• Title/Summary/Keyword: Perimeter

Search Result 500, Processing Time 0.061 seconds

Forest Fire Direction and Spread Characteristics by Field Investigations (사례 조사를 통한 산불 방향 및 확산 특성)

  • Lee, Byung-Do;Koo, Kyo-Sang;Lee, Myung-Bo
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.96-102
    • /
    • 2009
  • Forest fire ignition and spread characteristics are needed as basic data in fire management. Slope aspect of ignition point, spread direction, and wind direction at that time were analyzed and regression equations were proposed for predicting burned area, fire perimeter, head spread rate, and flank spread rate using combustion time using 101 forest fires broken out between 2007 and 2009 spring. 57% forest fires of investigated numbers were ignited in south, southwest, and southeast aspects and 68% of forest fires were spreaded to east, southeast, and northeast influenced by westerly wind. About 11.8ha forest was burned and 0.5km fire perimeter increase was predicted per hour. Head and flank spread rate were calculated 0.13km and 0.05km, respectively.

A Case of Idiopathic Peripheral Neuropathy Improved by Combined with Electroacupuncture and Bee Venom Acupuncture (전침 및 봉약침 치료로 호전된 특발성 말초신경병증의 증례보고)

  • An, SunJoo;Choi, Seonghwan;Kang, Shinwoo;Park, Seohyun;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.2
    • /
    • pp.173-181
    • /
    • 2020
  • The purpose of this study is to report the effects of electroacupuncture and bee venom (BV) acupuncture for a patient suffering with idiopathic peripheral neuropathy. There was a one patient who was diagnosed as idiopathic peroneal neuropathy and tibial neuropathy received electroacupuncture and BV acupuncture at acupoints on peroneal and tibial nerve pathway. The evaluation of clinical outcome was done by range of motion (ROM), manual muscle test (MMT), perimeter of lower leg, neuropathy pain scale (NPS). After treatment, the patient showed improvement in ROM and MMT. The patient's perimeter of lower leg was increased, NPS was decreased. This study suggests that the treatment of acupoints on the damaged nerve pathways could be an effective treatment for peripheral neuropathy, although further studies will be needed.

A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application (건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

A Watermarking Scheme for Shapefile-Based GIS Digital Map Using Polyline Perimeter Distribution

  • Huo, Xiao-Jiao;Lee, Suk-Hwan;Kwon, Seong-Geun;Moon, Kwan-Seok;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.5
    • /
    • pp.595-606
    • /
    • 2011
  • This paper proposes a robust watermarking scheme for GIS digital map by using the geometric properties of polyline and polygon, which are the fundamental components in vector data structure. In the proposed scheme, we calculate the lengths and the perimeters of all polylines and polygons in a map and cluster them to a number of groups. Then we embed the binary watermark by changing the mean of lengths and perimeters in an embedding group. For improving the safety and robustness, we permute the binary watermark through PRNS(pseudo-random number sequence) processing and embed it repeatedly in a model. Experimental results verified that our scheme has a good invisibility, safety and robustness to various geometric attacks and also our scheme needs not the original map in the extracting process of watermark.

Relationships for prediction of backstay effect in tall buildings with core-wall system

  • Karimi, Mahdi;Kheyroddin, Ali;Shariatmadar, Hashem
    • Advances in Computational Design
    • /
    • v.5 no.1
    • /
    • pp.35-54
    • /
    • 2020
  • One of the prevailing structural systems in high-rise buildings is the core-wall system. On the other hand, the existence of one or more underground stories causes the perimeter below-grade walls with the diaphragm of grade level to constitute of a very stiff box. In this case or a similar situation, during the lateral response of a tall building, underground perimeter walls and diaphragms that provide an increased lateral resistance relative to the core wall may introduce a prying action in the core that is called backstay effect. In this case, a rather great force is generated at the diaphragm of the grade-level, acting in a reverse direction to the lateral force on the core-wall system, and thus typically causes a reverse internal shear. In this research, in addition to review of the results of the preceding studies, an improved relationship is proposed for prediction of backstay force. The new proposed relationship takes into account the effect of foundation flexibility and is presented in a non-dimensional form. Furthermore, a specific range of the backstay force to lateral load ratio has been determined. And finally, it is shown that although all suggested formulas are valid in the elastic domain, yet with some changes in the initial considerations, they can be applied to some certain non-linear problems as well.

Application of BIPV System Functioned as Solar Collector (태양열 집열기 기능을 갖는 BIPV 시스템의 응용)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF

Application of shrinkage prediction models to restraint crack formation in unbonded post-tensioned slabs

  • Gabriela R. Martínez Lara;Myoungsu Shin;Yong-Hoon Byun;Goangseup Zi;Thomas H.-K. Kang
    • Computers and Concrete
    • /
    • v.33 no.4
    • /
    • pp.349-359
    • /
    • 2024
  • This study aims to investigate the effect of restraint configuration on crack formation due to shrinkage-and-creep-induced volumetric change in unbonded post-tensioned slabs. The first part of this study focuses on the comparison of existing shrinkage and creep calculation models that are used to predict the volume-changing behavior of concrete. The second part of this study presents the finite element analysis of a series of architectural configuration prototypes subjected to shrinkage and creep, which comprise unbonded post-tensioned slabs with various restraint configurations. The shrinkage and creep effects were simulated in the analysis by imposing strains obtained from one selected calculation model. The results suggest that a slab up to 300 ft. (90 m) in length does not require a closure strip if it is unrestrained by perimeter walls, and that the most effective restraint crack mitigation strategy for a slab restrained by perimeter walls is a partial wall release.

