• Title/Summary/Keyword: Perfusion CT

Search Result 107, Processing Time 0.036 seconds

The Usefulness of Deconvolution Perfusion CT in Patients with Acute Cerebral Infarction : Comparison with Diffusion MRI (급성 뇌경색 환자에서 Deconvolution perfusion CT의 유용성 : Diffusion MRI와 비교)

  • Eun, Sung-Jong;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.25-31
    • /
    • 2003
  • This study was performed to evaluate the usefulness of Deconvolution perfusion CT in patients with acute cerebral infarction. Nine patients with acute cerebral infarction underwent conventional CT and cerebral perfusion CT within 23 hours of the onset of symptoms. The perfusion CT scan for each patient was obtained at the levels of basal ganglia and 1cm caudal to the basal ganglia. By special imaging software, perfusion images including cerebral blood volume(CBV), cerebral blood flow(CBF), and mean transit time(MTT) maps were created. The created lesions were evaluated on each perfusion maps by 3 radiolocical technician. MTT delay time was measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Lesion sire were measured on each perfusion map and compared with the value obtained by diffusion weighted MR imaging(DWMRI). All perfusion CT maps showed the perfusion defect lesion in all patients. There were remarkable CT delay in perfusion defect lesion. In comparison of lesion size between each perfusion map and DWMRI, the lesion on CBF map was the most closely correlated with the lesion on DWMRI(7/9). The size of perfusion defect lesion on MTT map was larger than that of lesion on DWMRI, suggesting that m map can evaluate the ischemic penumbra. Deconvolution Perfusion CT maps make it possible to evaluate not only ischemic core and ischemic penumbra but also hemodynamic status in perfusion defect area. These results demonstrate that perfusion CT can be useful to the diagnosis and treatment in the patients with acute cerebral ischemic infarction.

  • PDF

The functional imaging to Diagnose Acute Cerebral infarction Comparing between CT Perfusion and MR Diffusion Imaging (급성 뇌경색 진단을 위한 CT관류영상과 MR확산영상의 비교)

  • Kim, Seon-Hee;Eun, Sung-Jong;Rim, Chae-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • It is very important for early diagnosis and therapy with ischamic cerebral infarction patients. This study was to know the ischemic penumbra lesion which compared CT-perfusion and diffusion weighted MRI(DWMRI) with acute cerebral infarction patients. 12 acute cerebral infarction patients had performed perfusion CT and performed DWMRI. Perfusion images including cerebral blood volume(CBV), cerebral blood flow(CBF), time to peak(TTP) and mean transit time(MTT) maps obtained the values with defect lesion and contralateral normal cerebral hemisphere and DWMRI was measured by signal intensity and compared of lesion size between each perfusion map. All perfusion CT maps showed the perfusion defect lesions in all patients. There were remarkable TTP and MTT delay in perfusion defect lesions. The lesions on CBF map was the most closely correlated with the lesions on DWMRI. The size of perfusion defect lesions on TTP and MTT map was larger than that of lesions on DWMRI, suggesting that MTT map can evaluate the ischemic penumbra. Perfusion CT maps make it possible to evaluate not only ischemic core and ischemic penumbra, but also hemodynamic status in the perfusion defect area. These results demonstrate that perfusion CT can be useful to the diagnosis and treatment in the patients with acute cerebral ischemic infarction.

Use of Quantitative CT to Predict Postoperative Lung Function (Comparison of Quantitative CT and Perfusion Lung Scan) (폐절제술후의 폐기능 예측에 대한 나선식 정량적 CT의 유용성 (나선식 정량적 CT와 폐관류스캔과의 비교))

  • 이조한
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.798-805
    • /
    • 2000
  • Background : the prediction on changes in the lung function after lung surgery would be an important indicator in terms of the operability and postoperative complications. In order to predict the postoperative FEV1 - the commonly used method for measuring changes in lung function- a comparison between the quantitative CT and the perfusion lung scan was made and proved its usefulness. Material and Method : The subjects included 22 patients who received perfusion lung scan and quantitative CT preoperatively and with whom the follow-up of PFT were possibles out of the pool of patients who underwent right lobectomy or right pneumonectomy between June of 1997 and December of 1999. The FEV1 and FVC were calibrated by performing the PFT on each patient and then the predicted FEV1 and FVC were calculated after performing perfusion lung scan and quantitative CT postoperatively. The FEV1 and FVC were calibrated by performing the PFT after 1 week and after 3 momths following the surgery. Results : There was a significant mutual scan and the actual postoperative FEV1 and FVC at 1 week and 3 months. The predicted FEV1 and FVC(pneumonectomy group : r=0.962 and r=0.938 lobectomy group ; r=0.921 and r=913) using quantitative CT at 1 week postoperatively showed a higher mutual relationship than that predicted by perfusion lung scan(pneumonectomy group : r=0.927 and r=0.890 lobectomy group : r=0.910 and r=0.905) The result was likewise at 3 months postoperatively(CT -pneumonectomy group : r=0.799 and r=0.882 lobectomy group : r=0.934 and r=0.932) Conclusion ; In comparison to perfusion lung scan quantitative CT is more accurate in predicting lung function postoperatively and is cost-effective as well. Therefore it can be concluded that the quantitative CT is an effective method of replacing the perfusion lung scan in predicting lung function post-operatively. However it is noted that further comparative analysis using more data and follow-up studies of the patients is required.

