• Title/Summary/Keyword: Performance standards

Search Result 2,356, Processing Time 0.031 seconds

An Analysis of Achievement Standards Statements in the Elementary Mathematics Curriculum of Korea (초등학교 수학과 교육과정 성취기준 진술 방식 분석)

  • Cho, Inyoung;Kang, Wan
    • Journal of Elementary Mathematics Education in Korea
    • /
    • v.22 no.1
    • /
    • pp.69-92
    • /
    • 2018
  • In this study, we analyzed whether 2015 revised elementary school mathematics curriculum 's standards statements reflect the direction of 2015 revised curriculum. For the objectivity of analysis, 128 achievement standards statements were analyzed based on content - centered statements, activity - centered statements, and performance - centered statements by Seo Young - jin 's (2013). As a result of the analysis, it can be seen that the 2015 revision elementary mathematics curriculum achievement standards statements do not contain enough information to expand the mathematical competence of students. To complement this, the achievement standards statements should include more elements than 'content + function', and other criteria should be developed to clearly communicate the meaning of the achievement standards statements. And it is necessary to supplement the expression of 'function' in the achievement standards in order to improve the expression of the elementary school mathematics curriculum achievement standards statements.

  • PDF

A Study on Performance Test Standards for High-speed Rolling-stock System (고속철도 차량성능기준(안) 작성에 관한 연구)

  • Wang Jong-Bae;Park Chan-Woo;Kwak Sang-Log
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.569-574
    • /
    • 2005
  • In this study, test standards were developed for performance verification of the high speed(350km/h) rolling-stock. The performance test system consist of three type tests; the component test for core item, the completed car test for combined function & operation and the trial driving test for compatibility & interrelationship with infrastructure.

  • PDF

Can irregular bridges designed as per the Indian standards achieve seismic regularity?

  • Thomas, Abey E.;Somasundaran, T.P.;Sajith, A.S.
    • Advances in Computational Design
    • /
    • v.2 no.1
    • /
    • pp.15-28
    • /
    • 2017
  • One of the major developments in seismic design over the past few decades is the increased emphasis for limit states design now generally termed as Performance Based Engineering. Performance Based Seismic Design (PBSD) uses Displacement Based Design (DBD) methodology wherein structures are designed for a target level of displacement rather than Force Based Design (FBD) methodology where force or strength aspect is being used. Indian codes still follow FBD methodology compared to other modern codes like CalTrans, which follow DBD methodology. Hence in the present study, a detailed review of the two most common design methodologies i.e., FBD and DBD is presented. A critical evaluation of both these methodologies by comparing the seismic performance of bridge models designed using them highlight the importance of adopting DBD techniques in Indian Standards also. The inherent discrepancy associated with FBD in achieving 'seismic regularity' is highlighted by assessing the seismic performance of bridges with varied relative height ratios. The study also encompasses a brief comparison of the seismic design and detailing provisions of IRC 112 (2011), IRC 21 (2000), AASHTO LRFD (2012) and CalTrans (2013) to evaluate the discrepancies on the same in the Indian Standards. Based on the seismic performance evaluation and literature review a need for increasing the minimum longitudinal reinforcement percentage stipulated by IRC 112 (2011) for bridge columns is found necessary.

A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System (거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구)

  • Huh, Ye-Rim;Kim, Yoon-Seong;Kim, Hye-won;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF

A Study on the Analysis and Improvement of Medical Device Standards in Korea (국내 의료기기 표준 분석 및 개선에 관한 연구)

  • Yong Wan Kang;Kyung Ah Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.204-210
    • /
    • 2023
  • This study focuses on analyzing medical device standards and regulatory requirements in the medical device industry, based on the Medical Device Act in Korea. The objective of this analysis is to determine whether the domestic standards for medical devices in Korea align with international and regional standards. Furthermore, it aims to identify the current application of domestic standards in ensuring the safety and essential performance of medical devices. The analysis revealed that out of a total of 281 domestic standards, 127 standards reference international standards. In terms of the application of domestic standards to specific items, there were 473 types of instruments/machines, 30 types of medical supplies, and 45 types of dental materials. However, the level of compliance with international standards among the domestic medical device standards was only 21%. Upon detailed analysis, general and collateral standards accounted for 24%, while particular standards accounted for 19%. This indicates a significant deviation from the latest international standards. On the other hand, the level of compliance with international standards was analyzed to be 60% for particular standards and 72% for general and collateral standards in Korean industrial standards (KS). Considering these results, the disparities between domestic standards and international standards underscore the need for discussions on domestic medical device regulation and standardization. In conclusion, this study emphasizes the significance of maintaining up-to-date medical device standards and ensuring their alignment with international standards to ensure the safety and quality of medical devices. The findings highlight the necessity for further efforts to strengthen the domestic standardization system in order to promote the development of safe and high-quality medical devices.

