• Title/Summary/Keyword: Perfusion scan

Search Result 136, Processing Time 0.028 seconds

Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas (두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성)

  • Oh, Shin-Hyun;Roh, Dong-Wook;Ahn, Sha-Ron;Park, Hoon-Hee;Lee, Seung-Jae;Kang, Chun-Goo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: There are various methods to diagnose hemangioma, such as ultrasonography (US), computed tomography (CT), magnetic resonance imaging (MRI) and nuclear medicine. However, by development of SPECT imaging, the blood-pool scan using $^{99m}Tc$-labeled red blood cell has been used, because it was non-invasive and the most economical method. Therefore, in this study, we proposed that the usefulness of $^{99m}Tc$-RBC scan and SPECT of the head and neck to diagnose unlocated hemangiomas. Materials and Methods: $^{99m}Tc$-RBC scan and SPECT was performed on 6 patients with doubtful hemangioma (4 person, head; 1 person, neck; 1 person, another). We labeled radiopharmaceutical using modified in vivo method and then, centrifuged it to remove plasma. After a bolus injection of tracer, dynamic perfusion flow images were acquired. Then, anterior, posterior, both lateral static blood-pool images were obtained as early and 4 hours delayed. SPECT was progressed 64 projections per 30 seconds. Each image was interpreted by physicians, Nuclear medicine specialist, and technologist blinded to patient's data. Results: In 5 patients of all the radioactivity of doubtful site didn't change in flow images, but, in blood-pool, delayed and SPECT images, it was increased. So, it was a typical hemangioma finding. The size of lesion was over 2 cm, and it could discriminate as comparing to the delayed and SPECT imaging. On the other hand, in 1 patient, the radioactivity was increased in blood-pool images, but, not in delayed and SPECT images, so, it was proved no hemangioma. Conclusion: Using $^{99m}Tc$-RBC Scan and SPECT, we could diagnose the hemangiomas in head and neck, as well as, liver, more non-invasive, economical, and easy. Therefore, it considered that $^{99m}Tc$-RBC scan and SPECT would offer more useful information for diagnosis of hemangioma, rather than otherimaging such as US, CT, MRI.

  • PDF

A Study on the Measurement of Intrapulmonary Shunt in Liver Diseases by the Nucleotide Method (핵의학적 방법에 의한 간질환자(肝疾患者)의 폐장내 단락양 측정에 관한 연구)

  • Yun, Sung-Chul;Ahn, Jae-Hee;Choi, Soo-Bong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.199-205
    • /
    • 1987
  • The fact there are increase of intrapulmonary arterioveneous shunt amount in the liver cirrhosis patient has been known since 1950. And the method of shunt amount calculation by radionuclide method using $^{99m}Tc-MAA$ was introduced in the middle of 1970. We measured intrapulmonary shunt amount by means of perfusion lung scan using $^{99m}Tc-MAA$ in the various type of liver diseases especially in chronic liver diseases and acute liver disease. The results were as followed. 1) The amount of arteriovenous intrapulmonary shunt in the total case of liver disease was $9.3{\pm}3.9%$, and that of in the control group was $4.6{\pm}2.1%$. 2) The amount of arteriovenous intrapulmonary shunt in the chronic liver disease was $10.8{\pm}4.4%$, and that of in the acute liver disease was $7.2{\pm}2.8%$. We observed significant differences between normal control group and liver disease group, and between chronic liver disease group and acute liver disease group in the amount of shunt by the nucleolide method.

  • PDF

Fast MRI in Acute Ischemic Stroke: Applications of MRI Acceleration Techniques for MR-Based Comprehensive Stroke Imaging

  • You, Sung-Hye;Kim, Byungjun;Kim, Bo Kyu;Park, Sang Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.2
    • /
    • pp.81-92
    • /
    • 2021
  • The role of neuroimaging in patients with acute ischemic stroke has been gradually increasing. The ultimate goal of stroke imaging is to make a streamlined imaging workflow for safe and efficient treatment based on optimized patient selection. In the era of multimodal comprehensive imaging in strokes, imaging based on computed tomography (CT) has been preferred for use in acute ischemic stroke, because, despite the unique strengths of magnetic resonance imaging (MRI), MRI has a longer scan duration than does CT-based imaging. However, recent improvements, such as multicoil technology and novel MRI acceleration techniques, including parallel imaging, simultaneous multi-section imaging, and compressed sensing, highlight the potential of comprehensive MR-based imaging for strokes. In this review, we discuss the role of stroke imaging in acute ischemic stroke management, as well as the strengths and limitations of MR-based imaging. Given these concepts, we review the current MR acceleration techniques that could be applied to stroke imaging and provide an overview of the previous research on each essential sequence: diffusion-weighted imaging, gradient-echo, fluid-attenuated inversion recovery, contrast-enhanced MR angiography, and MR perfusion imaging.

