• Title/Summary/Keyword: Performance maintenance

Search Result 3,007, Processing Time 0.032 seconds

Mammary Performance of First Lactation Bali Cows (Bibos banteng) Fed Grass-Legume Based Diets in Relation to the Role of Glucose

  • Sukarini, I.A.M.;Sastradipradja, Djokowoerjo;Nusada, N.;Mahardika, I.G.;Kiranadi, B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.5
    • /
    • pp.615-623
    • /
    • 2001
  • A study of mammary function in relation to glucose metabolism of first lactation Bali cows on grass-legume diets was carried out using 12 primiparous cows (initial BW $263.79{\pm}21.66kg$) for 16 weeks starting immediately post calving. The animals were randomly allocated into 4 dietary treatment groups R1, R2, R3 and R4, receiving from the last 2 months of pregnancy onwards, rations based on a mixture of locally available grass and legume feed ad libitum. On a DM basis R1 contained 70% elephant grass (PP, Penicetum purpureum) plus 30% Gliricidia sepia leaves (GS), R2 was 30% PP plus 25% GS supplemented with 55% Hibiscus tilliacius leaves (HT, defaunating effect), R3 and R4 were 22.5% PP+41.25% GS+11.25% HT+25% concentrate, with R4 supplemented with zinc-diacetate. TDN, CP and zinc contents of the diets were 58.2%, 12.05% and 18.3 mg/kg respectively for R1, 65.05%, 16.9% and 25.6 mg/kg respectively for R2, 66.03%, 16.71% and 29.02 mg/kg respectively for R3 and 66.03%, 16.71% and 60.47 mg/kg respectively for R4. Milk production and body weights were monitored, an energy and protein balance trial conducted, overall glucose kinetics parameters assessed, mammary blood flow (MBF) and metabolite arteriovenous differences (${\Delta}AVs$) measured to get uptake data and mammary performance relationships. Parameters of glucose kinetics at peak lactation or during dry condition were not affected by ration quality. Glucose pool size, space of distribution and flux increased by 61.77, 62.26 and 82.08%, respectively, during lactation compared to the dry period. Mean glucose flux of lactating Bali cows was $5.52mg/min.kgBW^{0.807}$ which resembles the range of values of temperate dairy cows. Calculation showed that glucose requirements for maintenance, milk lactose and fat-glycerol synthesis, and the formation of NADPH reached 461.69 g for a yield of 1 kg/d or equal to 320.62 mg/min, which was less than the average glucose flux of lactating Bali cows of 481.35 mg/min. Mammary blood flow (MBF) values ranged from 56 to 83 l/h for the different treatments and the ratio MBF per kg milk produced improved from av. 1540 l/kg for R1 to av. 967 l/kg for R4 treated cows. Mammary glucose uptake ranged from 6.27 to 12.03 g/h or 120 to 140 g/kg milk. Glucose uptake was mass-wise 2 to 4 times the amount secreted as lactose, which indicated values less than the calculated mammary glucose needs and that little lactose was synthesized. The excess glucose taken-up was used for other metabolic processes. Linear relationships between metabolite ${\Delta}AVs$ and arterial blood plasma concentration [A] showed that in Bali cows triglycerides (TG), phenylalanine (Phe) and tyrosine (Tyr) have high coefficients of determination, i.e. 0.77, 0.81 and 0.69, respectively. For glucose, the relationship is quadratic with an $R^2$ value of 0.49. It was concluded that lactose synthesis was inadequate, which led to a speculation that milk yield could be improved by increased lactose synthesis.

Study on Importance-Performance Analysis Regarding Selection Attributes of Rice-Convenience Foods (쌀을 이용한 편의식품의 선택속성에 관한 중요도-수행도 분석(IPA))

