• Title/Summary/Keyword: Period shift

Search Result 475, Processing Time 0.022 seconds

A Development of Parallel Type Hybrid Drivetrain System for Transit Bus Part 6 : A Development of Shift Control Algorithm for Improving the Shift Characteristics of the Hybrid Drivetrain with AMT (버스용 병렬형 하이브리드 동력전달계의 개발 (VI) 제 6 편 : 하이브리드 동력전달계용 자동화 변속기의 변속 질 향상을 위한 변속 제어 알고리듬의 개발)

  • 조성태;전순일;조한상;박영일;이장무
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.105-114
    • /
    • 2001
  • In this study, a shift control algorithm far improving the shift quality of a parallel hybrid drivetrain with an automated manual transmission (AM) is proposed. The general AMT requires the sophisticated control of clutch in the clutch engagement to improve its shift characteristics, and that is generally known to be difficult. But in this hybrid drivetrain, we can control the speeds of clutch plates by engine and motor control, and it provides the easier clutch control in shift process than general AMT. Additionally, it permits the much-reduced shift shock. The motor control during the shift period is also to achieve reduced velocity drop of the vehicle in comparison with that of a general AMT. Furthermore various dynamometer-based experiments are carried out to prove the validity of the proposed shift control algorithm.

  • PDF

Problems of Working Hours and Shift Work Systems, and Propsed Methods for Their Improvement (근로시간 및 교대근무편성의 문제점과 개선방향)

  • Seo, Yu-Jin;;Park, Yeong-Man;Mun, Se-Geun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.13-26
    • /
    • 2003
  • The purpose of this study is to investigate the present conditions of the night work and shift work systems in the heavy chemical industrial complexes found in Changwon, Masan, and Chinhae. Korea. We will attempt to define and classify their problems; and to discover further ways to improve their systems. Fifty production factories were carefully selected as the subjects for this study. The shift systems were classified into five categories. The consecutive night shifts were long in almost all cases with 6 days (36 factories) and 7 days (13 factories). It was found that the night work of about] 2 hours continues for a long period in the weekly rotation full-day shift systems and the night-including non-full-day shift systems, and there was no holiday during a shift cycle in the continuous full-day shift systems. The work time in most shift systems was longer than the 44-hours/week permitted by Korean law. Considering the characteristics of these various types of shift systems, the most essential thing to reduce the shift workers' work load may be to shorten their working hours and improve the schedule of shift systems. It is highly recommended as a fundamental solution. to reduce the portal-to-portal hours from 12 to 8 in the night-including non-full-day shift systems and the weekly rotation full-day shift systems, and at least to employ a 4-team 3-shift system in the continuous full-day shift systems. In addition to this, it should from now on be taken as a goal to restructure the types of shift systems by taking such measures as avoiding continuous night work if possible, providing sufficient off-duty intervals both before and after night shift, providing increased opportunities for workers to nap during night work. and increasing the number of holidays.

Effect of Shift Interval for the Clinical Nurse on the Circadian Rhythm (임상 간호사의 교대근무 기간이 circadian rhythm 변화에 미치는 영향)

  • 황애란;정현숙;임영신;이혜원;김조자
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.2
    • /
    • pp.129-149
    • /
    • 1991
  • Circadian rhythm is entrained in the 24-hour time interval by periodic factors in the environment, known as zeitgeber. But most rotating work schedules are outside the range of the entrainment of the pacemaker timing the human circadian sleep - wake cycle. It has been postulated that physiological and emotional disturbances occur in most human functions when the circadian rhythm is disturbed. So application of circadian principles to the design of shift schedules can aid in maintaining the temporal integrity of the circadian system and thereby minimize for the shift worker any detrimental consequences of circadian disruption. This study was a quasi-experimental study to test the effect of shift intervals for the clinical nurse on the circadian rhythm. Twenty nurses newly employed in general units of two hospitals were selected as an experimental group and twelve college nursing students as a control group. Both groups were selected according to an established criteria using a purposive sampling technique. Ten subjects were assigned to a weekly shift group and another ten to a biweekly shift group engaged in a semi -continuous shift schedule(sunday off) with a backward direction, that is, morning -evening - night shift. The control group worked a morning shift for 42 days. Oral temperature rhythm, waking tim, sleep - wake cycle, fatigue, and mental performance were measured during the experimental period. The data collection period was from April 30, 1990 to June 10, 1990. MANOVA, paired t-test, ANOVA, and Student Newman Keuls method were used for statistical analysis. The results are summarized as follows. 1. Phase delay in the acrophase of temperature rhythm was shown according to the backward rotating shift. A complete adaptation to work on the night shift was achieved between the sixth and ninth day of the night shift. 2. There was no difference in either waking time or sleep- wake cycle according to the duration of the working day for every shift group. Significant difference was found in the waking time and the sleep -wake cycle for subjects on the morning, evening, and night shift in both of the shift groups(weekly shift group : λ=0.121, p<0.01, λ=0.112, p<0.01, biweekly shift group : λ=0.116, p<0.01, λ=0.084, p<0.01). 3. There was no difference in fatigue between the first working day and the last working day for the control group and for the biweekly shift group. In the weekly shift group, physical fatigue was significantly different for the first day and the sixth day of the night shift(t=-2.28, p<0.05). Physical fatigue and total fatigue on the first day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=5.79, p<0.01, F=4.56, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05), Physical fatigue, neurosensory fatigue and total fatigue on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=12.65, p<0.01, F=7.77, p<0.01, F=9.68, p<0.01). There was a significant difference between the shift groups and the control group(p<0.05). 4. No difference in mental performance was seen between the first day and the last day of work in each case. An arithmatic test on the first day of the night shift revealed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.79, p<0.05). There was a significant difference between the shift groups and the control group(p<0.05) . The digital symbol substitution test and the arithmetic test on the last day of the night shift showed a significant difference among the control group, the weekly shift group, and the biweekly shift group(F=3.68, p<0.05, F=5.55, p<0.01), and both showed a significant difference between the shift groups and the control group(p<0.05). Accordingly, this study showed that during night duty, the waking time, sleep- wake cycle, and fatigue increased and mental performance decreased compared with morning and evening duty. It was also found that the weekly shift group had a higher fatigue score on the sixth day of night duty as compared to the -first day, but the waking time, sleep- wake cycle, and mental performance revealed no difference for the duration of the night duty or between shift groups, and complete adaptation of temperature rhythm was achieved between the sixth and ninth day of night duty. It is possible to conclude from these results that for intermediate circadian type in a healthy young woman, a biweekly shift system is more compatible with the circadian timing system than weekly shift system.

