• 제목/요약/키워드: Performance tests

검색결과 6,743건 처리시간 0.033초

Influence of design modification of control rod assembly for Prototype Generation IV Sodium-cooled Fast Reactor on drop performance

  • Son, Jin Gwan;Lee, Jae Han;Kim, Hoe Woong;Kim, Sung Kyun;Kim, Jong Bum
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.922-929
    • /
    • 2019
  • This paper presents the drop performance test of the control rod assembly which is one of the main components strongly related to the safety of the prototype generation IV sodium-cooled fast reactor. To investigate the drop performance, a real-sized control rod assembly that was recently modified based on the drop analysis results was newly fabricated, and several free drop tests under different flow rate conditions were carried out. Then the results were compared with those obtained from the previous tests conducted on the conceptually designed control rod assembly to demonstrate the improvement in performance. Moreover, the drop performance tests under several types and magnitudes of seismic loadings were also conducted to investigate the effect of the seismic loading on the drop performance of the modified control rod assembly. The results showed that the effects of the type and magnitude of the seismic loading on the drop performance of the modified control rod assembly were not significant. Also, the drop time requirement was successfully satisfied, even under the seismic loading conditions.

수정된 광폭침목(MF-140 PSC 침목)의 성능평가 (Performance Evaluation of Modified Wide Sleepers(MF-140 PSC Sleepers))

  • 배영훈;이일화;정찬민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1667-1673
    • /
    • 2011
  • For performance evaluation of modified wide sleepers(MF-140 PSC sleepers), design moment for urban transit was calculated and then performance evaluation criteria were set up according to EN 13230-2. Next, static bend tests, dynamic tests at rail seat section of sleeper were carried out and static bend tests at center section of sleeper were fulfilled. The test results for modified wide sleepers were in excess of performance evaluation criteria and structural safety of sleepers was able to guaranteed from the results. As modifying depth of wide sleepers, construction convenience in underground will be expected to be improved and construction costs will be expected to be decreased.

  • PDF

공명기 배열을 이용한 중속 디젤엔진 배기 소음기의 저주파수 대역 성능 개선 연구 (A Study on the Performance Improvement of Medium Speed Diesel Engine Exhaust Silencer in the Low-frequency Range Using Array Resonators)

  • 김영현;주원호;배종국
    • 한국소음진동공학회논문집
    • /
    • 제19권7호
    • /
    • pp.693-698
    • /
    • 2009
  • Various acoustic tests were carried out to investigate the acoustic performance of diesel engine exhaust silencers. In order to consider flow effects, the test facility was set up composed of fan, duct and silencer. Using the test facility, insertion loss tests were carried out to improve the acoustic performance in the low-frequency ranges. Through a series of tests, it was found out that the array resonators having multi-perforated holes inside the exhaust silencer, might be very effective in the low frequency range. Consequently, the hybrid-type silencer which is the combination of reflective silencer with array resonators and conventional absorptive silencer, was proposed and its high performance in the low-frequency range was also verified.

공명기 배열을 이용한 디젤엔진 소음기의 저주파수 대역 성능 개선 연구 (A Study on the Improvement of Acoustic Performance of Diesel Engine Exhaust Silencer in the Low-Frequency Range using Array Resonators)

  • 이태경;김영현;주원호;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.30-35
    • /
    • 2007
  • Various acoustic tests were carried out to investigate the acoustic performance of diesel engine exhaust silencers. In order to consider flow effects, test equipment composed of fan, duct and silencer was set up. Using the test equipment, insertion loss tests were carried out to improve the performance in the low-frequency ranges. Through a series of tests, the fact that array resonators may be effective in the low-frequency noise has been verified. Consequently, the hybrid-type silencer which is the combination of reflective silencer with array resonators and conventional absorptive silencer were proposed and its high acoustic performance in the low-frequency range has also been verified.

