• 제목/요약/키워드: Performance and Efficiency Drop

검색결과 263건 처리시간 0.024초

미세먼지 필터 성능향상을 위한 primitive 구조의 유동 제어 연구 (Study on Flow Control of Primitive Structures for Enhancing Particulate Matter Filter Performance)

  • 이종배;황승현;김지연;김현;안동규;정성용
    • 소성∙가공
    • /
    • 제33권4호
    • /
    • pp.270-276
    • /
    • 2024
  • In order to improve the performance of the PM (Particulate Matter) filter, the TPMS structure was used as a flow controller to control the flow entering the filter. Among various TPMS structures, a primitive structure that is easy to utilize 3D printing technique was selected and the effect of unit cell size was analyzed. In addition, numerical analysis was performed and swirl ratio was analyzed to confirm changes in filter inlet flow characteristics that affect changes in filter performance. Unit cell size is closely related to filter performance, and both PM collection efficiency and pressure drop increase as unit cell size decreases. Through quality factor (QF) comparison, which comprehensively evaluate collection efficiency and pressure drop, it was confirmed that when the unit cell size is 5 mm, PM collection efficiency increases, but the flow controller actually reduces filter performance. QF values are similar for unit cell sizes of 10 and 20 mm, and it is advantageous to select the unit cell size among these two considering collection efficiency and operating costs. The filter's collection performance increases due to the increase in swirl flow caused by the primitive structure, and the filter's collection efficiency increases due to the swirl flow that increases throughout the flow field as the unit cell size becomes smaller.

방진 마스크 필터 교체와 성능 변화의 상관성 조사 (Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators)

  • 이헌용;박지훈;윤충식
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.

대용량의 가스상물질 처리를 위한 밸브트레이 (Valve Tray for Large Volume Gas Treatment)

  • 김재홍;김장호
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.61-65
    • /
    • 2001
  • To review mass transfer trays from a process of view, the dependence of efficiency in loading ranges and maximum loadings with an acceptable efficiency of traditional tray have to be known. It is reported about the performance of the metallic Dualflex, relatively new high performance packing. Absorption, desorption and rectification tests as well as pressure drop and maximum capacity are concerned, indicate the superiority of the Dualflex over the general packing of comparable, main process. The process engineering characteristics show that Dualflex can be applied for all mass transfer precesses and it is to be recommended especially for those high capacity separations which requite allow low pressure drop because of the thermal sensibility of the product or because of the need of energy saving.

  • PDF

이산화탄소 냉매 시스템용 내부 열교환기의 냉방성능에 관한 실험적 연구 (Experimental Study on Cooling Performance of Internal Heat Exchanger for CO2 Refrigerant System)

  • 김대훈;권영철
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.587-592
    • /
    • 2008
  • 이산화탄소 냉매 시스템용 내부 열교환기의 성능을 조사하기 위하여 4종류의 내부 열교환기를 사용하여 냉방운전조건에서 실험을 수행하였다. 내부 열교환기의 길이, 관 개수, 운전조건, 형상 변화에 대한 영향이 연구되었다. 내부 열교환기 길이가 증가할수록 능력과 효율은 향상되었다. 압력강하는 고압측보다 저압측에서 더 크게 나타났다. 가스쿨러의 온도가 높아질수록 능력과 효율은 선형적으로 증가하였으며, 증발기의 운전조건은 과열도보다는 이상영역을 설정하면 효율증대 효과 측면에서 유리하였다. 마이크로 채널의 경우가 튜브보다 능력과 효율이 크게 우수하였지만 압력강하 측면에서는 크게 불리하였다.

Effect of Inlet Clearance Gap on the Performance of an Industrial Centrifugal Blower with Parallel Wall Volute

  • Hariharan, Chinnasamy;Govardhan, Mukka
    • International Journal of Fluid Machinery and Systems
    • /
    • 제6권3호
    • /
    • pp.113-120
    • /
    • 2013
  • While performing numerical simulations, it is general industrial practice to neglect the clearance gap between the impeller and the inlet duct. In the present work, the effect of clearance gap on the performance of an industrial sized centrifugal blower is simulated for two volutes of width ratios and various flow coefficients. The results show that the clearance has a positive effect at low mass flow rates. This is observed in the pressure rise (1.3%) as well as in efficiency (0.7%). At higher mass flow rates, it has a negative effect with a drop in efficiency of 1% and pressure drop of about 1.4%. The effect of clearance gap on volute with higher width ratio is smaller when compared with the volute with smaller width ratio.

