• Title/Summary/Keyword: Peri implant fracture

Search Result 16, Processing Time 0.03 seconds

Management of peri-implantitis associated with tear-like implant fracture: case reports (열리형 임플란트 파절과 연관된 임플란트 주위염의 관리: 증례 보고)

  • Kim, Yeon-Tae;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.138-144
    • /
    • 2020
  • Implant fracture is rare, but one of the most serious problem in implantation. Treatment of implant fracture can be different according to the extent of the fracture and on the state of the surrounding prosthetic restoration. Maintaining or submerging implant after treatment of peri-implantitis can be useful options for cases of tear-like fracture on the coronal area of an implant.

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Fractures of implant fixtures: a retrospective clinical study

  • Yu, Han-Chang;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.13.1-13.6
    • /
    • 2020
  • Background: The aim of this study was to evaluate the factors that may affect implant fixture fractures. Methods: Patients who experienced implant fixture removal at Seoul National University Bundang Hospital from 2007 to 2015 due to implant fixture fracture were included. Implant/crown ratio, time of implant fracture, clinical symptoms before implant fracture, treatment of fractured implants, and the success and survival rate of the replaced implants were evaluated retrospectively. Results: Thirteen implants were fractured in 12 patients. Patient mean age at the time of fracture was 59.3 years. Of the 13 implants, 7 implants were placed at our hospital, and 6 were placed at a local clinic. The mean crown/implant ratio was 0.83:1. The clinical symptoms before fracture were screw loosening in five implants, marginal bone loss in five implants, and the presence of peri-implant diseases in five implants. All the fractured implants were removed, and 12 out of the 13 sites were re-implanted. Parafunctions were observed in two patients: one with bruxism and one with attrition due to a strong chewing habit. Conclusions: Several clinical symptoms before the fracture of an implant can predict implant fixture failure. Therefore, if these clinical symptoms are observed, appropriate treatments can be taken before more serious complications result.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Cha, Jae-Won;Kim, Eun-Ja;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.371-378
    • /
    • 2012
  • Many longitudinal studies have reported the successful osseointegration of dental implants, with survival rates approaching 90-95%. However, implants regarded as a "success" may have also failed to undergo osseointegration. A variety of complications and failures have been observed, including implant fracture - a rare and delayed biomechanical complication with serious clinical outcomes. Given the increasing popularity of dental implants, an increase in the number of failures due to late fractures is expected. This study sought to determine the rate of implant fractures and factors associated with its development. This retrospective evaluation analyzed implants placed at Wonkwang Dental Hospital (from 1996 to the present). In our study we found that the frequency of dental implant fractures was very low (0.23%, 8 implant fractures out of 3,500 implants placed). All observed fractures were associated with hybrid-surface threaded implants (with diameter of 4.0 or 3.75 mm). Prosthetic or abutment screw loosening preceded implant fracture in a majority of these cases.

Reconstruction of failed fixed implant prosthesis accompanied by abutment screw loosening and fracture : A case report (나사풀림과 나사파절이 동반된 실패한 임플란트 고정성 보철물의 회복증례)

  • Bae, Eun-Bin;Shin, Young-Gun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.55 no.7
    • /
    • pp.457-466
    • /
    • 2017
  • In the case of failed fixed implant prosthesis accompanied by abutment screw fracture, fractured screw fragment must be removed to use the existing implant fixtures. A 61-year-old male patient, who had a failed maxillary fixed implant prosthesis accompanied by three abutment screw fracture, hoped to reconstruct the maxillary implant prosthesis, while maintaining the existing implant fixtures. To use the existing implant fixtures, fractured screw fragments were removed. A maxillary implant overdenture using available existing implants was planned. Bar-attachment with Locator was used for implant splinting, denture stability, and retention. Final impression was taken after treatment of peri-implantitis. Jaw relation registration was taken to evaluate available interarch space for bar-attachment. After fabricating bar-attachment, centric relation was taken. Implant overdenture using bar-attachment with Locator was delivered after wax-denture evaluation. This case report showed that a satisfactory clinical result was achieved by implant overdenture using existing implant fixtures in a maxillary edentulous patient.

  • PDF

The prognosis of splinted restoration of the most-distal implants in the posterior region

  • Lee, Jong-Bin;Kim, Man-Yong;Kim, Chang-Sung;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.494-503
    • /
    • 2016
  • PURPOSE. The aim of this study was to compare the efficacies of two-implant splinting (2-IS) and single-implant restoration (1-IR) in the first and second molar regions over a mean functional loading period (FLP) of 40 months, and to propose the appropriate clinical considerations for the splinting technique. MATERIALS AND METHODS. The following clinical factors were examined in the 1-IR and 2-IS groups based on the total hospital records of the patients: sex, mean age, implant location, FLP, bone grafting, clinical crown-implant ratio, crown height space, and horizontal distance. The mechanical complications [i.e., screw loosening (SL), screw fracture, crown fracture, and repeated SL] and biological complications [i.e., peri-implant mucositis (PM) and peri-implantitis (PI)] were also evaluated for each patient. In analysis of two groups, the chi-square test and Student's t-test were used to identify the relationship between clinical factors and complication rates. The optimal cutoff value for the FLP based on complications was evaluated using receiver operating characteristics analysis. RESULTS. In total, 234 patients with 408 implants that had been placed during 2005 - 2014 were investigated. The incident rates of SL (P<.001), PM (P=.002), and PI (P=.046) differed significantly between the 1-IR and 2-IS groups. The FLP was the only meaningful clinical factor for mechanical and biological complication rates in 2-IS. CONCLUSION. The mechanical complication rates were lower for 2-IS than for 1-IR, while the biological complication rates were higher for 2-IS. FLP of 39.80 and 46.57 months were the reference follow-up periods for preventing biological and mechanical complications, respectively.