  • PDF

On the Origin of the Oosterhoff Dichotomy among Globular Clusters and Dwarf Galaxies

  • Jang, Sohee;Lee, Young-Wook;Joo, Seok-Joo;Na, Chongsam
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.67.2-67.2
    • /
    • 2014
  • The presence of multiple populations is now well-established in most globular clusters in the Milky Way. In light of this progress, here we suggest a new model explaining the origin of the Sandage period-shift and the difference in mean period of type ab RR Lyrae variables between the two Oosterhoff groups. In our models, the instability strip in the metal-poor group II clusters, such as M15, is populated by second generation stars (G2) with enhanced helium and CNO abundances, while the RR Lyraes in the relatively metal-rich group I clusters like M3 are mostly produced by first generation stars (G1) without these enhancements. This population shift within the instability strip with metallicity can create the observed period-shift between the two groups, since both helium and CNO abundances play a role in increasing the period of RR Lyrae variables. The presence of more metal-rich clusters having Oosterhoff-intermediate characteristics, such as NGC 1851, as well as of most metal-rich clusters having RR Lyraes with longest periods (group III) can also be reproduced, as more helium-rich third and later generations of stars (G3) penetrate into the instability strip with further increase in metallicity. Therefore, although there are systems where the suggested population shift cannot be a viable explanation, for the most general cases, our models predict that the RR Lyraes are produced mostly by G1, G2, and G3, respectively, for the Oosterhoff groups I, II, and III.

  • PDF

A Study on a Binary Random Sequence Generator with Two Characteristic Polynomials (두개의 특성 다항식으로 구성된 이진 난수열 발생기에 관한 연구)

  • 김대엽;주학수;임종인
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.3
    • /
    • pp.77-85
    • /
    • 2002
  • A Research of binary random sequence generator that uses a linear shift register had been studied since the 1970s. These generators were used in stream cipher. In general, the binary random sequence generator consists of linear shift registers that generate sequences of maximum period and a nonlinear filter function or a nonlinear combination function to generate a sequence of high linear complexity. Therefore, To generate a sequence that have long period as well as high linear complexity becomes an important factor to estimate safety of stream cipher. Usually, the maximum period of the sequence generated by a linear feedback shift register with L resistors is less than or equal to $2^L$-1. In this paper, we propose new binary random sequence generator that consist of L registers and 2 sub-characteristic polynomials. According to an initial state vector, the least period of the sequence generated by the proposed generator is equal to or ions than it of the sequence created by the general linear feedback shift register, and its linear complexity is increased too.

The Effect of Shift Work on the Diurnal Rhythm of Blood Pressure in Nurses (간호사의 야간교대근무로 인한 혈압의 일중 변동 양상)

  • Lee, An-Saeng;Rhee, Sang-Jae;Kim, Nam-Ho
    • Korean Journal of Occupational Health Nursing
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: This study was performed to investigate the effect of shift work on diurnal blood pressure (BP) pattern in nurses. Method: We studied 20 healthy nurses engaged in 3 shift work. 24-hour ambulatory BP monitoring was performed to each nurse two times during the day and night shift. Five nurses were excluded because of inadequate BP measurement. Results: All subjects were female. The mean age was 27.4 years (range: 23-33 years) and mean body mass index was 19.7 Kg/$m^2$ (range: 18.0-21.2 Kg/$m^2$). The changes of systolic BP ($17.8{\pm}9.1$ vs. $13.2{\pm}4.7%$, p=0.031), diastolic BP ($22.3{\pm}8.7$ vs. $17.3{\pm}9.0%$, p=0.061), and heart rate ($25.2{\pm}5.2$ vs. $12.5{\pm}8.7%$, p=0.001) during the sleeping period were decreased after a night shift compared with day shift. The non-dipper group significantly increased from 20% to 40% after a night shift (p=0.018). Conclusion: Working night shift is significantly associated with non-dipper status in nurses.

