• Title/Summary/Keyword: Performance of Product Safety

검색결과 272건 처리시간 0.021초

Performance Evaluation of Seismic Stopper using Structural Analysis and AC156 Test Method

  • Ryu, Hyun-su
    • 해양환경안전학회지
    • /
    • 제26권3호
    • /
    • pp.277-285
    • /
    • 2020
  • Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.

신제품개발 능력과 성과에서 최고경영자와 팀역할의 효과 (The Role Effect of Top Management and Team Operations on the Capabilities and Performance of New Product Development)

  • 강병서
    • 한국경영과학회지
    • /
    • 제17권1호
    • /
    • pp.1-1
    • /
    • 1992
  • This study examined the role effect provided by top management and team operations in applying the inner capabilities of R&D manufacturing and marketing to the performances of new product development. In examining the relationships of the factors in the study direct and indirect effects were determined in the structural model. Implications for new product development were made in the conclusive section.

조립식 가설기자재의 완성품에 대한 안전인증 타당성 연구 (A Feasibility Study of Safety Cetification for Finished Product of Febricated Temporary)

  • 이정석;최진우
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2013년 추계학술대회
    • /
    • pp.39-48
    • /
    • 2013
  • Recently, the using of prefabricated temporary equipments is increasing in the industrial field because it can reduce the installation and dismantling period. The various types of prefabricated temporary equipments are manufacturing with various materials in domestic and overseas countries. However, those equipments should win the safety certificate according to the "Governmental Notification about Safety Certification" which regulate the member-based safety certification. It tends to cause over performance of temporary equipments because it couldn't consider structural benefit of the prefabricated products. As the result of this study, it is concluded that the establishment of new safety certification standard for the prefabricated temporary equipments is resonable and the movable scaffold is appropriate for those prefabricated temporary equipment. The movable scaffolds are using as single structure and cannot be expands horizontally. Other types of temporary equipments are using as complex structure which can freely expand horizontally according to the main structure. From the results of the study, the standard of vertical compression performance of prefabricated movable scaffolds should be more than double the performance of single main frame. Other test items of safety certification standard should be fixed when the Notification is amended. The prefabricated temporary equipments which are adopted for the safety standard on assembled structure should be used, moved and kept in assembled state and not separated discretionally. The establishment of new standard for the assembled structure based on this study leads to the development of various types of temporary equipments using structural efficiency of prefabricated structure.

  • PDF

강원도 중소기업 품질경영 운영 방안 사례 (A study on Quality Management in Small and Medium Enterprises)

  • 박노국
    • 대한안전경영과학회지
    • /
    • 제8권1호
    • /
    • pp.131-144
    • /
    • 2006
  • Quality system management adapted by small and medium enterprises in Kangwon province to enhance the competitiveness was studied. Variance analysis on several questionnaire answers was performed. Motives for acquiring the accreditation, such as product export, adjustment to international trend, enhancement of brand/product recognition, CEO's mind change, and management innovation, have been changed significantly among business types. Mind changes after the accreditations were setting company's first priority on quality, enhanced recognition on compliance of in-house standards and regulations, employee's performance with the recognition of quality. Amongst service problems to maintain the ace reditations were difficulties in maintaining the recognition of the company's finality management, labor increase to maintain the ISO 9000 enforcement team, and financial burden to keep the accreditation. Quality recognition after the accreditations was significantly improved in setting company's first priority on quality, enhanced recognition on compliance of in-house standards and regulations, employee's performance with the recognition of quality.

공기호흡기용 타입 4 복합재료 용기 개발 (Development of a Type 4 Composite Cylinder for Self-contained Breathing Apparatus)

  • 조성민;김다은;성혜진;고영규;김홍철;이강옥;조민식;류성기
    • 한국기계가공학회지
    • /
    • 제18권12호
    • /
    • pp.1-6
    • /
    • 2019
  • Aluminum liners used in cylinders are hazardous for human health. In this study, we use a plastic PA liner inside cylinders to solve this problem. Plastic PA liners are widely used in the manufacturing industry in the production of food and beverage containers. We covered the aluminum boss with a plastic liner material and wound the composite fibers over the liner material. To reinforce the dome area, we used low strength / high elongation plastic liner. To predict the performance of the developed product, we conducted structural analyses utilizing the 3D laminated solid element. We verified the soundness of the product by testing the prototype.