  • Park, Hyojin;Oh, Narae;Jang, Jin-A;Yoon, Hei Ryeo;Cho, Mi Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.593-601
    • /
    • 2016
  • This study was carried out to establish an effective marketing strategy based on Importance-Performance Analysis (IPA) of rice-convenience foods. IPA is one of the most efficient and simple methods to evaluate product quality. Data were collected from 652 people (320 males and 332 females) and analyzed by SPSS 19.0. Subjects consumed rice-convenience foods as a snack substitute (19.3%), breakfast (20.7%), lunch (37.4%), dinner (15.2%), and late-night meal (7.4%). The purpose for consumption of rice-convenience foods were as follows: light meal (34.8%), lack of time to prepare meal (42.2%), favorite restaurant is not nearby (2.3%), save money (3.4%), and outdoor activities (9.7%). All attributes about rice-convenience foods were categorized into intrinsic property and extrinsic property. As a result of factor analysis, health, sensibility, and diversity factors were extracted from intrinsic property. In addition, dependence and appearance factors were drawn from extrinsic property. In analyzing the differences between importance and performance, there were significant differences; 16 items in the intrinsic property (P<0.01), and 10 items in the extrinsic property (P<0.001). The IPA matrix is composed of four quadrants, and each represents different strategies; the first, 'keep up the good work', the second, 'possible overkill', the third, 'low priority for management', and the fourth, 'concentrate management'. As a result, factors of rice-convenience foods positioned in the fourth quadrant were 'safety (from food additives, etc.)' and 'price' in the intrinsic property and 'nutrition label' and 'safety of packaging material' in the extrinsic property. They need to be improved immediately. In this study, rice-convenience food factors for continuous maintenance and concentrative improvement were compared by IPA. Based upon the results of this study, it is necessary to develop methods to make efficient use of limited resources and practical marketing strategies.

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.

A Tool Box to Evaluate the Phased Array Coil Performance Using Retrospective 3D Coil Modeling (3차원 코일 모델링을 통해 위상배열코일 성능을 평가하기 위한 프로그램)

  • Perez, Marlon;Hernandez, Daniel;Michel, Eric;Cho, Min Hyoung;Lee, Soo Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.107-119
    • /
    • 2014
  • Purpose : To efficiently evaluate phased array coil performance using a software tool box with which we can make visual comparison of the sensitivity of every coil element between the real experiment and EM simulation. Materials and Methods: We have developed a $C^{{+}{+}}$- and MATLAB-based software tool called Phased Array Coil Evaluator (PACE). PACE has the following functions: Building 3D models of the coil elements, importing the FDTD simulation results, and visualizing the coil sensitivity of each coil element on the ordinary Cartesian coordinate and the relative coil position coordinate. To build a 3D model of the phased array coil, we used an electromagnetic 3D tracker in a stylus form. After making the 3D model, we imported the 3D model into the FDTD electromagnetic field simulation tool. Results: An accurate comparison between the coil sensitivity simulation and real experiment on the tool box platform has been made through fine matching of the simulation and real experiment with aids of the 3D tracker. In the simulation and experiment, we used a 36-channel helmet-style phased array coil. At the 3D MRI data acquisition using the spoiled gradient echo sequence, we used the uniform cylindrical phantom that had the same geometry as the one in the FDTD simulation. In the tool box, we can conveniently choose the coil element of interest and we can compare the coil sensitivities element-by-element of the phased array coil. Conclusion: We expect the tool box can be greatly used for developing phased array coils of new geometry or for periodic maintenance of phased array coils in a more accurate and consistent manner.

The Situation and the Tasks of UK Rail Privatization, Focusing on after the Hatfield Accident (영국 철도 민영화의 현황 및 과제 (Hatfield사고 이후의 변화를 중심으로))

  • Lee, Yong-Sang
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.2 s.88
    • /
    • pp.91-100
    • /
    • 2006
  • This paper examines the situation and tasks of UK rail privatization, especially focusing on after the Hatfield rail accident. Earlier research which focused on the UK's Privatization had little knowledge of the explanations for recent changes. Moreover they had difficulty making a direct comparison between national rail and the privatized rail. Therefore we aye left without a good explanation which has a comprehensive perspective. I attempt to show the change in the rail privatization Process and its outcome, focusing on after the Hatfield rail accident. This Paper argues that the UK's vail privatization process has a regulatory framework which is too complicated with overlapping responsibilities that brought about inefficiency, increasing costs and a superficial safety regime. Especially the planning of rail and infrastructure maintenance did not come to play an appropriate role. However after 2000, the government took charge of setting the strategy for railways, and the Office of Rail Regulation covered safety performance and cost. explain that these changes present a good opportunity to solve the problem of passing the buck for poor performance. Through the analysis, I find that the passenger rail network is well-suited to deliver long distance business and commuters and that the subsidy from the government is decreasing. However, performance, for example punctuality and reliability. should be improved. Especially the Hatfield rail accident caused a reduction in the satisfaction of passengers. In future. the problems of rising costs and monopoly franchise system should be addressed.