Developing Achievement Standards, Assessment Standards, and Assessment Tools for "Intelligent Life" Course of Elementary School (초등학교 "슬기로운 생활" 교과를 위한 성취기준, 평가기준 및 평가도구 개발)

  • 배진호;안정민;김재영
    • Journal of Korean Elementary Science Education
    • /
    • v.23 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • To get an appropriate and meaningful performance assessment outcomes and to provide the base of essential elementary educational evaluations, we had tried to establish achievement standards, assessment standards and had developed appropriate assessment tools in 「Intelligent Life」 course of the elementary school in this study. The following things were taken into account to establish achievement standards, assessment standards and to develop assessment tools. First, managing deeply not only cognitive domain but also the basic inquiry skills and affective domain, all-round educational properties of integrated courses were likely to come out. Second, evaluating instructional processes as well as instructional results, we had developed assessment standards in elementary 2nd grade's 「Intelligent Life」 course. Third, developing assessment standards on the basis of the 7th Curriculum, we had examined both text book and teacher's guide to promote effectiveness of field application. The type of an assessment tools had been developed variously, considering the characteristics of the elementary lower grades and properties of elementary 2nd grade's 「Intelligent Life」 course. We had developed assessment tools to observe and evaluate practical achievement levels, placing great importance on the types of an assessment tools including observing, narrative of inquiry, report, etc. As a result of investigation of elementary teachers' understandings of the developed achievement standards, assessment standards, and an assessment tools, were revealed in the affirmative on the whole.

  • PDF

An Analysis of Performance Testing for Metallic Connection Components of Lightning Protection System (피뢰시스템 구성부품 중 금속접속재의 성능시험 및 결과분석)

  • Lee, Ju-Cheol;Lee, An-Ki;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.69-74
    • /
    • 2014
  • Recently, IEC published new standards about the requirements and tests for lightning protection system(LPS) components. If components are used for LPS, they should comply with the IEC standards. This paper, we collected six specimens for the metallic connection components using in domestic, and it tested for withstand lightning current which according to the IEC 62561-1. As a result, only one specimen meet this performance requirement. The specimen is the metallic connection component with four bolts fixed. Therefor, when designing of LPS in domestic, the metallic connection components shall be taken into account for the selection of the withstand lightning current. In addition, we need to develop for LPS components product and the national standards.

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

A Study on Standards for Performance Evaluation of Biometric Recognition Systems (국내 생체 인식 시스템 성능 평가를 위한 표준안 연구)

  • 문지현;김학일
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.2
    • /
    • pp.101-110
    • /
    • 2002
  • The purpose of this research is to establish Korean standards of best practice and common criteria for testing and evaluating the performance of biometric recognition systems. First of all, research activities in leading countries such as USA, Great Britain and Germany have been studied and analyzed. Then, the standards of best practice and common criteria are proposed in the aspects of sensors, algorithms, and application systems. The results of this work will be utilized fur test and evaluation of commercial biometric products by KISA and provided to private industries for their own evaluation of products.

The Study to Improve the Insulation Standards for Mechanical Pipes based on Energy Performance (에너지 성능 기반의 기계설비배관 단열기준 개선을 위한 연구)

  • Yun, Hiwon;Ryu, Hyung Kyou
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2021
  • The need for zero-energy building is increasing as a means of actively responding to climate change. Since pipe insulation is a factor that minimizes heat loss of cooling and heating facilities, it is necessary to check pipe insulation standards and prepare improvement plans of preparation for certification of zero energy buildings. In this study, domestic pipe insulation standards were checked to prepare new insulation standards based on energy performance. Through the development of a pipe insulation calculation program, the heat loss according to the insulation thickness of the piping for mechanical facilities was compared and reviewed. As a result, applying the insulation thickness of the KCS standard for the same conditions increased the heat loss by an average of 10% compared to the ASHRAE standard. For this reason, it is necessary to revise the pipe insulation thickness standard in consideration of heat loss due to thermal conductivity and pipe insulation thickness. Using the program in this paper, it is possible to design pipe insulation based on energy performance and help to determine the standard for pipe insulation thickness.