• 제목/요약/키워드: Peri-implant bone loss

검색결과 75건 처리시간 0.028초

Quantitative measurement of peri-implant bone defects using optical coherence tomography

  • Kim, Sulhee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Bome;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.84-91
    • /
    • 2018
  • Purpose: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. Methods: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. Results: The average defect depth measured by a digital caliper was $4.88{\pm}1.28mm$, and the corresponding OCT measurement was $5.11{\pm}1.33mm$. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. Conclusions: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

The influence of the implant-abutment complex on marginal bone and peri-implant conditions: A retrospective study

  • Tokgoz, Selen Ergin;Bilhan, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권1호
    • /
    • pp.46-54
    • /
    • 2021
  • Purpose. The design of the implant-abutment complex is thought to be responsible for marginal bone loss (MBL) and might affect the condition of the peri-implant tissues. This the present study aimed to evaluate the influence of the implant-abutment complex on MBL and the peri-implant tissues in partially edentulous patients treated with dental implants and determine the most advantageous design. Materials and Methods. A total of ninety-one endosseous implants with different designs of implant-abutment complex [tissue level-TL (n = 30), platform switch-PS (n = 18), and platform match-PM (n = 43)] were reviewed for MBL, Probing Pocket Depth (PPD) and Bleeding on Probing (BoP). MBL was calculated for first year of the insertion and the following years. Results. The median MBL for the PM implants (2.66 ± 1.67 mm; n = 43) in the first year was significantly higher than those for the other types (P=.033). The lowest rate of MBL (0.61 ± 0.44 mm; n = 18) was observed with PS implants (P=.000). The position of the crown-abutment border showed a statistically significant influence (P=.019) and a negative correlation (r=-0.395) on MBL. BoP was found significantly higher in PM implants (P=.006). The lowest BoP scores were detected in PS implants, but the difference was not significant (P=.523). The relation between PPD and connection type revealed no statistically significant influence (P>.05). Conclusion. Within the limitations of the present study, it may be concluded that PS implants seem to show better peri-implant soft tissue conditions and cause less MBL.

임플란트 주위염의 치료: 증례보고 (Treatment of Peri-implantitis: Cases Report)

  • 성헌모;김경규
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권2호
    • /
    • pp.112-123
    • /
    • 2013
  • This study aims to investigate the clinical outcome following treatment of peri-implantitis lesions. Five subjects with 7 implants were treated with surgical approach. Four subjects with 6 implants were initially treated with non-surgical approach or hygiene control. However, inflammation was not resolved and more bone loss was found. Therefore, surgical treatment was performed. After surgical exposure of the defect, granulation tissue was removed and implant surface was treated using tetracycline and chlorhexidine. Then, the flaps were sutured. The wound healing was performed in a non-submerged mode. The present finding demonstrates stable results without progression of bone loss. In one subject, deep V shaped bone defect was filled with bone substitute (ICB, CanCellous Bone, Rockey Mountain Tissue Bank, USA), and resorbable membrane (Lyoplant$^{(R)}$, B.Braun Aesculap AG, Germany) was placed over the grafted defect and healing abutment was connected. However, the inflammation was not resolved and more bone loss was found. At one month after regenerative surgery, the implant was removed.

패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석 (Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm)

  • 정민기;김성민;김명주;이종호;명훈;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권3호
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment

  • Seo, Yong-Ho;Bae, Eun-Bin;Kim, Jung-Woo;Lee, So-Hyoun;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.313-320
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS. Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS. Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION. The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.

Long-term outcomes after peri-implantitis treatment and their influencing factors: a retrospective study

  • Lee, Sung-Bae;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • 제52권3호
    • /
    • pp.194-205
    • /
    • 2022
  • Purpose: This study aimed to determine the long-term outcomes after peri-implantitis treatment and the factors affecting these outcomes. Methods: This study included 92 implants in 45 patients who had been treated for peri-implantitis. Clinical data on the characteristics of patients and their implants were collected retrospectively. The change in the marginal bone level was calculated by comparing the baseline and the most recently obtained (≥3 years after treatment) radiographs. The primary outcome variable was progression of the disease after the treatment at the implant level, which was defined as further bone loss of >1.0 mm or implant removal. A 2-level binary logistic regression analysis was used to identify the effects of possible factors on the primary outcome. Results: The mean age of the patients was 58.7 years (range, 22-79 years). Progression of peri-implantitis was observed in 64.4% of patients and 63.0% of implants during an observation period of 6.4±2.7 years (mean±standard deviation). Multivariable regression analysis revealed that full compliance to recall visits (P=0.019), smoking (P=0.023), placement of 4 or more implants (P=0.022), and marginal bone loss ≥4 mm at baseline (P=0.027) significantly influenced the treatment outcome. Conclusions: The long-term results of peri-implantitis treatment can be improved by full compliance on the part of patients, whereas it is impaired by smoking, placement of multiple implants, and severe bone loss at baseline. Encouraging patients to stop smoking and to receive supportive care is recommended before treatment.