A Study on Damage factor Analysis of Slope Anchor based on 3D Numerical Model Combining UAS Image and Terrestrial LiDAR (UAS 영상 및 지상 LiDAR 조합한 3D 수치모형 기반 비탈면 앵커의 손상인자 분석에 관한 연구)

  • Lee, Chul-Hee;Lee, Jong-Hyun;Kim, Dal-Joo;Kang, Joon-Oh;Kwon, Young-Hun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.7
    • /
    • pp.5-24
    • /
    • 2022
  • The current performance evaluation of slope anchors qualitatively determines the physical bonding between the anchor head and ground as well as cracks or breakage of the anchor head. However, such performance evaluation does not measure these primary factors quantitatively. Therefore, the time-dependent management of the anchors is almost impossible. This study is an evaluation of the 3D numerical model by SfM which combines UAS images with terrestrial LiDAR to collect numerical data on the damage factors. It also utilizes the data for the quantitative maintenance of the anchor system once it is installed on slopes. The UAS 3D model, which often shows relatively low precision in the z-coordinate for vertical objects such as slopes, is combined with terrestrial LiDAR scan data to improve the accuracy of the z-coordinate measurement. After validating the system, a field test is conducted with ten anchors installed on a slope with arbitrarily damaged heads. The damages (such as cracks, breakages, and rotational displacements) are detected and numerically evaluated through the orthogonal projection of the measurement system. The results show that the introduced system at the resolution of 8K can detect cracks less than 0.3 mm in any aperture with an error range of 0.05 mm. Also, the system can successfully detect the volume of the damaged part, showing that the maximum damage area of the anchor head was within 3% of the original design guideline. Originally, the ground adhesion to the anchor head, where the z-coordinate is highly relevant, was almost impossible to measure with the UAS 3D numerical model alone because of its blind spots. However, by applying the combined system, elevation differences between the anchor bottom and the irregular ground surface was identified so that the average value at 20 various locations was calculated for the ground adhesion. Additionally, rotation angle and displacement of the anchor head less than 1" were detected. From the observations, the validity of the 3D numerical model can obtain quantitative data on anchor damage. Such data collection can potentially create a database that could be used as a fundamental resource for quantitative anchor damage evaluation in the future.

On the Breeding of “CSR18${\times}$CSR19”- A Robust Bivoltine Hybrid of Silkworm, Bombyx mori L. for the Tropics

  • Kumar, N.Suresh;Basavaraja, H.K.;Kumar, C.M.Kishor;Reddy, N.Mal;Datta, R.K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.2
    • /
    • pp.153-162
    • /
    • 2002
  • Earlier breeding experiments undertaken at Central Sericultural Research and Training Institute, Mysore, India since a decade had resulted in the development of many productive and qualitatively superior bivoltine hybrids. However, the hot climatic conditions of tropics prevailing particularly in summer are not conducive to rear these high yielding bivoltine hybrids. This has necessitated breeding of compatible bivoltine hybrids for year-round rearing. Accordingly, the Japanese hybrid, B2Ol ${\times}$ BCS12 which was found to be tolerant to high temperature was used as breeding resource material. Following hybridization and selection rearing of silkworms was taken up in SERICATRON (Environmental chamber with precise and automatic control facilities for uniform maintenance of temperature and humidity) at high temperature of $36{\times}1^{\circ}C$ and 85${\times}$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65{\times}$5% RH. Directional selection was resorted to the batches reared at 36$\pm$1$^{\circ}C$ till F$_{5}$ keeping pupation rate as important selection criteria. From $F_{2}% onwards the experiment was modified in such a way as to conduct normal rearing every alternate generation to regain the lost vitality due to continuous exposure to high temperature and high humidity stress. At $F_{2}$ , Oval and dumb-bell cocoons were separated out and designated as CSR18 and CSR19, respectively. By utilizing these lines at $F_{12}$, the hybrid CSR18$\times$CSR19 was prepared and studied for the thermotolerance by subjecting to stress condition at high temperature of 36$\pm$1$^{\circ}C$ and 85$\pm$5% RH in fifth instar and the control batches at $25{\times}1^{\circ}C$ and 65${\times}$5% RH. The better performance of CSR18${\times}$CSR19 (survival > 88%) at $36{\times}1^{\circ}C$ clearly indicates the general superiority of CSR18${\times}$CSR19 with regard to high temperature tolerance over the productive hybrids and CSR18$\times$CSR19 can perform well in varied agro-climatic conditions of the tropics with optimum qualitative and quantitative characteristics.s.

