    • 2011
  • Since the Industrial Revolution has caused global change by using of a fossil fuel, a reckless and growth-oriented development. A global mean temperature since 19th century has climbed up 0.4~$0.8^{\circ}C$. Our country, afterwards, global warming has increased the temperature every season. After The Kyoto Protocol regarding a greenhouse gas reduction goal took effect, be situations that decrease of greenhouse gas was acutely required. Therefore, interest of utilization of the new & renewable energy is increasing everyday. In advanced research, we shows that at first divided a country to nine range by natural geography, and second executed Meteorological data analysis of recent 30 years considering level of significance by nine range. The results of advanced research are that the similarities are low because there are the regions that temperature deviation of the similar climate regions is large in winter season, and there are not characteristics of clear discrimination of temperature. This study shows that at first divided a country to six range by temperature range, and second executed Meteorological data analysis of recent 30 years considering level of significance by six range. The results of this study are that in heating load calculation of building, periodic temperature data management is required because facility capacity and cost are affected greatly by outdoor temperature, and temperature by climate range needs consideration of pertinent area. Ground temperature was assumed of the weather in region, the ground and soil. Lastly, we were able to know that establishment of climate region by temperature range can be useful policy making and plans of design of the horticultural facilities and architectures.

  • PDF

A Molecular Dynamics Study on the Liquid-Glass-Crystalline Transition of Lennard-Jones System (한 Lennard-jones 시스템의 액체-유리-결정 전이에 관한 분자동역학 연구)

  • Chang, Hyeon-Gu;Lee, Jong-Gil;Kim, Sun-Gwang
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.678-684
    • /
    • 1998
  • By means of constant- pressure molecular dynamics simulations, we studied the liquid- glass- crystalline transition of a system composed of Lennard- Jones particles with periodic boundary conditions. Atomic volume and enthalpy were calculated as functions of temperature during heating and cooling processes. The Wendt- Abraham ratio derived from radial distribution function and the angular distribution function characterizing short range order were analyzed to distinguish between liquid, glass and crystalline states. A liquid phase resulting from a slow heating of an initial fee crystal amorphized on fast quench, but it crystallized on slow quench. When slowly heated, the amorphous phase from fast quench crystallized into an fee structure. A system with free surface was shown to melt from the surface inward at a lower temperature than bulk system and to have a strong tendency for crystallization even during a fast quench from a liquid state.

  • PDF

Active control of amplitude and phase of high-power RF systems in EAST ICRF heating experiments

  • Guanghui Zhu;Lunan Liu;Yuzhou Mao;Xinjun Zhang;Yaoyao Guo;Lin Ai;Runhao Jiang;Chengming Qin;Wei Zhang;Hua Yang;Shuai Yuan;Lei Wang;Songqing Ju;Yongsheng Wang;Xuan Sun;Zhida Yang;Jinxin Wang;Yan Cheng;Hang Li;Jingting Luo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.595-602
    • /
    • 2023
  • The EAST ICRF system operating space has been extended in power and phase control with a low-level RF system for the new double-strap antenna. Then the multi-step power and periodic phase scanning experiment were conducted in L-mode plasma, respectively. In the power scanning experiment, the stored energy, radiation power, plasma impedance and the antenna's temperature all have positive responses during the short ramp-ups of PL;ICRF. The core ion temperature increased from 1 keV to 1.5 keV and the core heating area expanded from |Z| ≤ 5 cm to |Z| ≤ 10 cm during the injection of ICRF waves. In the phasing scanning experiment, in addition to the same conclusions as the previous relatively phasing scanning experiment, the superposition effect of the fluctuation of stored energy, radiation power and neutron yield caused by phasing change with dual antenna, resulting in the amplitude and phase shift, was also observed. The active control of RF output facilitates the precise control of plasma profiles and greatly benefits future experimental exploration.