임플란트의 생존과 변연골 소실에 영향을 미치는 인자들 (Factors associated with the survival and marginal bone loss of dental implants: a 5-year retrospective study)

  • 송을락;이재관;엄흥식;박세환;장범석
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.280-292
    • /
    • 2016
  • 목적: 이 연구의 목적은 임플란트의 생존율과 주위 변연골 수준을 후향적으로 평가하여, 술자의 임상적 경험을 포함한 요인들이 미치는 영향을 분석하고자 하였다. 연구 재료 및 방법: 2002년 1월부터 2009년 3월까지 강릉원주대학교치과병원 치주과에서 전공의가 2단계법으로 식립한 임플란트 중 5년 이상의 기록이 있는 146명의 420개 임플란트를 대상으로, 임플란트 탈락여부, 주위 골 소실량, 성별, 연령, 2형 당뇨, 흡연, 지대주 연결 형식, 표면 처리 방법, 직경, 식립 부위, 식립 당시 전공의 연차, 덮개 나사의 조기 노출, 보철학적 합병증, 동반된 골 이식 술식 등의 영향을 평가하였다. 결과: 최종 보철물 장착 후 5년간 누적생존율은 94.9% 이었다. 이원로지스틱회귀분석 결과, 흡연과 덮개 나사의 조기 노출이 실패율을 유의하게 증가시켰다. 다중회귀분석 결과, 흡연, 임플란트 지대주 연결 형식, 및 표면 처리 방법이 임플란트 주위 변연골 수준 변화에 유의한 영향을 주었다. 술자의 임상경험을 반영하기 위한 식립 당시의 전공의 수련 연차는 임플란트의 실패와 유의한 연관성은 보이지 않았다(P = 0.171). 결론: 흡연, 덮개 나사의 조기 노출, 지대주 연결 형식 및 표면 처리 방법이 임플란트의 성공과 유의한 상관관계를 보이는 것으로 생각된다.

Retrospective long-term analysis of bone level changes after horizontal alveolar crest reconstruction with autologous bone grafts harvested from the posterior region of the mandible

  • Voss, Jan Oliver;Dieke, Tobias;Doll, Christian;Sachse, Claudia;Nelson, Katja;Raguse, Jan-Dirk;Nahles, Susanne
    • Journal of Periodontal and Implant Science
    • /
    • 제46권2호
    • /
    • pp.72-83
    • /
    • 2016
  • Purpose: The goal of this study was to evaluate the long-term success of horizontal alveolar crest augmentation of the retromolar region of the mandible with particulated bone, as well as factors affecting subsequent peri-implant bone loss. Methods: A total of 109 patients (68 female, 41 male) suffering from alveolar ridge deficiencies of the maxilla and mandible were included in this study. All patients were treated with particulated retromolar bone grafts from the mandible prior to the insertion of endosseous dental implants. Mesial and distal peri-implant crestal bone changes were assessed at six time points. Several parameters, including implant survival and the influence of age, gender, localisation of the implant, diameter, covering procedures, and time points of implant placement, were analysed to identify associations with bone level changes using the Mann-Whitney U-test, the Kruskal-Wallis test, and Spearman's rank-order correlation coefficient. Results: A total of 164 dental implants were placed in the maxilla (n=97) and in the mandible (n=67). The mean observation period was $105.26{\pm}21.58$ months after implantation. The overall survival rate was 97.6% after 10 years. Overall, peri-implant bone loss was highest during the first year, but decreased over time. The mean amount of bone loss after 10 years was 2.47 mm mesially and 2.50 mm distally. Bone loss was significantly influenced by implant type and primary stability. Conclusions: The use of particulated autologous retromolar bone grafts is a reliable technique for the horizontal reconstruction of local alveolar ridge deficiencies. Our results demonstrate that implants placed in augmented bone demonstrated similar bone level changes compared to implants inserted in non-augmented regions.

Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

  • Alan, Raif;Marakoglu, Ismail;Haliloglu, Seyfullah
    • Journal of Periodontal and Implant Science
    • /
    • 제45권5호
    • /
    • pp.169-177
    • /
    • 2015
  • Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, $Aesthetica^{+2}$, Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.