• Title/Summary/Keyword: Performance stage

Search Result 4,595, Processing Time 0.049 seconds

Analysis of application of motion graphics in the performing arts-Focuses on "Beyonce performs Run The World" (공면몌술메시 모션그래필의응용사계분석 -작품 "Beyonce performs Run The World")

  • Wang, Jia;Kim, Hae-Yoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.327-328
    • /
    • 2014
  • Modern life is surrounded by all kinds of information and screen, motion graphics in these media everywhere, you can use it to a special performance of the method, the use of the stage, so that the effect is more vivid stage performance. Stage design industry began to diversify the use of Motion graphic, have long been out of the framework of the traditional background, turn into dynamic video space. In this paper analysis of research papers by the dynamic changes in the graphics arena background, style, affect the application of dynamic images. Summed up in the stage of development that can adapt to the requirements of the times, better performance stage effects and express emotion of the stage performances.

  • PDF

A study on Media Characteristics of Stage Space in Middle Age and Renaissance Theater (중세(中世)와 르네상스 극장(劇場) 무대공간(舞臺空間)의 미디어적 특성에 관한 연구)

  • Kim, Sung-Kee;Park, Eun-Kon
    • Journal of architectural history
    • /
    • v.15 no.1 s.45
    • /
    • pp.61-76
    • /
    • 2006
  • The stage is ceremonial and legendary space unlike the ordinary world. Performance is not simply scrip-staged, but spatial art based on tempo that transmits extreme condition. The stage art is a visual art combined with stage settings, lighting, customs and the like. I exemplify the stage of Middle Age and Renaissance in the history of the art of public performance and so I review that what meditative functions each stage perform and that as what pattern of media it can be conceptualized. In this thesis, I divide the places of public performance Into the spaces of proscenium and polygon and also set up the concepts of hot and cool that McLuhan presents for each space. So, the degree of participation could be different according to the distinction of quantity of information, which is communication following the patterns of spaces. The basis of public performance might be the communication between co-actors and audiences. Since the sense of the art of public performance is the art in the process of establishing the meaning based on the communication with co-actors, it is not a confirmed and fixed one, but rather a reflexive one that can be created and changed continuously. Therefore, audiences should be regarded as the subjects, who are making the art of public performance with co-actors.

  • PDF

Simulation of a two-stage absorption heat pump cycle using treated sewage (하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션)

  • 이용화;신현준;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans (고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구)

  • Cho, Jinsoo;Han, Cheolhui;Cho, Leesang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

Influence of Low Stage Refrigerant Charge Amount on the Performance of Cascade Heat Pump (캐스케이드 열펌프의 저단 사이클 충전량 변화에 따른 성능 특성)

  • Park, Seung Byung;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • In this study, the optimization and performance characteristics of a cascade heat pump system was analyzed with the variation of low stage refrigerant charge amount. The cascade heat pump was designed and constructed with R134a and R410A as the refrigerant for high stage and low stage cycle, respectively. Experiments were conducted by varying the low stage charge amount and the performance characteristics of the cascade heat pump were studied. The refrigerant charge amount of the low stage cycle was varied between the ranges of -15% and +10% of the optimum charge amount. The performance variation experienced in the cascade heat pump due to the variation of refrigerant charge amount shows greater effect in the undercharge regions than the overcharge regions. COP reduction in the undercharge region is larger than the decrease in the overcharge region. Some cycle variation such as power consumption and cycle pressure according to low stage refrigerant charge amount showed different trends comparing with those according to high stage refrrgerant charge amount. Therefore, the optimum charge amount of the cascade heat pump should be determined based on the experimental data obtained by the variation of high and low stage refrigerant charge amount.