Experimental Study on the Characteristics of Ground Heat Exchange in Heating Greenhouses (난방 온실의 지중열 교환 특성에 관한 실험적 연구)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • The calculation method of ground heat exchange in greenhouses has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the soil temperature distribution and the soil heat flux in three plastic greenhouses of different size and location during the heating period. And then the calculation methods of ground heat exchange in greenhouses were reviewed. The soil temperature distributions measured in the heating greenhouse were compared with the indoor air temperature, the results showed that soil temperatures were higher than room temperature in the central part of greenhouse, and soil temperatures were lower than room temperature in the side edge of greenhouse. Therefore, it is determined that the ground heat gain in the central part of greenhouse and the perimeter heat loss in the side edge of greenhouse are occurred, there is a difference depending on the size of greenhouse. Introducing the concept of heat loss through the perimeter of building and modified to reflect the size of greenhouse, the calculation method of ground heat exchange in greenhouses is considered appropriate. It was confirmed that the floor heat loss measured by using soil heat flux sensors increased linearly in proportion to the temperature difference between indoor and outdoor. We derived the reference temperature difference which change the direction of ground heat flow and the perimeter heat loss factor from the measured heat flux results. In the heating design of domestic greenhouses, reference temperature differences are proposed to apply $12.5{\sim}15^{\circ}C$ in small greenhouses and around $10^{\circ}C$ in large greenhouses. Perimeter heat loss factors are proposed to apply $2.5{\sim}5.0W{\cdot}m^{-1}{\cdot}K^{-1}$ in small greenhouses and $7.5{\sim}10W{\cdot}m^{-1}{\cdot}K^{-1}$ in large greenhouses as design standard data.

Characteristics of Tamarix chinensis Population in Shiwha Lake (시화호 내 위성류(Tamarix chinensis) 개체군의 특성)

  • Min, Byeong-Mee;Yi, Dong-Hoon;Lee, Hye-Won;Choi, Jong-In
    • The Korean Journal of Ecology
    • /
    • v.28 no.5
    • /
    • pp.327-333
    • /
    • 2005
  • For the first time in Korea, plant size, distribution pattern and root growth form of Tamarix chinensis were surveyed at natural stand in Shiwha Lake, from June to July in 2005. T, chinensis grew in the range of 350 m towards north-south and 270 m in east-west direction. The mean number of stems germinated from same root system was 1.9. On the stem base, the numbers of living and dead plants were 1,398 and 114, respectively. Mean perimeter and height of 1,398 plants were $5.9{\pm}3.2$ cm and $159{\pm}51$ cm, respectively. By dividing into 10 classes based on the perimeter size, the largest number of plants were included in the second smallest class category. However, by dividing into 10 classes on the bases of plant height, variation in the number of plants along the height showed normal distribution curve. The heights of dead plants were small in perimeter but diverse in height. On the root base, the number of plants was the greatest in the smallest size class, and conspicuously decreased with size increment. Distribution of T. chinensis was clumped pattern. Age of the largest plant was 8-year. T. chinensis had two types of root growth. One was horizontal growth in the periphery of soil surface, and the other vertical growth.

An Assessment of Air Sampling Location for Stack Monitoring in Nuclear Facility (원자력시설 굴뚝 내 공기시료채취 위치의 적절성 평가)

  • Lee, JungBok;Kim, TaeHyoung;Lee, JongIl;Kim, BongHwan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.2
    • /
    • pp.173-180
    • /
    • 2017
  • In this study, air sampling locations in the stack of the Advanced Fuel Science Building (AFSB) at the Korea Atomic Energy Research Institute (KAERI) were assessed according to the ANSI/HPS N13.1-1999 specification. The velocity profile, flow angle and $10{\mu}m$ aerosol particle profile at the cross-section as functions of stack height L and stack diameter D (L/D) were assessed according to the sampling location criteria using COMSOL. The criteria for the velocity profile were found to be met at 5 L/D or more for the height, and the criteria for the average flow angle were met at all locations through this assessment. The criteria for the particle profile were met at 5 L/D and 9 L/D. However, the particle profile at the cross-section of each sampling location was found to be non-uniform. In order to establish uniformity of the particle profile, a static mixer and a perimeter ring were modeled, after which the degrees of effectiveness of these components were compared. Modeling using the static mixer indicated that the sampling locations that met the criteria for the particle profile were 5-10 L/D. When modeling using the perimeter ring, the sampling locations that met the criteria for particle profile were 5 L/D and 7-10 L/D. The criteria for the velocity profile and the average flow angle were also met at the sampling locations that met the criteria for the particle profile. The methodologies used in this study can also be applied during assessments of air sampling locations when monitoring stacks at new nuclear facilities as well as existing nuclear facilities.