An Experimental Study on Characteristics of Cooler by Oil Pressure for Decreasing Heat Load in Cold Storage (냉동창고 내 열부하 감소를 위한 유압 구동식 냉각기의 특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1116-1122
    • /
    • 2009
  • As a result of this study, we reached the following conclusions. With appropriate setting of oil pressure and flow rate, it operated same rotation speed with existing cooler by electrical transmission. In initial operation, a temperature of a cold storage is lower rapidly. As an internal temperature of a cold storage is lower, a decreasing rate of temperature is lower. As a result of comparing the both type, the cooler of oil pressure type showed the following results. The decreasing rate of temperature was more faster and shorter operating time was more shorter than existing cooler of electric type. The actual case of a cold storage, the cooler of oil pressure type can prevent quality deterioration and decrease power consumption. As an internal temperature of a cold storage is lower, power consumption increased rapidly, the oil pressure type showed lower power consumption. COP of two of these types decreased continuously as the internal temperature of a cold storage being reach setting temperature, and that of oil pressure type showed higher amount about 25%. As a setting temperature is lower, the number of refrigerator's operating times are less and operating time is longer, so power consumption is increased in the maintenance of a cold storage's internal temperature, power consumption of hydraulic type showed lower amount about 21~25% in two of these types.

The Application of an Algal Fence for the Reduction of Algal Intake into the Water Intake Facility (조류펜스의 조류 저감 효과에 대한 실험적인 평가)

  • Jang, Min-Ho;Park, Sung-Bae;Jung, Jong-Mun;Roh, Jae-Soon;정광석, Kwang-Seuk;Joo, Gea-Jae
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.4 s.105
    • /
    • pp.467-472
    • /
    • 2003
  • In this study, an algal fence was developed and applied to reduce the input of algal scum into the water intake facility. The effectiveness of vertical algal fences(overlapped three types of meshes, (312 ${\mu}m$ ${\times}$ 375 ${\mu}m$, 390 ${\mu}m$ ${\times}$ 450 ${\mu}m$, and 0,7 cm ${\times}$ 1cm; vertical depth, 1.5 m; length of fence, about 120 m)) was experimentally tested at a water intake facility (Mulgum, lower Nakdong River). The application of the fence resulted in the statistically significant difference of algal biomass between inside and outside of the fence. According to ANOVA test, chi. a concentration in Day-1showed large difference at each depth of 0, 1, 2 m (0.001> p at each depth, n = 16 respectively). Especially large difference was observed at 0 and 1 m depth. However, the fence was only effective for a short period and its efficiency declined by Day-5after the installation. When better maintenance options for the fence are prepared, e.g. mechanical installation and periodic backwashing of the fence, the performance of algal fence may be sustained. In addition, reliable models for bloom prediction are required to provide an advanced indication of the optimal timing for the installation so that effective operation would be achieved.

Distribution of vibration signals according to operating conditions of wind turbine (풍력발전기 운전환경에 따른 진동신호 분포)

  • Shin, Sung-Hwan;Kim, SangRyul;Seo, Yun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.192-201
    • /
    • 2016
  • Condition Monitoring System (CMS) has been used to detect unexpected faults of wind turbine caused by the abrupt change of circumstances or the aging of its mechanical part. In fact, it is a very hard work to do regular inspection for its maintenance because wind turbine is located on the mountaintop or sea. The purpose of this study is to find out distribution patterns of vibration signals measured from the main mechanical parts of wind turbine according to its operation condition. To this end, acceleration signals of main bearing, gearbox, generator, wind speed, rotational speed, etc were measured through the long period more than 2 years and trend analyses on each signal were conducted as a function of the rotational speed. In addition, correlation analysis among the signals was done to grasp the relation between mechanical parts. As a result, the vibrations were dependent on the rotational speed of main shaft and whether power was generated or not, and their distributions at a specific rotational speed could be approximated to Weibull distribution. It was also investigated that the vibration at main bearing was correlated with vibration at gearbox each other, whereas vibration at generator should be dealt with individually because of generating mechanism. These results can be used for improving performance of CMS that early detects the mechanical abnormality of wind turbine.