• Title/Summary/Keyword: Performance variation

Search Result 4,208, Processing Time 0.035 seconds

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions (2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.

Computational Fluid Dynamics Study on Performance Variation of PEMFC with Serpentine Flow Fields According to Humidity Condition (가습조건이 사형유로를 채택한 고분자 전해질 연료전지의 성능에 미치는 영향에 대한 전산유체역학 해석 연구)

  • Oh, Gyu-Hwan;Lee, Kyu-Jin;Nam, Jin-Hyun;Kim, Charn-Jung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.8
    • /
    • pp.604-612
    • /
    • 2009
  • Water management has been recognized as a crucial factor for achieving better performance and stability in polymer electrolyte membrane fuel cells (PEMFCs). Proper water management should provide favorable water conditions, including the local humidity, membrane water content, and liquid water saturation in PEMFCs, thereby leading to more uniform electrochemical reaction and current generation. In this study, computational fluid dynamics (CFD) simulation was conducted to investigate the effects of the cathode relative humidity (RH) on the performance of a 3 by $3\;cm^2$ PEMFC with serpentine flow fields. The CFD results showed that the best performance of the PEMFC was obtained for the cathode RH of 80%, but the performance variation was small for the cathode RH range of $60{\sim}100%$. However, the loss of the PEMFC performance was significant when the cathode RH was reduced below 40%. The reason for such performance variation was investigated through the detailed inspection of ohmic loss, activation and concentration overpotential, and water and current distributions.

Performance improvement of a vehicle suspension by sensitivity analysis (민간도해석에 의한 자동차 현가장치의 성능개선에 관한 연구)

  • Song, Chuck-Gee;Park, Ho;Oh, Jae-Eung;Yum, Sung-Ha
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1464-1473
    • /
    • 1990
  • Optimal design parameters are estimated from the sensitivity function and performance index variation. Suspension design modification for performance improvement and basic materials for practical applications are presented. The linear quarter model of a vehicle suspension is analyzed in order to represent the utilities of sensitivity analysis, and sensitivity function is determined in the frequency domain. The change of frequency response function is predicted, which depends on the design parameter variation and the property is verified by computer simulation. As an investigation results of sensitivity function for the vibrational amplitude of sprung mass to road profile input, it is shown that the most sensitive parameters are the suspension damping and the suspension stiffness. In order to identify the effects of these two parameters to the performance of suspension system, the performance index variation according to the changes of parameters is considered and then optimal design parameters are determined. It is verified that the system response is improved noticeably in the both of frequency and time domain after the design modification with the optimal parameters.

Impact of Channel Variations and Channel Estimation Errors on the Error Performance of Convolutional Coded STBC Systems (길쌈 부호화 시공간 블록 부호 시스템의 오류 성능에 대한 채널 변화 및 채널 추정 오류의 영향)

  • Yun, Eunsik;Kim, Sun-Hyung;Park, Sangjoon;Kang, Byeong-Gwon
    • Journal of Digital Convergence
    • /
    • v.16 no.5
    • /
    • pp.231-237
    • /
    • 2018
  • This paper investigates the impact of the channel variations and channel estimation errors on the error performance of convolutional coded STBC systems. We consider the orthogonal Almouti STBC and the quasi-orthogonal Jafarkhani STBC, and the error performance of the convolutional coded STBC system is investigated according to the channel variation and channel estimation error via numerical simulations. Simulation results show that, if the channel variation speed is slow, time diversity effects improve the error performance compared to the static-channel cases. However, if the channel variation speed is fast, unlike ZF or MMSE detection, the conventional STBC detection has the significant performance degradation especially with the quasi-orthogonal Jafarkhani STBC. Further, the error performance of the system is significantly degraded as the channel estimation errors become stronger, regardless of the detection scheme and channel variation speed.