  • PDF

Clinical Application of Acute Ischemic Stroke in Perfusion Computed Tomography (초급성 허혈성 뇌졸중에서 관류 전산화단층촬영의 임상적 적용에 대한 연구)

  • Lee, Jong-Seok;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.149-160
    • /
    • 2007
  • Recent advent of 64-multidetctor (MD) CT enables more coverage of Z-axis in the perfusion imaging. The purpose of this study was to evaluate the clinical usefulness of perfusion CT by using 64-MD CT in detecting the lesion in patients with acute stroke. The perfusion CT was performed by using 64-MD CT in 62 consecutive patients who were initially suspected to have subacute ischemic stroke symptoms during the period of recent 9 months. These patients had subacute stroke (n=62). CT scanning was conducted with Jog Mode which provided 16 imaging slices with 5 mm of slice thickness, and 8 cm of coverage in Z-axis. Scan interval was 1 seconds for each imaging slice and total 15 scans were repeated. After CT scanning, perfusion maps (CBV, CBF, MTT and TTP) were created at Extended Brilliance Workstation. The CBV and CBF maps showed that lesions were smaller images. While on the MTT and TTP map lesions were seen to be larger fifty-one were large than they appeared on these images. Two slices of perfusion maps obtained at the level of the basal ganglia were chosen to simulate conventional older perfusion CT with 8 cm of coverage in Z-axis. TTP and MTT maps may be clinically useful for evaluation of the penumbral zone in cases of aubacute cerebral ischemic stroke. The perfusion CT is useful in the assessment of acute stroke as an initial imaging modality.

  • PDF

Perfusion Computed Tomography in Predicting Treatment Response of Advanced Esophageal Squamous Cell Carcinomas

  • Li, Ming-Huan;Shang, Dong-Ping;Chen, Chen;Xu, Liang;Huang, Yong;Kong, Li;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.797-802
    • /
    • 2015
  • Background: The purpose of this study was to prospectively evaluate the predictive value of perfusion computed tomography (CT) for response of local advanced esophageal carcinoma to radiotherapy and chemotherapy. Materials and Methods: Before any treatment, forty-three local advanced esophageal squamous cell carcinomas were prospectively evaluated by perfusion scan with 16-row CT from June 2009 to January 2012. Perfusion parameters, including perfusion (BF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Seventeen cases received definitive radiotherapy and 26 received concurrent chemo-radiotherapy. The response was evaluated by CT scan and esophagography. Differences in perfusion parameters between responders and non-responders were analyzed, and ROCs were used to assess predictive value of the baseline parameters for treatment response. Results: There were 25 responders (R) and 18 non-responders (NR). Responders showed significantly higher BF (R:34.1 ml/100g/min vs NR: 25.0 ml/100g/min, p=0.001), BV (23.2 ml/100g vs 18.3 ml/100g, p=0.009) and PED (32.5 HU vs 28.32HU, P=0.003) than non-responders. But the baseline TTP (R: 38.2s vs NR: 44.10s, p=0.172) had no difference in the two groups. For baseline BF, a threshold of 36.1 ml/100g/min achieved a sensitivity of 56%, and a specificity of 94.4% for detection of clinical responders from non-responders. Conclusions: The results suggest that the perfusion CT can provide some helpful information for identifying tumors that may respond to radio-chemotherapy.