중소기업의 혁신활동이 경영성과에 미치는 영향 (The Effect of Innovation on Business Performances in Small and Medium Enterprises)

  • 장광순;김용범
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.239-246
    • /
    • 2010
  • The purpose of this study is looking for the effects of innovation on business performance in Korean SMEs. We were able to obtain participations of 169 questionnaire, and derived statistics by means of SPSS/PC version 15.0 and AMOS. In this study we found that employee's quality mind and organizational supports for company innovation activities are significant to product innovation and process innovation. The reason is easy to adoption and participation in the innovation for all the members of the staff. As a statistical result, the research conduced that both product innovation and process innovation largely affects the business performances increase.

C-arm CT의 필수 성능평가 기준 마련을 위한 연구 (A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Development and validation of FRAT code for coated particle fuel failure analysis

  • Jian Li;Ding She;Lei Shi;Jun Sun
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4049-4061
    • /
    • 2022
  • TRISO-coated particle fuel is widely used in high temperature gas cooled reactors and other advanced reactors. The performance of coated fuel particle is one of the fundamental bases of reactor safety. The failure probability of coated fuel particle should be evaluated and determined through suitable fuel performance models and methods during normal and accident condition. In order to better facilitate the design of coated particle fuel, a new TRISO fuel performance code named FRAT (Fission product Release Analysis Tool) was developed. FRAT is designed to calculate internal gas pressure, mechanical stress and failure probability of a coated fuel particle. In this paper, FRAT was introduced and benchmarked against IAEA CRP-6 benchmark cases for coated particle failure analysis. FRAT's results agree well with benchmark values, showing the correctness and satisfactory applicability. This work helps to provide a foundation for the credible application of FRAT.

도로안전시설용 시선유도봉의 신뢰성 평가 (Reliability Assessment of Tubular Markers Used for Road Safety Facilities)

  • 구현진;윤예석
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권2호
    • /
    • pp.91-103
    • /
    • 2012
  • Tubular markers for road safety facilities are used to lead the driver's sight line and separate the lanes on the road. Such tubular markers are usually installed on the road and frequently hit by vehicles, they are accordingly requested to assure the product durability. The traditional evaluation method of tubular markers include only quality tests of the material properties. However, most of consuming agencies in charge of road management at fields have proposed problems on long-term performance of the products hit by vehicles under various weather conditions. Therefore, the objectives of this study are to develop the reliability test methods and equipments to simulate the product failures of tubular markers due to vehicle collision and wheel compression and the delamination and discoloration of reflection sheets attached on the surface of the products under high and low temperatures.

The G115 standardized ginseng extract: an example for safety, efficacy, and quality of an herbal medicine

  • Bilia, Anna R.;Bergonzi, Maria C.
    • Journal of Ginseng Research
    • /
    • 제44권2호
    • /
    • pp.179-193
    • /
    • 2020
  • Ginseng products on the market show high variability in their composition and overall quality. This becomes a challenge for both consumers and health-care professionals who are in search of high-quality, reliable ginseng products that have a proven safety and efficacy profile. The botanical extract standardization is of crucial importance in this context as it determines the reproducibility of the quality of the product that is essential for the evaluation of effectiveness and safety. This review focuses on the well-characterized and standardized ginseng extract, G115, which represents an excellent example of an herbal drug preparation with constant safety and efficacy within the herbal medicinal products. Over the many decades, extensive preclinical and clinical research has been conducted to evaluate the efficacy and safety of G115. In vitro and in vivo studies of G115 have shown pharmacological effects on physical performance, cognitive function, metabolism, and the immune system. Furthermore, a significant number of G115 clinical studies, most of them double-blind placebo-controlled, have reinforced the findings of preclinical evidence and proved the efficacy of this extract on blood glucose and lipid regulation, chronic obstructive pulmonary disease, energy, physical performance, and immune and cognitive functions. Clinical trials and 50 years of presence on the market are proof of a good safety profile of G115.