Conformance-Based Dynamic Performance Optimization of an Actuator (순응도 기반의 구동기 동적 성능 최적화)

  • Son, Young-Kap
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1327-1334
    • /
    • 2012
  • This study shows the conformance-based design results of a fourth-order dynamic actuator showing a performance variation caused by variation in the components as well as aero-induced disturbances. The actuator comprises a BLDC motor, spur gear and worm gear assembly, and canard. The actuator performance was evaluated by using time-variant angle information of the canard. Based on the response surface models, critical system variables were screened using F-tests, and then, the performance was approximated as a function of the variables because it is difficult to determine the performance of a high-order dynamic system as a function of system variables through analytical approaches. In this study, the conformance of uncertain performance to the specification was defined as a probability measure. The design variables obtained by optimizing the measure can provide actuator performance conforming to the specifications considered, even though there is a variation in both the components and the aero-induced disturbances.

Robust tracking controller design for a load variation (부하변화에 견실한 추적 제어기 설계)

  • 김광태;정구락;김재환;박원철;박래석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.629-632
    • /
    • 1991
  • Load Variation effects on the system driving performance. Therefore, this paper presents as a application example of Anti-windup method using general incremental form for a gun servo system of load variation involved. Also, this method can be easily implemented compared to gain scheduling technique.

  • PDF

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

PWM Converter Control considering time varying source voltage (Time Varying 전원 전압을 고려한 PWM 컨버터 제어)

  • 주인원;임선경;남광희
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.692-695
    • /
    • 1999
  • A new control scheme is proposed suitable for the three phase PWM converter having abrupt load variation such as a crane. In the converter used in a crane, the peak value of source voltage varies instantaneously due to the abrupt load variations. Such a voltage variation degrades the performance of DC-link control of PWM converter. To overcome this problem, load variations should be detected and compensated properly. We propose a new method for detecting and compensating the load variations without the additional hardware. With the proposed scheme, load variations are detected by estimating the current of DC-link capacitor. The estimated current information is feedbacked to a current controller to improve the performance. Additionally, the variation of source voltage is compensated using feedforward controller. The performance of the proposed scheme has been verified through simulations.

  • PDF

The effect of bolt tightening methods and sequence on the performance of gasketed bolted flange joint assembly

  • Abid, Muhammad;Khan, Yasir Mehmood
    • Structural Engineering and Mechanics
    • /
    • v.46 no.6
    • /
    • pp.843-852
    • /
    • 2013
  • This paper presents results of the effect of different bolt tightening sequences and methods on the performance of gasketed bolted flange joint using nonlinear finite element analysis. Bolt preload scatter due to elastic interactions, flange stress variation and bolt bending due to flange rotation and gasket contact stress variation is difficult to eliminate in torque control method i.e. tightening one bolt at a time. Although stretch control method (tightening more than one bolt at time) eradicates the bolt preload scatter, flange stress variation is relatively high. Flange joint's performance is compared to establish relative merits and demerits of both the methods and different bolt tightening sequences.

Characteristics Improvement of Hydraulic Servosystem by Using Generalized Minimum Variance Adaptive Control (일반화최소분산 적응제어를 이용한 유압 서보계의 특성개선에 관한 연구)

  • 박용호;김기홍;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.388-394
    • /
    • 2003
  • Hydraulic system is difficult to obtain a suitable performance due to the nonlinearity load pressure change and system parameter variation. The requirement of control a1gorithm has been complex in order to satisfy the performance. The adaptive control is a control method which is suggested to achieve the control object under the plant characteristics change. In spite of the case that plant characteristics and the degree of variation are difficult to grasp. the adaptive control could keep the characteristics of closed-loop system generally. In this study. a method of combined generalized minimum variance adaptive control (GMVAC) and output error feedback is proposed, in order to solve the problem of non-minimum phase of plant and the vibration and overshoot in initial response. The control performance according to the variation of characteristics of plant is evaluated by changing the supply pressure. The experimental results show the effectiveness of the proposed scheme.