• 제목/요약/키워드: Performance of heat pump

검색결과 837건 처리시간 0.031초

인젝션형 가변속 스크롤 압축기를 적용한 히트펌프의 난방성능 특성에 관한 연구 (Heating Performance Characteristics of a Heat Pump with a Variable Speed Injection Scroll Compressor)

  • 고석빈;허재혁;조일용;김용찬
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.377-384
    • /
    • 2012
  • Vapor injection technique has been applied to prevent performance degrdation of a heat pump at low ambient temperatures. In this study, the heating performance of a heat pump with a variable speed injection scroll compressor using R-410A was investigated by applying sub-cooler vapor injection(SCVI) and flash tank vapor injection(FTVI). The heating performance of the heat pump was measured by varying compressor frequency and outdoor temperature. The heating capacity of the FTVI system was 8~10% higher than that of the SCVI system at all operating conditions. On the other hand, the heating performance improvement with the increase in the compressor frequency was more prominent in the SCVI system than in the FTVI system.

2-사이클 열펌프 건조기에서 건조과정에 대한 실험적 연구 (Experimental Study on the Drying Process in the Two-Cycle Heat Pump Dryer)

  • 이공훈;김욱중;김종률;이상열
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.636-641
    • /
    • 2008
  • Heat pump drying has a great potential for energy saving due to its high energy efficiency in comparison to conventional air drying. The heat pump dryer is usually operated at the temperature less than $50^{\circ}C$ and the drying temperature is limited to the operating temperature of the heat pump system. In order to increase the drying temperature, the special box-type heat pump dryer has been developed. The dryer uses the two-cycle heat pump system which has the two heat pump cycles for high and low temperature heating. The high temperature cycle uses the refrigerant 124 to get the temperature greater than $80^{\circ}C$ and the low temperature cycle uses the refrigerant 134a. The drying experiment has been carried out to figure out the performance of the dryer with the selected drying material.

  • PDF

온수 급탕 및 난방을 위한 히트 펌프 태양열 시스템의 성능 분석 (Performance Analysis of Solar Thermal System with Heat Pump for Domestic Hot Water and Space Heating)

  • 손진국
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.49-62
    • /
    • 2018
  • This study aims to analyze the performance of solar thermal system with heat pump for domestic hot water and heat supply. There are four types of system. Systems are categorized based on the existence of a heat pump and the ways of controlling the working fluid circulating from the collector. Working fluid is controlled by either temperature level (categorized as system 1 and 2) or sequential flow (system 3 and 4). Heat balance of the system, the solar fraction, hot water and heating supply rates, and performance of heat pump are analyzed using TRNSYS and TESS component programs. Technical specifications of the main facilities are as follow; the area of the collector to $25m^2$, the volumes of the main tank and the buffer tank to $0.5m^3$ and $0.8m^3$, respectively. Heating capacity of the heat pump in the heating mode is set to 30,000 kJ / hr. Hot water supply set 65 liters per person each day, total heat transfer coefficient of the building to 1,500 kJ / kg.K. Indoor temperature is kept steadily around $22^{\circ}C$. The results are as follows; 6 months average solar fraction of system 1 turns out to be 39%, which is 6.7% higher than system 2 without the heat pump, indicating a 25% increase of solar fraction compared to that of system 2. In addition, the solar fraction of system 1 is 2% higher than that of system 3. Hot water and heating supply rate of system 1 are 93% and 35%, respectively. Considering the heat balance of the system, higher heat efficiency, and solar fraction, as whole, it can be concluded that system 1 is the most suitable system for hot water and heat supply.

$CO_2$ 히트펌프 열교환기의 성능 해석 모델 개발 (Development of Performance Analysis Model of $CO_2$ Heat Pump Heat Exchanger)

  • 김민석;장영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.651-656
    • /
    • 2006
  • A performance analysis model has been developed for fin-tube type heat exchanger for $CO_2$ heat pump. The model uses the tube-by-tube method Because air-side thermal resistance has a great portion among total thermal resistances, it is important to understand air-side heat transfer characteristics. The air-side heat transfer correlation has been proposed from experiments using water. The developed model was confirmed by experimental results and can be used for the performance analysis of heat exchanger.

  • PDF

주거용 건물에서의 히트펌프 시스템 연성능 평가에 관한 연구 (Analysis Study of Seasonal Performance Factor for Residential Building Integrated Heat Pump System)

  • 강은철;민경천;이광섭;이의준
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.3-10
    • /
    • 2016
  • 국내 히트펌프 유닛에 대한 성능 기준은 KS C 9306에서 제시하는 표준조건에서의 COP로 표현된다. 그러나 히트펌프 시스템이 실제 건물에 적용될 경우에는 표준조건에서 운전되는 것이 아니기 때문에 현장의 기후 조건, 건물의 특성에 따라 히트펌프 시스템의 성능은 다르게 나타난다. 본 논문에서는 주거건물을 대상으로 국내 주요 도시의 기후 조건에 따른 공기 대 공기 히트펌프 시스템의 연성능을 평가하여 기존의 BIN 데이터를 활용한 연성능 평가 결과와 정량적으로 비교 분석하였다. 연성능 평가도구로는 IPMVP 4.4.2에서 제시한 국제호환형 프로그램인 TRNSYS를 사용하였다. 공기 대 공기 히트펌프 유닛의 멀티 성능 데이터를 적용한 경우, 연성능 평가 기준인 APF는 BIN 데이터를 적용했을 때보다 전체적으로 높았으며, 부산이 2.36으로 가장 높았고, 대전이 2.29로 가장 낮았다.