Hydrogen Sulfide Poisoning (황화수소 중독 증례)

  • Choi, Young-Hee;Nam, Byung-Kuk;Kim, Hyo-Kyung;Park, Ji-Kang;Hong, Eun-Seog;Kim, Yang-Ho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.1
    • /
    • pp.31-36
    • /
    • 2004
  • Three workers, field operators in lubricating oil processing of petroleum refinery industry were found unconscious by other worker. One of them who were exposed to an high concentration of H2S was presented with Glasgow Coma Score of 5, severe hypoxemia on arterial blood gas analysis, normal chest radiography, and normal blood pressure. On hospital day 7, his mental state became clear, and neurologic examination showed quadriparesis, profound spasticity, increased tendon reflexes, abnormal Babinski response, and bradykinesia. He was also found to have decreased memory, attention deficits and blunted affect which suggest general cognitive dysfunction, which improved soon. MRI scan showed abnormal signals in both basal ganglia and motor cortex, compatible with clinical findings of motor dysfunction. Neuropsychologic testing showed deficits of cognitive functions. SPECT showed markedly decreased cortical perfusion in frontotemporoparietal area with deep white matter. Another case was recovered completely, but the other expired the next day.

  • PDF

Perfusion Impairment in Infantile Autism on Brain SPECT Using Tc-99m ECD : Comparison with MR Findings (유아 자폐증 환아에서의 Tc-99m ECD를 이용한 뇌 단일 광전자 방출 전산화 단층 촬영술상의 관류 저하: 자기 공명 영상과의 비교 분석)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Yoon, Pyeong-Ho;Kim, Dong-Ik;Oh, Young-Taik;Lee, Sun-Ah;Lee, Ho-Bun;Shin, Yee-Jin;Lee, Byung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.320-329
    • /
    • 1997
  • Neuroanatomic substrate of autism has been the subjects of continuing investigation. Because previous studies had not demonstrated consistent and specific neuroimaging findings in autism and most studies comprised adults and school-aged children, we performed a retrospective review in search of common functional and anatomical abnormalities with brain SPECT using Tc-99m ECD and correlative MRI The patient population was composed of 18 children aged 28 to 89 months(mean age : 55 months) who met the diagnostic criteria of autism as defined in the DSM-IV and CARS. Brain SPECT was performed after intravenous injection of 185-370MBq of Tc-99m ECD using brain dedicated annular crystal gamma camera. MRI was performed in all patients including T1, T2 axial and T1 sagittal sequences. SPECT data were visually assessed. Thirteen patients had abnormal SPECT scan revealing focal areas of decreased perfusion. Decreased perfusion of cerebellar vermis(12/18), cerebellar hemisphere(11/18), thalami(13/18), basal ganglia(4/18), posterior parietal(7/18), and temporal(4/18) area were noted on brain SPECT. Whereas, only 3 patients had abnormal MR findings which were subtle volume loss of parieto-occipital white matter in 3 and mild thinning of posterior body of corpus callosum in 2 and slightly decreased volume of cerebellar vermis in 1. Comparison of the numbers of abnormal findings revealed that regional cerebral blood flow (rCBF) abnormalities seen on SPECT were more numerous than anatomical abnormalities seen on MRI. In conclusion, extensive perfusion impairment involving cerebellum, thalami and parietal lobe were found in this study. SPECT may be more sensitive in reflecting pathophysiology of autism than MRI. However, further studies are mandatory to determine the significance of thalamic and parietal perfusion impairment in autism.