조사후시험시설에서의 핫셀 배기포집시스템의 성능평가 (Performance of the Exhaust Filtration System of Hot Cell at PIEF)

  • 황용화
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

이동통신 기지국 직접대기냉각용 에어필터의 성능평가실험 (An Experiment on Performance Evaluation of a Direct Ambient Cooling Air Filter for Wireless Telecommunication Base Transceiver Stations)

  • 여국현;유경훈;차호진;김용우;최동규;이홍규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.436-441
    • /
    • 2006
  • In recent European telecommunication base transceiver stations(BTS) a membrane laminated air filter is reported to replace a heat exchanger in order to cool internal digital units of BTS. The concept of using the air filter is for the direct ambient cooling(DAC) of BTSs without heat loss generally found ill the heat exchanger type BTS. In the present study, a performance evaluation experiment was conducted to investigate the pressure drop characteristics with dust loading and the particle collection efficiency of the air filter for the DAC of BTS.

  • PDF

반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화 (System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System)

  • 이종건;이현규;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제48권1호
    • /
    • pp.43-53
    • /
    • 2020
  • 프리스월 노즐과 리시버 홀의 상대적 위치가 반경방향 분사방식 프리스월 시스템의 성능에 미치는 영향을 분석하였다. 본 연구에서는 5개의 프리스월 노즐 위치와 4개의 리시버 홀 위치 조합을 통해 20개의 설계점에 대한 분석을 진행하여 유량계수와 온도 강하 효율 변화 경향성을 연구하였다. 시스템 유량계수는 프리스월 노즐의 압력비와 비슷한 경향을 보였다. 캐비티 내부의 유동이 벽면의 영향을 크게 받을수록 시스템 성능 변화가 발생하였으며 회전면보다 정지면의 영향력이 더 큰 것을 확인하였다. 형상변수 변화에 따라 기준 설계점 대비 유량계수는 -1.39%~1.25%, 온도강하효율은 -5.41%~2.94% 변화하였다.

수소 충전 시스템용 리셉터클의 내부 압력 분포와 압력 강하에 관한 수치적 연구 (A Numerical Analysis of Pressure Distribution and Pressure Drop in Receptacle for Hydrogen Charging System)

  • 왕위엔강;이승혁;손채훈;이세동;이현복
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.497-504
    • /
    • 2023
  • This study analyzes pressure distribution and pressure drop in the receptacle used in charging system of hydrogen fuel cell vehicles. The objective is to minimize receptacle-induced pressure drop by redesigning internal flow channels. Through numerical simulations, three receptacle variants are compared with a baseline case. Results show reduced pressure drop in the filter section. However, the check valve section exhibits higher pressure drop, requiring further improvement. By increasing throat diameter, pressure drop is decreased by 28% between inlet and outlet of the receptacle. This study shows the relationship between dynamic pressure and pressure drop, providing a guideline for receptacle performance optimization. The redesigned receptacle offers potential for enhancing hydrogen charging efficiency.

변환효율 향상을 위한 횡방향 가변 셀밀도법을 사용한 자동차용 촉매변환기의 수치적 설계 (Numerical Design of Auto-Catalyst Substrate for Improved Conversion Performance Using Radially Variable Cell Density)

  • 정수진;김우승
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1596-1607
    • /
    • 2000
  • The optimal design of auto-catalyst needs a good compromise between the pressure drop and flow uniformity in the substrate. One of the effective methods to achieve this goal is to use the concept of radially variable cell density. But this method has not been examined its usefulness in terms of chemical behavior and conversion performance. In this work, two-dimensional performance prediction of catalyst coupled with turbulent reacting flow simulation has been used to evaluated the benefits of this method n the flow uniformity and conversion efficiency. The results showed that two cell combination of 93cpsc and 62 cpsc was the most effective for improved pressure drop and conversion efficiency due to balanced space velocity and efficient usage of geometric surface area of channels. It was also found that large temperature difference between the bricks in case that the edge of the frontal face of brick has too much lower cell density(less than 67% of cell density of the center of the brick). This study has also demonstrated that the present computational results show the better prediction accuracy in terms of CO, HC and NO conversion efficiencies compared to those of conventional 1-D adiabatic model by comparison with experimental results.