COMPLICATIONS ASSOCIATED WITH DENTAL IMPLANT SURGERY; CASE REPORT (임플란트 수술 시의 합병증; 증례 보고)

  • Lee, Hyun-Jin;Yeo, Duck-Sung;Lim, So-Yeon;An, Kyung-Mi;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • According to the increase in use of implants in clinical dentistry, new kinds of complications happen. Complications that can happen during implant placement are bleeding, nerve injury, jaw fracture, fenestration of maxillary sinus or nasal cavity, dehiscence, fenestration, injury of adjacent tooth. And complications that can happen after implant operation are infection, bleeding, hematoma, chronic sinusitis, peri-implantitis. Problems that are confronted during implant placement happen by inadequate preoperative treatment plan, inadequate consideration about individual anatomic difference, inadequate operation process and lack of experience of clinician. It is important that clinicians consider possible complications in advance and make a comprehensive treatment plan. We report the patient who was happened ramus fracture during block bone harvesting from ramus of severely atrophic mandible, the patient who came to emergency ward due to postoperative swelling and bleeding and the patient whose implant was migrated to maxillary sinus with a review of literature.

A retrospective study of the long-term survival of RESTORE® dental implants with resorbable blast media surface

  • Keun-Soo Ryoo;Pil-Jong Kim;Sungtae Kim;Young-Dan Cho;Young Ku
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.6
    • /
    • pp.444-452
    • /
    • 2023
  • Purpose: The aim of this study was to retrospectively evaluate the survival and failure rates of RESTORE® implants over a follow-up period of 10-15 years at a university dental hospital and to investigate the factors affecting the survival rate of these dental implants. Methods: A total of 247 RESTORE® dental implants with a resorbable blast media (RBM) surface inserted in 86 patients between March 2006 and April 2011 at the Department of Periodontology of Seoul National University Dental Hospital were included. Patients with follow-up periods of less than 10 years were excluded, and data analysis was conducted based on dental records and radiographs. Results: Over a 10- to 15-year period, the cumulative survival rate of the implants was 92.5%. Seventeen implants (6.88%) were explanted due to implant fracture (n=10, 4.05%), peri-implantitis (n=6, 2.43%), and screw fracture (n=1, 0.4%). The results of univariate regression analysis using a Cox proportional hazards model demonstrated that implants placed in male patients (hazard ratio [HR], 4.542; 95% confidence interval [CI], 1.305-15.807; P=0.017) and implants that supported removable prostheses (HR, 15.498; 95% CI, 3.105-77.357; P=0.001) showed statistically significant associations with implant failure. Conclusions: Within the limitations of this retrospective study, the RESTORE® dental implant with an RBM surface has a favorable survival rate with stable clinical outcomes.

Immediate implant placement and provisionalization of single implant in the esthetic region : Cases report (심미적 영역에서 즉시 임플란트 식립 및 임시 수복을 통한 단일치의 수복에 대한 증례 보고)

  • Lee, Song-Bea;Park, Yu-Seon;Kim, Byoung-Heon;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of the Korean dental association
    • /
    • v.58 no.2
    • /
    • pp.83-92
    • /
    • 2020
  • In the anterior maxillary area, dental implants for tooth replacement are challenging due to the need to satisfy high esthetic level as well as functionality. Immediate implant placement and provisionalization can dramatically reduce the edentulous period, and then fulfill patient's demand for esthetics. The aim of present case report is to demonstrate two cases that successfully restored single tooth with immediate implant placement and provisionalization in the anterior maxillary area. A 47 years old female was scheduled to replace her maxillary right central incisor due to crown-root fracture by trauma. Another 54-year-old female was planned to place dental implant following tooth extraction of maxillary right lateral incisor owing to continuous pus discharge despite repetitive treatments including apicoectomy. In these two cases, surgical and prosthetic procedures progressed in a similar way. After minimal flap elevation, atraumatic tooth extraction was performed. Implant was placed in proper 3-dimensional position and angulation with primary stability. Bone graft or guided bone regeneration for peri-implant bone defect was conducted simultaneously. Provisionalization without occlusal loading was carried out at the same day. Each definitive crown was delivered at 7 and 5 months after the surgery. Two cases have been followed uneventfully for 2 to 5 years of loading time. In conclusion, Immediate implant placement and provisionalization could lead to esthetic outcome for single tooth replacement with dental implant under proper case selection.

  • PDF