  • PDF

A New Electrode Structure for Color-shift Reduction in PVA LCD

  • Kwon, Yong-Hoan;Baek, Jong-In;Kim, Jae-Chang;Yoon, Tae-Hoon
    • Journal of Information Display
    • /
    • v.8 no.3
    • /
    • pp.17-21
    • /
    • 2007
  • We introduce a new electrode structure for the patterned vertical alignment (PVA) mode, which has a lower color-shift at large viewing angle than the one-domain VA mode. By manipulating the period of electrode structure, we can make more multi-domains and use the existing fabrication processes without having to use additional materials.

The relationship between shift work pattern and thyroid stimulating hormone in female workers

  • Hun Jeong;Chang Ho Chae;Jun Ho Lee;Hyo Won Chong
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.14.1-14.10
    • /
    • 2023
  • Background: Shift work is known to cause changes in the circadian rhythm of the human body and adversely affect not only physical health but also mental health. Some studies have demonstrated the correlation between shift work and thyroid stimulating hormone (TSH), a hormone that changes according to the diurnal rhythm, but few studies have reported the different TSH levels according to the shift work type. This study aimed to investigate changes in TSH according to the shift work type. Methods: This study included 1,318 female workers who had a medical checkup at a university hospital in Changwon from 2015 to 2019. Shift work types were classified as non-shift work, regular 2 shifts, and irregular three shifts, and a TSH ≥ 4.2 mIU/L was defined as abnormal. A general linear model (GLM) was used to compare the TSH levels and the risk of subclinical hypothyroidism in each year, and a binary logistic analysis was performed using a generalized estimation equation (GEE) to compare the risk of subclinical hypothyroidism over the 5-year period. Results: Of the 1,318 participants included in this study, 363, 711, and 244 were non-shift, two-shift, and irregular three-shift workers, respectively. In the GEE analysis, after adjusting for age, body mass index, smoking, and alcohol consumption, the odds ratios (ORs) were 1.81 (95% confidence interval [CI]: 1.15-2.86; p = 0.011) in 2 shifts and 2.02 (95% CI: 1.23-3.32; p = 0.006) in irregular three shifts, compared to non-shift. Conclusions: Our results showed that shift work had a higher risk of subclinical hypothyroidism than non-shift work and that there was a significant difference in the risk of subclinical hypothyroidism according to the shift work type. These findings suggest that the shift work type can be considered in future thyroid function tests and evaluations.

A Periodic Analysis of Sidereal Shifts for GPS Satellites and the Solar Wind Stream

  • Cho, Changhyun;Choi, Byung-Kyu
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.6 no.2
    • /
    • pp.71-78
    • /
    • 2017
  • The sidereal day of a Global Positioning System (GPS) satellite was intended to equal one half of a sidereal day of the Earth. However, the sidereal day of GPS satellites has become unequal to one half of a sidereal day of the Earth. This is fundamentally caused by the non-sphericity of the Earth and the gravity of the Moon. The difference between sidereal days of GPS satellites and the Earth is known as a sidereal shift. The details surrounding sidereal shifts and their origins have yet to be fully understood. We calculated the periodicity of sidereal shifts for GPS satellites using broadcast ephemeris data. To conduct a periodic analysis of the sidereal shift, we employ the Lomb-Scargle periodogram method. It shows that the orbit periods of GPS satellites have small-amplitude perturbations with a 13.6-day period. In addition, we compare the GPS satellite orbit periods with the periodicity of geomagnetic indices and the solar wind parameters to identify the cause of the perturbations. Our results suggest that the solar wind stream might also affect the 13.6-day period of the sidereal shifts.

Design of Multipath Adaptive BISMO-Algorithm in the Underwater Communication (수중 통신시 다중경로 적응 BISMO (Bi-Switch Modulation)알고리즘 설계)

  • Im, Byung-Ook;Shim, Tae-Bo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.7
    • /
    • pp.342-349
    • /
    • 2008
  • Multipath makes clear message transfer difficult in the underwater communication. To solve this problem, we propose a new method producing proper MFSP (Modulation Frequency Shift Period) which could be obtained by calculating time delay caused by different path from a transmitter to a receiver. At the transmitter end, messages were divided according to the size of the MFSP and transmitted accordingly alternating Frequency. At the receiver end, the received messages were demodulated in order to recover the original message by the adaptive BISMO algorithm which is constructed at the algorithm design stage. Adaptive MFSP and estimated BER (Bit Error Rate) were calculated through simulation test.