• Title/Summary/Keyword: Performance stage

Search Result 4,617, Processing Time 0.031 seconds

A study on the part-load performance of 2-stage water source heat pump (2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구)

  • Lee, Young-Soo;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

Petri Net based Performance Evaluation of Manufacturing Cell (페트리 넷을 이용한 제조 셀의 성능평가)

  • Kim, Tai-Oun;Seo, Yoon-Ho;Sheen, Dong-Mok
    • IE interfaces
    • /
    • v.17 no.spc
    • /
    • pp.152-159
    • /
    • 2004
  • The Purpose of this paper is to propose performance evaluation schemes of flexible manufacturing cell using a generalized stochastic Petri net. In the competitive and global manufacturing environment, to evaluate the feasibility and manufacturability of a product in the product design stage is highly required. Through this process, all the possible problems which may occur in the manufacturing stage can be fixed in early stage. The scheme of generalized stochastic Petri net utilizing both immediate and exponential distributed transitions are applied to model a manufacturing cell with flexible machines, material handler, transporter and buffers. Performance analyses are performed based on behavioral, structural and quantitative properties. A flexible manufacturing cell is evaluated using a Petri net simulator.

Performance of Carbon Dioxide System for Freezing and Refrigeration (이산화탄소를 이용한 냉동·냉장 시스템의 성능연구)

  • Kim, Yoonsup;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.81-86
    • /
    • 2015
  • Performance of freezing and refrigeration systems in supermarket, which utilized $CO_2$ as a refrigerant, was investigated by using the Pack Calculation II. The configuration of simulated systems was basic parallel refrigeration system, cascade system, and two-stage system. The $CO_2$ cascade system showed higher COP than basic parallel R404A system by 13% for MT and 62% for LT, respectively. Among the $CO_2$ cascade systems, R717(MT)-$CO_2$(LT) showed the highest performance. Open-type intercooler method showed higher performance than liquid injection for the two-stage $CO_2$ systems.

Study on stage hologram production for performing arts (공연예술을 위한 무대 홀로그램 연출에 관한 연구)

  • Lee, Hochul;Kang, Hyosoon
    • Journal of Korea Game Society
    • /
    • v.18 no.3
    • /
    • pp.79-86
    • /
    • 2018
  • Hologram that usually used in modern art performance and movie, is now also used in different area such as architecture, car design, IT, medicine, design and different types of multi-media art performance. This study is to analyze how hologram works in stage production and affect in variety types of art performance and also how it affects in future art performance.

An Empirical Study of the Determinants of Service Level Management and its Performance (혁신 의사결정 과정을 이용한 서비스 수준관리의 실행단계별 요인과 성과에 대한 실증 연구)

  • Koo, Chul-Mo;Nam, Ki-Chan
    • The Journal of Information Systems
    • /
    • v.16 no.3
    • /
    • pp.69-90
    • /
    • 2007
  • Recently, Service Level Management(SLM) including SLA has been developing to manage the level of information systems service. Although previous SLA studies have provided the conceptual model and critical success factors, the studies have not tested the effectiveness of the SLA by way of the empirical study. In this study, we applied an innovation decision making theory to our model and tested an empirical study using of a firm survey data. We suggested a SLM model, which consists of SLA planning, application, management dimensions. We found that the SLM's management stage has an impact on performance, whereas SLM's planning and application has not. At each sub dimensional analysis, there are found that adequate SLA indicators in the application stage influences performance and change management and feedback & reporting in the management stage influence performance.

  • PDF

A Study on Performance Measurement Indicators of Nursing Department in a Hospital (병원 간호조직 성과관리지표 개발에 관한 연구)

  • Kang, Kyeong-Hwa;Han, Yong-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.15 no.1
    • /
    • pp.106-115
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate the contribution score of nursing organizational level for Performance Management Indicators (PMIs) in the nursing department in a hospital. Methods: The process consisted of three stages. Stage I: The strategies based on 4 perspectives of Balanced Scorecard (BSC) were identified by BSC committee in the hospital nursing department. Stage II : PMIs according to the strategies were developed. Stage III : The contribution score according to nursing organizational level (nursing department, nursing unit, nurse) for PMIs were surveyed by questionnaire. Data was analyzed using descriptive statics and ANOVA test. Results: Eight strategies were defined according to 4 perspectives of BSC. Eighteen PMIs were determined according to the strategies. The nurse considered the contribution of nursing department most highly on the 13 among 18 PMIs. Conclusion: This study provided basic data for further study to identify the subject of responsibility on the strategic management of performance.

  • PDF

System design of an air-cooled 3-stage reciprocating air compressor and performance testing (공랭식 3단 왕복동 공기압축기의 시스템 설계 및 성능시험)

  • Lee, An-Seong;Kim, Yeong-Cheol;Jeong, Yeong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1380-1391
    • /
    • 1997
  • A 150 m$^{3}$/hr, 30 kg/cm$^{2}$, air-cooled 3-stage reciprocating air compressor is designed to be used in starting large diesel engines. A basic design procedure is presented to meet the targeted pressure and flow rate, and especially the volumetric efficiency. Temperature and stress analyses of the cylinder are performed using FEM modelings. The dynamics of valve system is analyzed and stress at the valve seat due to valve impact is evaluated. To reduce friction loss and wear at the compressor engine system, tribological design practices are suggested. Fin-type coolers are designed to dissipate generated compression heat at each stage. Finally, a prototype is manufactured and performance test is carried out utilizing an air tank. Performance results are compared to the design targets, other foreign specifications, and some quality standards.

Performance Analysis of a Carbon Dioxide(R744) Two-Stage Compression and One-Stage Expansion Refrigeration Cycle ($CO_2$용 2단압축 1단팽창 냉동 사이클의 성능 분석)

  • Roh, G.S.;Son, C.H.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.70-75
    • /
    • 2009
  • In this paper, cycle performance analysis of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature in the carbon dioxide two-stage refrigeration cycle. The main results were summarized as follows : The cooling capacity of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, compressor efficiency and gas cooling pressure, but decreases with the increasing mass flowrate ratio and evaporating temperature. The compression work of two-stage compression and one-stage expansion refrigeration system increases with the increasing superheating degree, outlet temperature of gas cooler, gas cooling pressure and evaporating temperature, but decreases with the increasing compressor efficiency and mass flowrate ratio. The COP of two-stage compression and one-stage expansion refrigeration system increases with the increasing compressor efficiency, but decreases with the increasing superheating degree, gas cooling pressure, mass flowrate ratio and evaporating temperature. Therefore, superheating degree, compressor efficiency, gas cooling pressure, mass flowrate ratio, outlet temperature of gas cooler and evaporating temperature of R744($CO_2$) two-stage compression and one-stage expansion refrigeration system have an effect on the cooling capacity, compressor work and COP of this system.

  • PDF

A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD (CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구)

  • MO, Jang-Oh;NAM, Koo-Man;KIM, You-taek;LEE, Young-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF

Robust Minimum-Time Control with Coarse/Fine Dual-Stage Mechanism

  • Kwon, Sang-Joo;Cheong, Joo-No
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1834-1847
    • /
    • 2006
  • A robust minimum-time control (RMTC) strategy is addressed and it is extended to the dual-stage servo design. Rather than conventional switching type sub-optimal controls, it is a reference following control approach where the predetermined minimum-time trajectory (MTT) is tracked by the perturbation compensator based feedback controller. First, the minimum-time trajectory for a mass-damper system is derived. Then, the perturbation compensator to achieve robust tracking performance in spite of model uncertainty and external disturbance is suggested. The RMTC is also applied to the dual-stage positioner which consists of coarse actuator and fine one. To best utilize the actuation redundancy of the dual-stage mechanism, a null-motion controller to actively regulate the relative motion between the two stages is formulated. The performance of RMTC is validated through simulation and experiment.