공냉식 방사형 열교환기를 갖는 흡착식 히트펌프의 성능 (Performance of adsorption heat pump with radial shape adsorber heat exchanger for air cooling)

  • 백남춘;양윤섭;윤응상;이진국;주문창
    • 설비공학논문집
    • /
    • 제9권1호
    • /
    • pp.73-81
    • /
    • 1997
  • In this experimental study, the air cooling radial shape heat exchanger which influences on the COP and the cooling capacity by heat and mass transfer rate in the adsorbent bed was designed and applied to test its performance for adsorption heat pump(AHP). Zeolite-water was used for the adsorbent-adsorbat pair. As a result, the cooling COP and a cycle period of this adsorption heat pump are 0.28 and 2 hours, respectively, on the condition of none heat recovery from the adsorption reactor(absorber). The other results and recommendations are mainly related to improving the heat and mass transfer inside the absorber to reduce a cycle period.

  • PDF

열교환기 용량변화에 따른 하천수열원 열펌프의 성능 변화 (Performance Variations of River Water Source Heat Pump System According to Heat Exchanger Capacity Variations)

  • 박성룡;백영진;김희환;이영수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1530-1535
    • /
    • 2003
  • The utilization of unused energy is important because it can afford to offer a chance to increase energy efficiency of a heat pump system. One of the promising unused energy sources is river water. It can be used as a heat source in both heating and cooling effectively with its superior features as a secondary working fluids. In this study, the performance of a 5HP heat pump system using river water as a heat source is investigated by both experiment and simulation. According to system simulation results, performance improvement of condenser seems more effective than that of evaporator for better $COP_H$. The serial connection is also preferred among several methods to improve plate type heat exchanger performance. The experimental results show that the hot water of $50{\sim}60^{\circ}C$ can be acquired from water heat source of $5{\sim}9^{\circ}C$ with $COP_H$ of $2.7{\sim}3.5$.

  • PDF

복합열원 히트펌프 최적 제어를 위한 열원에 따른 히트펌프 성능 및 에너지 소요량 패턴 비교 (Comparison of Heat Pump Performance and Energy Consumption Patterns according to Heat Sources for Optimal Control of Multi-Source Heat Pumps)

  • 고유진;박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권4호
    • /
    • pp.31-38
    • /
    • 2020
  • The investment in the technology of using a combined heat source is insufficient, which utilizes the advantages of various heat sources to maximize the potential energy and at the same time increases the performance of the heat pump. In this study, as basic data for the development of a high-efficiency hybrid heat pump system that actively connects and uses various heat sources, simulations were conducted for the heat pumps in two cases where geothermal and hydrothermal heat were applied respectively. In May, COP increased by about 27.3% compared to geothermal heat. In February, the COP percentage decrease of hydrothermal heat compared to geothermal heat is -6.9%. In May, total energy consumption can be reduced by 21.1% when hydrothermal is applied compared to geothermal heat. In February, the total energy consumption increases by 3.4%.

Performance of a 2 Room Multi-Heat Pump with a Constant Speed Compressor

  • Kwan Young Chul;Kwon Jeong-Tae;Jeong Ji Hwan;Lee Sang Jae;Kim Dae Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.184-191
    • /
    • 2004
  • In order to improve the performance of a 2 room heat pump with a constant speed compressor, the optimum refrigeration circuit of the heat pump with different cooling and heating capacities is developed by applying capillary tubes. The refrigeration circuit is composed of four parts; a heating circuit, a cooling circuit, a by-pass circuit and a balance circuit. The performance of the 2 room heat pump are investigated from a rating experiment and a reliability experiment, using the calorimeter. Results of the rating experiment show that the capacity of heat pump is about $93\%$ of the design value. In particular, the capacity of the cooling single operation is about $13\%$ higher than the design value, and the capacity of the heating multi operation is about $5\%$ higher than the design value. From the reliability experi-ment, it is found that the lowest driving voltage of the compressor is about $75\%$ of the rating voltage. Also the compressor is reoperated normally under the flood back and the over load.

대형 Community 건물의 연료전지 구동 복합열원 하이브리드 히트펌프 시스템 성능에 관한 해석적 연구 (Study on the Performance of Fuel Cell Driven Compound Source Heat Pump System to a Large Community Building)

  • 정동화;변재기;최영돈;조성환
    • 신재생에너지
    • /
    • 제4권3호
    • /
    • pp.23-35
    • /
    • 2008
  • In the present study, performances of fuel cell driven compound source hybrid heat pump system applied to a large community building are simulated. Among several renewable energy sources, ground, river, sea, and waste water sources are chosen as available alternative energies. The performance and energy cost are varied with the hybrid heat pump sources. The system design and operation process appropriate for the surrounding circumstance guarantee the high benefit of the heat pump system applied to a large community building. Th system is driven by fuel cell system instead of the late-night electricity due to the advantages of the low energy cost and waste heat with high temperature.

  • PDF