Development of a 3-axis fine positioning stage : Part 2. Experiments and performance evaluation (초정밀 3축 이송 스테이지의 개발 :2. 동특성 실험 및 성능 평가)

  • Kang, Joong-Ok;Kim, Man-Dal;Baek, Seok;Han, Chang-Soo;Hong, Sung-Wook
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1207-1210
    • /
    • 2003
  • This paper deals with experiments for dynamic characteristics and performance evaluation of the 3-axis fine positioning stage developed in [1]. The features of the developed fine positioning stage are the long stroke due to the magnetically preloaded PZT actuators, the minimum motion crosstalk due to the use of a ball contact mechanism and the compact design. The dynamic characteristics of the actuator and the stage are tested with the preload changed in order to validate the actuator and the stage design. Performance evaluation is also made for the PZT actuators as well as the stage positioning accuracy. Experimental results show that the developed stage is accurate enough to be used for nanometer positioning.

  • PDF

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

A Study on Characteristics of Stage and Auditorium Space of Modern Performing Arts Centers in America (현대미국공연장의 무대와 객석 공간 특성에 관한 연구)

  • Kim, Sung-Kee
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.40-48
    • /
    • 2009
  • This study aimed to analyze the types and characteristics of space forms according to the composition of the stage and auditorium space along with the expression trends in the space of performing arts centers through the cases of modern performing arts centers in America. Today since the purposes of performance are multiple, a variety of stage types are applied to each performing arts center. They use various spaces and performances of multiple purposes by moving and transforming the stage and auditorium according to the kinds of performance as a variation of the arena stage. In today's performing arts centers, the sizes of the stage and auditorium can vary widely, and the performances of many different genres are put to multiple purposes. There appear complex performing arts centers that can plan performing spaces of diverse sizes and forms to fit the functions of a performance in a large building. Since they put on performances in a large space according to the characteristics of the kind of performance, the intentions and goals of the performance are well delivered to the audience.

Comparisons of Performance in CO2 Systems with Operating Conditions (운전조건 변화에 따른 이산화탄소 냉방시스템들의 성능 비교)

  • Bae, Kyung-Jin;Shin, Eun-Sung;Cho, Hong-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1484-1490
    • /
    • 2009
  • Since the cooling performance of a $CO_2$ cooling cycle is varied significantly with a variation of refrigerant charge amount and outdoor temperature, the reliability of $CO_2$ system is down. In this study, the performance characteristics of three kinds of $CO_2$ systems were measured and analyzed by varying refrigerant charge amount and outdoor temperature so as to study the characteristics of variation with cycle option. The applied system options are the single-stage compression(1C-1E) system, two-stage compression with 1-EEV(2C-1E) system, and two-stage compression with 2-EEV(2C-2E) system. The performances of two-stage compression with 2-EEV system were less sensitive than those of other systems and the system operated safely and steadily for wide charge amount. The performance of the two-stage compression with 1-EEV(2C-1E) system was the most sensitive to the charge amount, and that of the single-stage compression(1C-1E) system varied a lot with outdoor temperature.

  • PDF

Comparative Study of Prediction Performance and Variable Importance in SEM-ANN Two-stage Analysis (SEM-ANN 2단계 분석에서 예측성능과 변수중요도의 비교연구)

  • Sun-Dong Kwon;Yi Zhao;Hua-Long Fang
    • Journal of Information Technology Applications and Management
    • /
    • v.31 no.1
    • /
    • pp.11-25
    • /
    • 2024
  • The purpose of this study is to investigate the improvement of prediction performance and changes in variable importance in SEM-ANN two-stage analysis. 366 cosmetics repurchase-related survey data were analyzed and the results were presented. The results of this study are summarized as follows. First, in SEM-ANN two-stage analysis, SEM and ANN models were trained with train data and predicted with test data, respectively, and the R2 was showed. As a result, the prediction performance was doubled from SEM 0.3364 to ANN 0.6836. Looking at this degree of R2 improvement as the effect size f2 of Cohen (1988), it corresponds to a very large effect at 110%. Second, as a result of comparing changes in normalized variable importance through SEM-ANN two-stage analysis, variables with high importance in SEM were also found to have high importance in ANN, but variables with little or no importance in SEM became important in ANN. This study is meaningful in that it increased the validity of the comparison by using the same learning and evaluation method in the SEM-ANN two-stage analysis. This study is meaningful in that it compared the degree of improvement in prediction performance and the change in variable importance through SEM-ANN two-stage analysis.