Measurement of Focal Spot Size of Heavy Loaded X-ray Tubes (X선관의 실효초점 측정에 관한 고찰)

  • Chang, Kwang-Hyun;Lim, Oh-Soo;Kim, Hyung-Kee;Song, Chang-Wook;Cheung, Kyung-Mo;Cheung, Hwan
    • Journal of radiological science and technology
    • /
    • v.16 no.1
    • /
    • pp.101-106
    • /
    • 1993
  • In order to assure safety of both patient and operator, and to provide uniform quality radiographs, it is necessary to perform periodic calibration of diagnostic X-ray equipment. A basic parameter of diagnostic equipment's and its image sharpness is the size(and shape the energy distribution) of the focal spot as viewed along the central X-ray beam. This size determines the resolution possible with the equipment and also determines the heat characteristics of an anode. A fine focus tube gives high resolution but causes high local heating of target. In past, the pin-hole and star pattern image measurement for evaluation of resolution have been widely used, but it produced blurring and inaccuracy of image. So newly inverted Ug-meter has advantage in more convenient measurement method and less out-put bias than other image measurement. The authors intended to compare measured focal size between Ug-meter and focal spot test tool, changed state from setting to now of units.

  • PDF

A Study of the Non-Fourier Heat Conduction Phenomena (비푸리에 열전도 현상에 관한 고찰)

  • Choi, Soon-Ho;Jin, Chang-Fu;Choi, Hyun-Kue;Yun, Seok-Hoon;Kim, Myoung-Hwan;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.37-38
    • /
    • 2005
  • Although the law of classical fourier heat conduction predicts the heat conduction phenomena occurred in most engineering fields with a good accuracy, it is also well-known that the conventional fourier law of a heat conduction has an application limit when the heating and cooling are periodic for a short duration or when the heat conduction is analyzed in the extremely low temperature region. This application limit of classical fourier law results from the fact that it assumed the infinite speed of a heat wave. In this study, we investigated the feasibility of whether the molecular dynamics could be used to calculate the speed of a heat wave through a solid. The calculated sound velocity showed a good agrement with the theoretical prediction qualitatively. From the calculated results, we confirmed that the same methodology can be applied the evaluation of the speed of a heat wave.

  • PDF

Metal Forming Simulation with Emphasis on Metal Flow Lines and its Applications (소성유동선도를 강조한 소성가공 시뮬레이션과 그 적용 사례)

  • Eom, J.G.;Jeong, S.W.;Joun, M.S.
    • Transactions of Materials Processing
    • /
    • v.22 no.6
    • /
    • pp.323-327
    • /
    • 2013
  • In this paper, the flow lines as a function of product design as well as the forging process design are explored using typical application examples. The prediction of flow lines using metal forming simulation technology is introduced along with their characterization. Experimental studies have shown that the metal flow lines have a strong influence on the structural rigidity of the final product. In this study we present several typical applications. One example is the case of severely cut metal flow lines during machining, especially in the region where periodic contacting forces are applied. Another example is the case of abnormal distortion of flow lines which can cause too much elongation or hot shortness due to viscous heating in the region of distortion. A third example is the case of a macrosegregation region which needs to be controlled so it is not adjacent to the region where the force is applied in the use of the final component. An example of weight reduction for an automobile component with improved flow lines is also introduced. These typical applications can provide process engineers with the insight in designing automobile or mechanical components as well as in designing the manufacturing methods to produce various parts.

Fault Diagnosis Device for Fire Prevention of the Resistance Heating Type three-Phase Electric Heater (3상 저항가열식 전기히터의 화재예방을 위한 결함 진단장치)

  • Lee, Mun-Hyung;Kim, Chan-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.11
    • /
    • pp.1669-1674
    • /
    • 2017
  • In this study, We have discussed the development of a diagnostic device to detect and prevent electrical fire due to the arc caused by contact failure and partial disconnection at the connection part of the three-phase electric heater wiring used in the industrial field. The arc caused by contact failure and partial disconnection at the connection part of the electric heater shows a change in the current effective value. Therefore, it is possible to determine whether there exists a defect by analyzing the current unbalance factor and the number of current fluctuations with the diagnostic apparatus. The three-phase unbalanced heater is considered to be capable of determining defects through periodic measurement and trend analysis of the current unbalance factor. It is also expected that this device can be used not only for electric heaters but also for detection of defects in wiring and connections of electrical equipment having a characteristic of constant load current.

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF