• 제목/요약/키워드: Perfusion MR imaging

검색결과 75건 처리시간 0.03초

고 자장 기능적 MR 영상을 이용한 뇌 운동 영역에서 산소 주입에 따른 활성화 영역에 관한 연구 (Cerebral Activation Area Following Oxygen Administration using a 3 Tesla Functional MR Imaging)

  • 구은회;권대철
    • 대한인간공학회지
    • /
    • 제24권4호
    • /
    • pp.47-53
    • /
    • 2005
  • This study aim to investigate the effects of supply of oxygen enhances cerebral activation through increased activation in the brain and using a 3 Tesla fMRI system. Five volunteers (right handed, average age of 21.3) were selected as subjects for this study. Oxygen supply equipment that provides 30% oxygen at a constant rate of 15L/min was given using face mask. A 3 Tesla fMRI system using the EPI BOLD technique, and three-pulse sequence technique get of the true axial planes scanned brain images. The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other. Both task consisted of 96 phases including 6 activations and rests contents. Post-processing was done on MRDx software program by using cross-correlation method. The result shows that there was an improvement in performance and also increased activation in several areas in the oxygen method. These finding demonstrates that while performing cognitive tasks, oxygen administration was due to increase of cerebral activation.

간혈관종의 조영증강속도와 복셀내비결집운동 MR영상과의 상관관계 (Correlation of the Speed of Enhancement of Hepatic Hemangiomas with Intravoxel Incoherent Motion MR Imaging)

  • 양달모;장건호;김현철;김상원;김혁기
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권3호
    • /
    • pp.208-218
    • /
    • 2014
  • 목적: 조영증강 MRI에서의 간혈관종의 조영증강속도와 겉보기확산계수 및 복셀내비결집운동 MR영상에서의 여러가지 지표인, 진성 확산계수 (D), 관류계수 (f), 가성 확산계수 ($D^*$), 겉보기확산계수 ($ADC_{fit}$)와의 상관관계를 알아보고자 하였다. 대상과 방법: 후향적인 연구로 IRB 승인을 받았다. 39명 환자에서 47개의 간혈관종을 연구대상으로 하였다. 이 중 남자가 20명 여자가 19명이었다. 간혈관종은 조영증강후 시행한 T1 강조영상에서의 조영증강 속도에 따라서 3가지 형으로 분류하였고, 빠른 조영증강을 보이는 간혈관종은 A형, 중간정도는 B형, 느린 조영증강을 보이는 경우는 C형으로 하였다. D, f, $D^*$ and $ADC_{fit}$ 값을 구하여 3가지형의 간혈관종 간에 차이를 비교하였다. 결과: $ADC_{fit}$와 D 값은 C형의 간혈관종이 A형의 간혈관종보다 유의하게 낮았다 (P = 0.0022, P = 0.0085). 하지만 f 와 $D^*$ 값은 세 군간에 차이가 없었다. 모든 b값에서의 (50, 200, 500 and $800sec/mm^2$) 겉보기확산계수값은 C형이 A형에 비해 유의하게 낮았다 (P < 0.012). 그리고 b값이 $800sec/mm^2$에서 C형의 겉보기확산계수 값이 B형보다 유의하게 낮았다 (P = 0.0021). 하지만 다른 b 값에서는 A형과 B형, B형과 C형 간의 차이는 없었다(P > 0.016). 간혈관종의 조영증강 속도와 각 b 값에서의 겉보기확산계수 값 $ADC_{50}$ (${\rho}=-0.357$, P = 0.014), $ADC_{200}$ (${\rho}=-0.537$, P = 0.0001), $ADC_{500}$ (${\rho}=-0.614$, P = 0.0001), $ADC_{800}$ (${\rho}=-0.607$, P = 0.0001)과는 부적 상관관계 (negative correlation)를 보였다. 따라서 $ADC_{50}$, $ADC_{200}$, $ADC_{500}$, and $ADC_{800}$에서의 겉보기확산계수 값은 조영증강속도가 느릴수록 감소하는 경향을 보였다. 결론: 간혈관종은 조영증강 속도에 따라 다양한 겉보기확산계수 값을 보이고, 느린 조영증강을 보이는 간혈관종이 감소된 겉보기확산계수 값을 보이는 것은 진성 분자확산과 관계가 있다.

뇌경색 환자에서 뇌종양과 유사한 Tc-99m tetrofosmin의 섭취 (Cerebral Infarction Mimicking Brain Tumor on Tc-99m Tetrofosmin Brain SPECT imaging)

  • 김순;전석길;원경숙
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.268-271
    • /
    • 2004
  • A 43-year-old man was presented with persistent headache for two weeks. 72 weighted MR imaging showed high signal intensity with surrounding edema in the left frontal lobe. These findings were considered with intracranial tumor such as glioma or metastasis. Tc-99m tetrofosmin SPECT showed focal radiotracer accumulation in the left frontal lobe. The operative specimen contained cerebral infarction with organizing leptomeningeal hematoma by pathologist. Another 73-year-old man was hospitalized for chronic headache. Initial CT showed ill-defined hypodensity with mass effect in the right parietal lobe. Tc-99m tetrofosmin SPECT showed focal radiotracer uptake in the right parietal lobe. These findings were considered with low-grade glioma or infarction. Follow-up CT after 5 months showed slightly decreased in size of low density in the right parietal lobe, and cerebral infarction is more likely than others. Tc-99m tetrofosmin has been proposed as a cardiotracer of myocardial perfusion imaging and an oncotropic radiotracer. Tc-99m tetrofosmin SPECT image provides a better attractive alternative agent than T1-201 as a tumor-imaging agent, with characteristics such as high-energy flux, short half-life, favorable biodistribution, dosimetry and lower background radioactivity. We have keep in mind on the analysis of Tc-99m tetrofomin imaging when cerebral infarction is being differentiated from brain tumor.

조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법 (MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.73-82
    • /
    • 1998
  • 목적 : 간특정 MR 조영제를 이요하여 간세포의 세포막을 통한 물분자의 교환 및 세포막 투과율을 정확히 측정 할 수 있는 MR 기법을 개발하고자 하였다. 대상 및 방법 : 쥐의 간세포를 분리하여 낸 후 NMR 측정을 시도하엿다. 모든 실험은 0.02MHz부터 60 MHz까지 양성자의 Larmor 주파수를 변화시킬 수 있는 IBM형 field cycling relaxometer를 사용하여 시행하였으며 spin-echo 펄스열을 사용하여 T1 자기이완시간을 측정하였다. 전오도의 간특정 조영제인 Gd-EOB-DTPA를 함유하고 있는 간세포 샘플로부터 획득한 T1 데이터를 연속분포 분석법을 사용하여 분석하였으며 이때 이론적 모델로는 Two compartmental exchange 모델을 이용하였다. 결과 : 간세포내의 물분자의 평균 거주시간은 약 250 msec이며 간세포막의 투과율에 대한 최저치는 $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$ 이었다. 자기이완시간의 연속적인 분포도를 구할 수 있는 CONTIN 분석기법을 적용한 결과 확산적 물분자 교환이 일어남을 밝혔고 이러한 확산적 교환의 정도가 간세포의 경우 세포내 공간에서는 작지 않다는 사실을 규명 할 수 있었다. 결론 : 연속분포 분석기법을 적용하는 경우 Gd-EOB-DTPA는 간세포에서의 물분자의 교환정도 및 세포막의 물분자에 대한 투과율을 측정하는데 매우 유용한 방법임을 확인하였고 간세포에서의 물분자의 교환속도는 적혈구에서의 물분자 교환 속도에 비해 매우 느리다는 사실을 확인하였다. 따라서 조직 특정 조영제는 해당 조직 혹은 세포의 세포막 투과율과 같은 생리학적 정보를 알아낼 수 있는 기능적 조영제로서의 유용성을 입증할 수 있었다.

  • PDF

고 자장에서 Dynamic Susceptibility Contrast 효과에 관한 연구 : Gradient EPI와 Spin-EPI기법의 비교 (A Study on Dynamic Susceptibility-weighted Perfusion MR Imaging at High Magnetic Filed : Comparison of Gradient Echo-EPI and Spin Echo-EPI)

  • 구은회;채홍인;박종배;임청환;김정구
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.11-16
    • /
    • 2007
  • We have evaluated and compared of gradient echo and spin echo EPI for compensating about deeply distortion aspect in case of post-operation patients in magnetic resonance image. A total of 100 patients were performed on 3.0 T(GE Signa Excite E2, USA) with 8ch head coil. As a result of analysis, The SNRs of whiter and gray matter areas were 36.74 $\pm$ 06 and 39.96 $\pm$ 09 in the gradient echo EPI, the SNRs which white and gray matter areas were slightly higher than gradient echo EPI(P<0.005, paired student t-test). It was 46.24 $\pm$ 11 and 51.38 $\pm$ 13 in gradient and spin echo EPI, respectively. The signal intensity in the whiter and gray matter areas also were 87.33 $\pm$ 15.24 and 140.66 $\pm$ 13.45 in the gradient echo EPI techniques, The signal intensity of gradient echo EPI showed higher values compared to spin echo EPI. Otherwise, gradient echo EPI technique is distortion enough to operation wound and edge of the image, while spin echo EPI technique did not appear almost. In this point, the spin echo EPI technique, after surgical operation according to patient state beside gradient echo EPI techniques that signalbeside gradient echo EPI techniques that signal intensity is high and patient's case which image distortion is serious by metal etc, will be provide the useful information in adults and pediatric patients.

  • PDF

Prognostic Prediction Based on Dynamic Contrast-Enhanced MRI and Dynamic Susceptibility Contrast-Enhanced MRI Parameters from Non-Enhancing, T2-High-Signal-Intensity Lesions in Patients with Glioblastoma

  • Sang Won Jo;Seung Hong Choi;Eun Jung Lee;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1369-1378
    • /
    • 2021
  • Objective: Few attempts have been made to investigate the prognostic value of dynamic contrast-enhanced (DCE) MRI or dynamic susceptibility contrast (DSC) MRI of non-enhancing, T2-high-signal-intensity (T2-HSI) lesions of glioblastoma multiforme (GBM) in newly diagnosed patients. This study aimed to investigate the prognostic values of DCE MRI and DSC MRI parameters from non-enhancing, T2-HSI lesions of GBM. Materials and Methods: A total of 76 patients with GBM who underwent preoperative DCE MRI and DSC MRI and standard treatment were retrospectively included. Six months after surgery, the patients were categorized into early progression (n = 15) and non-early progression (n = 61) groups. We extracted and analyzed the permeability and perfusion parameters of both modalities for the non-enhancing, T2-HSI lesions of the tumors. The optimal percentiles of the respective parameters obtained from cumulative histograms were determined using receiver operating characteristic (ROC) curve and univariable Cox regression analyses. The results were compared using multivariable Cox proportional hazards regression analysis of progression-free survival. Results: The 95th percentile value (PV) of Ktrans, mean Ktrans, and median Ve were significant predictors of early progression as identified by the ROC curve analysis (area under the ROC curve [AUC] = 0.704, p = 0.005; AUC = 0.684, p = 0.021; and AUC = 0.670, p = 0.0325, respectively). Univariable Cox regression analysis of the above three parametric values showed that the 95th PV of Ktrans and the mean Ktrans were significant predictors of early progression (hazard ratio [HR] = 1.06, p = 0.009; HR = 1.25, p = 0.017, respectively). Multivariable Cox regression analysis, which also incorporated clinical parameters, revealed that the 95th PV of Ktrans was the sole significant independent predictor of early progression (HR = 1.062, p < 0.009). Conclusion: The 95th PV of Ktrans from the non-enhancing, T2-HSI lesions of GBM is a potential prognostic marker for disease progression.

뇌영역의 동적 자화율 대조도 영상에서 Gd-DTPA 조영제의 비투과성 조사: 새로운 비선형 곡선조화 알고리즘 개발의 예비연구 (Assessment of Non-permeability of Gd-DTPA for Dynamic Susceptibility Contrast in Human Brain: A Preliminary Study Using Non-linear Curve Fitting)

  • 윤성익;장건호;강현수;김영주;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.103-109
    • /
    • 2007
  • 목적: 정상인의 뇌영역의 동적 자화율 대조도 (dynamic susceptibility contrast)에서 새로운 비선형 곡선조화 알고리즘을 사용한 Gd-DTPA의 비투과성 (non-permeability)을 조사하고자 한다. 대상 및 방법: 전반적인 혈관내의 이동에 대한 전달함수($K^{trans}$)에 대하여 첫 번째 통과된 조합변수인자의 화소에 대한 정량적인 분석을 실시하였다. 정확한 복셀값의 산출을 위하여 개선된 알고리즘에 의한 경계값을 적용하여 최적화 과정을 반복수행하였다. 결과: 비선형 곡선조화 알고리즘을 적용함으로서, 뇌혈류와 뇌혈류량 측정은 $T2^*$-강조 dynamic contrast enhanced (DCE)에서 상당히 개선 되었다. 재산출된 인자들로부터 뇌관류 강조영상의 형성은 수정된 비선형 곡선조화 알고리즘을 사용하여 획득하였다. 가상공간의 계산과 데이터 입력은 $T2^*$-강조 DCE 영상에서 조영제 포화도를 산출하였다. 결론: 본 연구에서 개발한 새로운 비선형 곡선조화 알고리즘을 사용하여 DCE-$T2^*$ 강조 자기공명영상 데이터를 얻은 후에 역동학적 인자들의 정확성 및 효율성을 개선시키는데 도움을 주는 것으로 확인되었다.

  • PDF

뇌교종의 악성도 평가에서의 관류자기공명영상의 유용성에 관한 연구 (A Study on the Usefulness of Perfusion MRI in Grading of Gliomas)

  • 강현수;김종만;고신관;문찬홍;유인규;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.461-469
    • /
    • 2009
  • 최근 신경계 질환의 진단에 많이 이용되는 관류자기공명영상기법 중 상대적 뇌 혈류량(relative cerebral blood volume)의 분석에 의한 뇌교종의 악성도 구분(고등급과 저등급 종양의 구분)에 있어 자기공명영상의 뇌 혈류량 검사의 유용성에 대하여 알아보고자 하였다. 뇌교종 환자 17명(평균연령 57.5세, 남자 11명, 여자 6명)을 대상으로 모든 환자에게 수술 전 관류자기공명 영상과 고식적 뇌 자기공명영상을 시행하고, 조직의 병리학적 검사를 시행하였다. 국소적 뇌 혈류량과 상대적 뇌 혈류량의 분석은 지멘스사의 소프트웨어(PAT)와 자체 개발한 영상 후 처리 소프트웨어 Xmap 2.0을 이용하여 비교, 분석하였다. 대상자 17명 중 뇌교종이 저등급인 6명과 고등급인 11명의 관류자기공명영상의 분석 결과는 저등급 뇌교종의 상대적 뇌 혈류량의 백질에 대한 종양부위의 평균 뇌 혈류량(rCBVw)의 평균은 1.62, 피질에 대한 종양부위의 평균 뇌 혈류량(rCBVc)의 평균은 0.12이었다. 고등급 뇌교종의 상대적 뇌 혈류량의 rCBVw의 평균은 33.53, rCBVc의 평균은 0.96이었다. 뇌교종과 반대측 뇌 백질과의 통계적인 상관성은 0.01(p-value)이었고. 뇌교종과 반대측 피질과의 통계적인 상관성은 0.02(p-value)로 나타났다. 결과 중 뇌교종과 뇌 백질의 통계분석수치가 뇌교종과 피질과의 통계분석 결과보다 더 유의한 결과를 나타내었다. 결국 두 가지 모두에서 유의한 결과를 나타냄을 알 수 있었다(p<0.05). 임상적으로 기존의 자기공명영상과 병리학적 결과와 함께 관류자기공명영상은 뇌교종의 등급을 판단하는데 있어 유용할 것으로 사료된다.

  • PDF

장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교 (Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols)

  • 고정민;정정임;이배영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.83-90
    • /
    • 2013
  • 목적: 본 연구의 목적은 환자에서 임상적으로 사용되는 영상 프로토콜을 이용하여 시행된 3.0 T 심장자기공명영상을 1.5 T 와 비교하여 그 유용성을 알아보고자 하는데 있다. 대상과 방법: 10개월간 30명의 환자에서 얻은 1.5 T 자기공명영상과 20명의 3.0 T 영상을 후향적으로 비교하였다. 각각의 영상에 대하여 신호 대 잡음비 (signal-to-noise ratio: SNR), 대조도 대 잡음비 (contrast-to-noise ratio: CNR), 영상 화질 (artifact의 정도에 따라서 5단계로 분류)을 평가하고 비교하였다. 결과: T1심장 형태 영상 및 심근 생존능 평가 영상에서는 3.0 T 자기공명영상에서 영상화질 (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p=0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p=0.744; 지연기 조영 증강 영상: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p=0.254)의 유의한 저하 없이 SNR과 CNR의 향상을 보였다 (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p=0.068, CNR 18%, p=0.059; 지연기 조영 증강 영상: SNR 45%, p=0.017, CNR 37%, p=0.135). 심장Cine 영상에서 3.0 T 심장영상이 1.5 T 영상과 비교하여 영상화질($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001)이 다소 떨어졌으나 SNR과 CNR의 유의한 상승을 보였다 (SNR 143% 상승, CNR 108% 상승, p < 0.001). 심근관류영상에서는 SNR (11% 감소, p=0.172)과 CNR (7% 감소, p=0.638) 이 통계적으로 유의하지 않은 정도로 감소되었으나 영상화질($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p=0.006)은 유의한 향상을 보였다. 결론: 실제 임상영역에서 사용되는 영상 프로토콜로 시행된 3.0 T 심장자기공명영상은 1.5T 영상과 비교하여 충분한 영상의 질을 제공하였다.

급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교 (Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT)

  • 김혜선;박동우;김용수;김영선;최요원;전석철;서흥석;함창곡;김순길;안유헌;최윤영;박충기
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.100-107
    • /
    • 2003
  • 목적 : 급성심근경색을 진단하는데 있어 심장자기공명영상의 유용성을 알아보고, 생존심근을 평가하는데 있어 Tl-201 심근관류 SPECT와 비교하고자 하였다. 대상 및 방법 : 흉통 및 호흡곤란이 있는 환자 중 심장자기공명영상과 Tl-201 SPECT를 시행한 17명을 후향적으로 조사하였다. 심장자기공명영상에서는 T2강조영상에서 심벽의 고신호 강도 유무, 영화영상에서 심벽 운동, Gd-DTPA 조영 증강 후 좌심실 벽의 관류 결손 및 주입 15분 후의 지연조영증강 유무를 평가하였다. T1-201 SPECT에서는 아데노신 부하 영상과 휴식기 영상을 얻어 관류 결손 유무와 관류 결손시 가역성 여부를 평가하였다. 결과 심장자기공명영상과 T1-201 SPECT 모두 급성심근경색을 진단하는데 통계적으로 의미가 있었고, T2강조영상, T1-201 SPECT, 지연조영증강 및 심벽운동 순으로 연관성이 있는 것으로 나타났고, 관류 결손은 통계적 유의성이 없었다. 생존심근 평가에 있어서는 두 검사간 유의한 차이가 없었으며, T2강조영상과 관류영상에서 T1-201 SPECT와 높은 일치율, 지연조영증강 및 심벽운동은 낮은 일치율을 보였다. 결론 : 심장자기공명영상은 급성심근경색을 진단하는데 매우 유의한 진단율을 보였고, 생존 심근여부의 판단에 있어 SPECT와 높은 일치율을 보였다. 그러나 각 검사별 판독 기준과 방법에서 많은 연구가 필요할 것으로 생각된다.

  • PDF