CT Assessment of Myocardial Perfusion and Fractional Flow Reserve in Coronary Artery Disease: A Review of Current Clinical Evidence and Recent Developments

  • Chun-Ho Yun;Chung-Lieh Hung;Ming-Shien Wen;Yung-Liang Wan;Aaron So
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1749-1763
    • /
    • 2021
  • Coronary computed tomography angiography (CCTA) is routinely used for anatomical assessment of coronary artery disease (CAD). However, invasive measurement of fractional flow reserve (FFR) is the current gold standard for the diagnosis of hemodynamically significant CAD. CT-derived FFRCT and CT perfusion are two emerging techniques that can provide a functional assessment of CAD for risk stratification and clinical decision making. Several clinical studies have shown that the diagnostic performance of concomitant CCTA and functional CT assessment for detecting hemodynamically significant CAD is at least non-inferior to that of other routinely used imaging modalities. This article aims to review the current clinical evidence and recent developments in functional CT techniques.

Clinical Feasibility of CT Brain Perfusion in a Dog with Sellar Region Tumor

  • Minji Kim;Gunha Hwang;Jeongmin Ryu;Jiwon Yoon;Moon Yeong Choi;Joong-Hyun Song;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.41 no.3
    • /
    • pp.178-182
    • /
    • 2024
  • A 10-year-old spayed female Poodle was referred for blindness. On ophthalmic examination, loss of bilateral ocular pupil light reflex, visual loss, and right retinal detachment were confirmed at a local hospital. Magnetic resonance imaging (MRI) of the brain was performed to identify the optic nerve, optic chiasm, and brain disease. A sessile mass centered on the region of the optic chiasm was identified. The mass had iso- to hypointense on fluid-attenuated inversion recovery and T2-weighted images and mildly hypointense on T1-weighted images compared to the gray matter, with strong contrast enhancement. Peripheral edema was also identified. Computed tomography (CT) brain perfusion was performed to obtain additional hemodynamic information about the patient using a multislice CT. CT perfusion showed that the cerebral blood volume in the left temporal lobe region (13.4 ± 1.6 mL/100 g) was decreased relative to the contralateral region (19.9 ± 0.3 mL/100 g). The patient showed decreased appetite and consciousness one week after the CT scan with clinical symptoms worsened. The patient had seizure, tetraparesis, and loss of consciousness. It was euthanized one month later at the request of the owner. This report suggests that CT brain perfusion can provide additional hemodynamic information such as insufficient brain perfusion in sellar region tumor which can help assess potential complications and prognosis and plan treatment.

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Availability of Positron Emission Tomography-Computed Tomography for the Diagnosis of the Soft Tissue Tumor through Ultrasound-Guided Biopsy (초음파 유도하 침 생검을 이용한 연부조직 종양의 진단에 있어 양전자방출 컴퓨터 단층촬영술의 유용성)

  • Jun, Se Bin;Kim, Jeung Il;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.398-403
    • /
    • 2021
  • Purpose: A biopsy is needed to diagnose soft tissue tumors. However, it is extremely difficult to pinpoint the site of a tumor due to the heterogeneity of sarcomas. Thus, even when an open biopsy is conducted, it is difficult to diagnose a soft tissue tumor. In such cases, an ultrasound (US)-guided biopsy is used to improve the diagnostic accuracy. This study evaluated the accuracy of US-guided biopsy for a diagnosis of soft tissue tumors found initially in a magnetic resonance (MR) perfusion and assessed the availability of positron emission tomography-computed tomography (PET-CT) for a diagnosis of soft tissue tumors. Materials and Methods: From January 2014 to December 2018, the US-guided biopsy was performed on 152 patients with a suspected soft tissue tumor found in an MR perfusion and 86 cases were definitively diagnosed with a soft tissue tumor. The accuracy of the US-guided biopsy was assessed retrospectively. Among the 86 cases, only MR perfusion was used before the biopsy in 50 cases, while both MR perfusion and PET-CT was conducted on 36 cases. The accuracy was analyzed to determine if the PET-CT could improve the precision of a biopsy. Results: From 86 cases, 34 out of 50 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 32 out of 36 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis and the US-guided biopsy. These results show significant differences in the accuracy of US-guided biopsy. In the case of soft tissue sarcomas, 6 out of 12 cases, in which only MR perfusion had been conducted, matched the result of the definitive diagnosis and the US-guided biopsy. 17 out of 18 cases, in which both PET-CT and MR perfusion were conducted, matched the definitive diagnosis. Moreover US-guided biopsy also showed significant differences in the accuracy of US-guided biopsy. Conclusion: In diagnosing soft tissue tumors, a US-guided biopsy is a well-known tool for its high accuracy. However, the heterogeneity of sarcoma makes it difficult to locate the exact site for a biopsy using only MR perfusion. Thus, the use of PET-CT will meaningfully improve the accuracy of a diagnosis by precisely targeting the site for the US-guided biopsy.