  • PDF

PC 기반 가상계측시스템에 의한 유니버설 모터 성능 시험법 확립 (Establishment of Performance Tests Methods of Universal Motors Using PC-Based Virtval Instrumentation System)

  • 이성호;장석명;김영관;김덕진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권3호
    • /
    • pp.116-123
    • /
    • 2003
  • This paper deals with an experimental study for on-line monitoring the performance of a universal motor for vacuum cleaner. Performance tests are conducted on the PC-based virtual instrumentation system designed using the graphical programming language LabVIEW. The proposed monitoring system is capable of performing real time measurement functions, including data acquisition, display, and analyses in the time and frequency domains, as well as data archiving. The measured mechanical and iron loss, voltage, current, input power, power factor, torque, and efficiency characteristics are presented as function of speed.

SMART 연구로 주냉각재펌프의 검증시험 (Qualification Test of a Main Coolant Pump for SMART Pilot)

  • 박상진;윤의수;오형우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

선미 스케그 주위의 유동 분석에 의한 선미 형상 설계 (The Stern Hull Form Design using the Flow Analysis around Stern Skeg)

  • 박동우
    • 대한조선학회논문집
    • /
    • 제45권4호
    • /
    • pp.361-369
    • /
    • 2008
  • The optimized distance between skegs and angle of the skeg for a standard twin-skeg type LNG carrier were presented using the CFD and model tests. The evaluation method of self-propulsion performance was derived based on the results of CFD and confirmed the validity through model tests. The analyses to assess self-propulsion performance using CFD were shown by flow line patterns on the skeg surface, nominal wake distribution in the propeller plane and the evaluation for flow balance around stern skegs. The optimized ship that was applied to the optimized two design parameters in stern skeg arrangement for target ship was derived in this work. Finally speed performance of mother ship which is existing ship and optimized ship were compared through CFD and model tests. And the usefulness about the evaluation method of self-propulsion performance was reconfirmed.

로켓엔진용 연료펌프의 성능 시험

  • 김대진;홍순삼;최창호;김진한
    • 항공우주기술
    • /
    • 제4권1호
    • /
    • pp.143-149
    • /
    • 2005
  • 로켓엔진용 연료펌프의 수력 성능과 흡입 성능을 관찰하기 위해 연료펌프에 대한 성능시험을 실시하였다. 성능 시험은 수력 성능 시험과 흡입 성능으로 나뉘며 시험의 편의를 위해 상온의 물을 매질로 택하였다. 수력 성능 시험 결과 양정, 효율, 볼류트 압력 분포 등은 상사 법칙을 잘 만족하는 것으로 드러났으나, 이차 유로의 압력 분포는 상사 법칙과 약간의 차이를 보였다. 그리고 플로팅 링 간극을 줄였을 때 펌프의 양정과 효율 모두 좋아지는 것을 확인할 수 있었고, 바이패스 배관의 오리피스 변화는 연료펌프의 효율 변화와 특별한 경향성을 보이지 않았다. 마지막으로 흡입 성능 시험 결과 펌프의 시험 회전수를 높였을 때 펌프의 흡입 성능이 증가하는 것을 관찰할 수 있었다.

  • PDF

개발 화약의 내폭풍압 측정 (Internal Blast Tests of Developed Explosives)

  • 김성호;김정국;이준웅
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.122-128
    • /
    • 2004
  • Internal blast performance test on developed explosives was carried out. Internal blast means a blast wave in closed chambers like tunnels, bunkers, operation center and chamber of ships. We used Anpa tunnel for our test facility. We performed two series of tests to measure internal blast of developed explosives. Three different kinds of cast PBXs, DXD-09, DXD-10, DXD-18, and conventional explosive, Tritonal, were used in our test. The explosives were cast as a charge of 108mm diameter in a plastic tube of a 3mm thickness. The length of charges 4ere adjusted as a weight 3kg. A melt-cast explosive, tritonal, was used as a reference. Pentolite booster was used. The cylindrical boosters have a 95mm diameter and 47.5mm height. The results showed that there may be some differences between the performances in the air blast tests and those in the internal blast tests. The results showed that DXD-10, the best performance in air blast tests, showed the poorest performance in internal blast among the explosives tested. On the other hand, DXD-18 showed exactly the opposite trend. This is probably due to the highest contents of aluminum and inert binder in DXD-18. DXD-18 has $38\;wt\;\%$ of aluminum and $17\;wt\;\%$ of inert binders.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.