  • PDF

Feasibility of Reflecting Improvement of Tumor Hypoxia by Mild Hyperthermia in Experimental Mouse Tumors with $^18F-Fluoromisonidazole$ (저온온열치료에 의한 종양 내 저산소상태 개선효과를 $^18F$-Fluoromisonidazole의 섭취 변화를 이용한 평가)

  • Lee Sang-wook;Ryu Jin Sook;Oh Seung Joon;Im Ki Chun;Chen Gi Jeong;Lee So Ryung;Song Do Young;Im Soo Jeong;Moon Eun Sook;Kim Jong Hoon;Ahn Seung Do;Shin Seong Soo;Lee Kyeong Ryong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.288-297
    • /
    • 2004
  • Puporse: The aims of this study were to evaluate the change of $[^18F]fluoromisonidazole$($[^18F]FMISO$) uptake in C3H mouse squamous cell carcinoma-VII (SCC-VII) treated with mild hyperthermia ($42^{circ}C$) and nicotinamide and to assess the biodistribution of the markers in normal tissues under similar conditions. Methods and Materials: $[^18F]FMISO$ was producedby our hospital. Female C3H mice with a C3H SCC-VII tumor grown on their extremities were used. Tumors were size matched. Non-anaesthetized, tumor-bearing mice underwent control or mild hyperthermia at $42^{circ}C$ for 60 min with nicotinamide (50 mg/kg i.p. injected) and were examined by gamma counter, autoradiography and animal PET scan 3 hours after tracer i.v. injected with breathing room air, The biodistribution of these agents were obtained at 3 h after $[^18F]FMISO$ injection. Blood, tumor, muscle, heart, lung, liver, kidney, brain, bone, spleen, and intestine were removed, counted for radioactivity and weighed. The tumor and liver were frozen and cut with a cryomicrotome into 10- um sections. The spatial distribution of radioactivity from the tissue sections was determined with digital autoradiography. Results: The mild hyperthermia with nicotinamide treatment had only slight effects on the biodistribution of either marker in normal tissues. We observed that the whole tumor radioactivity uptake ratios were higher in the control mice than in the mild hyperthermia with nicotinamide treated mice for $[^18F]FMISO$ ($1.56{\pm}1.03$ vs. $0.67{\pm}0.30$; p=0.063). In addition, autoradiography and animal PET scan demonstrated that the area and intensity of $[^18F]FMISO$ uptake was significantly decreased. Conclusion: Mild hyperthermla and nicotinamide significantly improved tumor hypoxia using $[^18F]FMISO$ and this uptake reflected tumor hypoxic status.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Diagnostic Ability of Tc-99m MIBI SPECT in Coronary Artery Diseases is not Affected by the Degree of Exercise (운동 정도와 무관한 Tc-99m Methoxyisobutyl Isonitrile 심근관류 스캔의 진단능)

  • Lee, Jae-Tae;Kim, Jong-Soo;Chun, Kyung-Ah;Lee, Sang-Woo;Kang, Do-Young;Cho, Yong-Keun;Chae, Shung-Chull;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.40-48
    • /
    • 1999
  • Purpose: The sensitivity of ST-depression in the electrocardiogram during exercise is influenced by the level of efforts. However, unlike the prevalence of ST-depression on exercise ECG, the degree of exercise is reported to do not influence the diagnostic ability of myocardial perfusion scan. Furthermore, the relation between the prevalence of myocardial ischemia and effort is still controversial. We evaluated the effect of the degree of exercise on the ability of SPECT imaging to detect coronary artery stenosis. Materials and Methods: The patient population was comprised of 111 patients (73 men and 38 women, mean age 56 years) who underwent an exercise test in conjunction with Tc-99m MIBI and cardiac catheterization within 3 months apart each other. The degree of exercise was classified into four groups according to the percentage of maximal predicted heart rate. The sensitivity and specificity was compared between each group. Results: The overall diagnostic sensitivity was significantly higher with Tc-99m MIBI SPECT than exercise ECG. The specificity was not significantly different between two tests. Sensitivity and specificity of Tc-99m MIBI was not different between four groups. Sensitivity for individual coronary stenosis seemed to be lower in subjects who had premature termination of exercise due to early appearance of ST depression. Conclusion: These results suggest that the overall diagnostic sensitivity of Tc-99m MIBI myocardial perfusion SPECT is not significantly affected by the degree of exercise in stable patients undergoing symptom-limited treadmill exercise testing. Myocardial perfusion SPECT imaging should be added to routine exercise stress testing for the detection of coronary artery disease.

  • PDF

Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$ ($^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교-)

  • Bom, Hee-Seung;Kim, Ji-Yeul;Park, Joo-Hyung;Ahn, Young-Keun;Jeong, Myung-Ho;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF