• 제목/요약/키워드: Performance amplification

검색결과 268건 처리시간 0.032초

Cyclic testing of a new visco-plastic damper subjected to harmonic and quasi-static loading

  • Modhej, Ahmad;Zahrai, Seyed Mehdi
    • Structural Engineering and Mechanics
    • /
    • 제81권3호
    • /
    • pp.317-333
    • /
    • 2022
  • Visco-Plastic Damper (VPD) as a passive energy dissipation device with dual behavior has been recently numerically studied. It consists of two bent steel plates and segments with a viscoelastic solid material in between, combining and improving characteristics of both displacement-dependent and velocity-dependent devices. In order to trust the performance of VPD, for the 1st time this paper experimentally investigates prototype damper behavior under a wide range of frequency and amplitude of dynamic loading. A high-axial damping rubber is innovatively proposed as the viscoelastic layer designed to withstand large axial strains and dissipate energy accordingly. Test results confirmed all assumptions about VPD. The behavior of VPD subjected to low levels of excitation is elastic while with increasing levels of excitation, a significant source of energy dissipation is provided through the yielding of the steel elements in addition to the viscoelastic energy dissipation. The results showed energy dissipation of 99.35 kN.m under a dynamic displacement with 14.095 mm amplitude and 0.333 Hz frequency. Lateral displacement at the middle of the device was created with an amplification factor obtained ranging from 2.108 to 3.242 in the rubber block. Therefore, the energy dissipation of viscoelastic material of VPD was calculated 18.6 times that of the ordinary viscoelastic damper.

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

바닥충격음 차단을 위한 뜬바닥 구조의 진동응답특성에 관한 실험적 연구 (An Experimental Study on the Vibration Response Characteristics of Floating Floor Systems for Heavyweight Impact Noise Reduction.)

  • 최경석;석원균;목지욱;신이섭;김형준;김정진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.227-228
    • /
    • 2023
  • A floating floor generally consists of mortar bed separated from the structural RC slab by a continuous resilient layer. It is known that the floating floors are a type of vibration-isolation system to improve the impact sound insulation performance. However, some researchers have demonstrated that the amplification of vibration response at a specific range of frequencies results in an increase in the impact sound level. This study carried out the forced vibration tests to obtain the frequency response function (FRF) of a floating floor compared with a bare RC slab. Test results shows that the additional peak occur in vibrational spectrum of the floating floor except natural vibration modes of the bare RC slab. This is because the relatively flexible resilient material and mass of the mortar bed offer an additional degree of freedom in the structural system. Therefore, it could be efficient for reduction of floor impact vibration and noise to control the additional mode frequency and response of floating floors.

  • PDF

국내 지진관측기록의 P파를 이용한 지진현장경보기술 적용 (Application of the Onsite EEW Technology Using the P-Wave of Seismic Records in Korea)

  • 이호준;전인찬;서정범;이진구
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.133-143
    • /
    • 2020
  • 연구목적: 본 연구는 국내에서 발생한 지진관측기록의 P파 성분으로부터 PGV를 예측하기 위한 예측식을 도출하고 지진현장경보(Onsite EEW)신뢰성을 검증함을 목적으로 한다. 연구방법: 국내에서 발생한 627개 지진 이벤트에 대한 관측기록으로부터 P파 외의 잡음을 제거하여 기반암에서의 PGV와의 예측식을 도출하고, 이를 이용한 지진현장경보 시뮬레이션을 통해 PGV의 예측치와 관측치 비교로부터 신뢰성을 검증한다. 연구결과: P파 잡음을 제거한 지진 관측기록으로부터 Filter Picker를 사용하여 P파를 추출하고, PGV와의 회귀분석을 통해 지진현장경보를 위한 예측식을 도출했다. 현장경보 시뮬레이션 결과 경보대상 구간인 MMI IV 이상 구간에서 MMI±1 오차범위 내 80%의 성공률을 얻었다. 결론: 본 연구를 통해 국내 지진기록을 이용한 지진현장경보의 설계 가능성과 성능을 확인하였다. 유효성을 높이기 위해, 해외 지진다발지역의 중규모지진의 관측기록을 분석기록으로 추가하고, 오탐지 제어 및 지표에서의 지진파 증폭에 효과 구현이 필요하다.

레인지후드 덕트설치 조건에 따른 소음 및 풍량특성 연구 (A Study on the Performance of Noise Level and Airflow Amount of a Kitchen Hood by the Different Conditions of Airflow Path.)

  • 김일호;김윤재;이용준;이규동
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.11-14
    • /
    • 2007
  • Noise level and Airflow amount of a kitchen hood are affected by the conditions of airflow path. Thus this study is expected to be used as a basic reference in designing airflow path of apartment housing throughout analysing changes in noise level and airflow amount from the various conditions of airflow path. Noise level generated by the kitchen hood is estimated in a kitchen and a living room of two constructed apartment houses, and an experiment is conducted in an half anechoic chamber to analyze noise level and airflow amount by the different length, diameter and number of windings of a round shaped soft duct which is connected to the kitchen hood. The measured results in apartment houses show that the noise level in both apartments exceeds the NC standard greatly in living spaces. In apartment A, a regular apartment house, the noise level was $NC-65{\sim}75$, $NC-45{\sim}60$ and NC-70, NC-45 in the kitchen and living room with an operation of kitchen hood in 1 and 3 stages. In apartment B, an apartment complex, the noise level was NC-55 and NC-60 in the kitchen and living room with an operation of kitchen hood in 3 stages. In particular, there was an increase of noise level at 125Hz-band resulted from an amplification of sound, which requires adequate measures in noise reduction. The results measured in Half anechoic chamber show 99% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 100mm to ${\Phi}$ 125mm, 37% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ 125mm to ${\Phi}$ 150mm, and 173% of airflow amount increase with the modification of a duct' s diameter from ${\Phi}$ l00mm to ${\Phi}$ 150mm. The noise level was lower than the level measured in apartment housing about 20 in NC-value and 11.4 in dB(A)-value, which was interpreted as the effect of the load by the pressure condition at the rear end of the duct. Also, an amplification of sound in 125Hz-band influenced NC-value considerably, therefore effective measure is needed.

  • PDF

육회와 육사시미에 접종된 Salmonella Typhimurium와 Listeria monocytogenes 검출을 위한 Loop-mediated isothermal amplification와 식품공전의 배지 시험법, real-time PCR의 검출 성능 비교 (Comparison of Loop-mediated Isothermal Amplification and Korea Standard Food Codex (KFSC) Method for Detection of Salmonella Typhimurium, Listeria monocytogenes Artificially Inoculated in Yuk-hwe and Yuk-sashimi)

  • 곽승해;이소영;김진희;오세욱
    • 한국식품위생안전성학회지
    • /
    • 제34권3호
    • /
    • pp.277-282
    • /
    • 2019
  • 본 연구에서는 한국 전통 식품에서 Salmonella Typhimurium와 Listeria monocytogenes의 검출에 대하여 LAMP에 기반한 3M Molecular Detection Assay 2 (3M MDA 2)와 식품공전에 등재된 분리배지, real-time PCR의 검출 성능을 비교하고자 하였다. 육회와 육사시미에 $10^0-10^4CFU/25g$의 수준으로 S. Typhimurium와 L. monocytogenes을 각각 접종하였다. Citrobacter freundii와 Listeria innocua는 S. Typhimurium와 L. monocytogene의 검출에 영향을 주는 균으로 사용하였다. S. Typhimurium와 L. monocytogenes만 $10^0-10^4CFU/25g$ 수준으로 접종한 모든 시료에서는 분리배지, real-time PCR과 LAMP에서 양성으로 검출되었다. C. freundii와 L. innocua를 같이 접종한 경우에서 부분적으로 양성이 나타났다. 육회와 육사시미에 대하여 real-time PCR 보다 3M MDA 2가 더 검출효율이 높음을 알 수 있었다. 분리배지가 가장 검출효율이 높았지만 3M MDA 2와 큰 차이가 없었다. 배지를 사용하는 방법은 최소 일주일의 시간이 소요되고 PCR의 경우 inhibitor의 영향을 많이 받아 정확한 검출이 어려운 점이 있다. 그러나 LAMP에 기반한 3M MDA 2는 enrichment 후 다음 날 간단한 protocol을 통해 25분 이내로 샘플의 양성 반응을 확인할 수 있어 식중독균에 대해 신속하고 정확한 검출이 가능한 것으로 판단되었다.

블록체인 네트워크 기반의 도메인 네임 시스템 설계 및 구현 (Design and Implementation of Blockchain Network Based on Domain Name System)

  • 허재욱;김정호;전문석
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.36-46
    • /
    • 2019
  • 인터넷에 연결된 호스트의 개수가 대폭 증가해 1984년 도메인 네임 시스템(Domain Name System, 이하 DNS)이 도입되었다. DNS는 웹 사이트를 검색할 때, 일련의 숫자로 이루어진 복잡한 IP 주소를 외우지 않고 편리성이 높은 문자 형태의 주소를 사용할 수 있게 함으로써 현재 인터넷을 이용하는 모든 사용자에게 중요한 핵심 요소로 사용되고 있다. 그러나 이러한 DNS의 중요성에 비해 권한 할당 문제, 공인 등록 관련 분쟁, DNS 캐시 포이즈닝(DNS Cache Poisoning), DNS 스푸핑(DNS Spoofing), 중간자 공격(Man-in-the-Middle Attack), DNS 증폭 공격(DNS Amplification Attack)과 같은 각종 보안 취약점, 초연결 네트워크 시대의 더 많은 도메인 네임의 필요성 등 많은 문제점이 존재한다. 본 연구에서는 기존의 DNS가 가지는 이러한 문제점을 효과적으로 개선하고자 분산원장기술인 블록체인을 이용해 DNS를 구현하는 법을 제안하고, 이더리움 기반의 플랫폼을 이용해 구현하였다. 추가적으로 기존의 도메인 네임 등록 및 도메인 네임 서버의 정성적 성능 비교 평가를 하고, 제안하는 시스템이 기존 DNS의 보안 문제점을 개선할 수 있는지 보안 평가를 하였다. 결론적으로 블록체인을 이용해 더 안전하고 효율적으로 DNS 서비스를 제공할 수 있다는 것을 보였다.

고감도 보급형 방사선 측정센서 모듈 개발 (Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module)

  • 오승진;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.510-514
    • /
    • 2022
  • 본 논문에서는 고감도 보급형 방사선 측정센서 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 섬광체+광증배소자(SiPM) 센서 최적화 구조설계, 센서 드라이버용 증폭과 필터 및 제어회로 설계, 근거리 통신을 포함한 제어회로 설계, 센서 기구설계 및 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 섬광체+광증배소자(SiPM) 센서 최적화 구조 설계는 센서 구조 설계를 위한 섬광체와 광증배소자(SiPM)의 특성을 확인하여 설계한다. 센서 드라이버용 증폭과 필터 및 제어회로 설계는 SiPM을 이용하여 섬광체로 방사선에 의해 발생하는 미세 섬광신호를 처리하도록 설계한다. 근거리 통신을 포함한 제어회로 설계는 근거리 무선통신 기능을 지원하기 위한 MCU 설계 및 유선 통신 지원을 통해 데이터 전송이 가능하도록 설계를 수행한다. 센서 기구설계 및 제작은 플라스틱 섬광체에서 발생한 미세 섬광 신호를 광증배소자(SiPM)에 전달하기 위해 플라스틱 섬광체 외부에 반사지(미러링)를 감싸 발생한 섬광이 반사되어 효율을 높이도록 설계한다. 시제품에 적용되는 GUI 개발은 각 화면에 따라 상단에 날짜와 시간을 표현하며, 측정단위 및 시간, 초, 알람 레벨, 통신상태, 배터리 용량 등이 표현되도록 한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선량 측정 범위가 30𝜇Sv/h ~ 10mSv/h로 측정되어서, 현재 국내외에서 상용으로 판매되는 제품들 중에서 최고수준 범위와 같은 결과가 산출되었다. 또한, ±7.4%의 측정 불확도가 측정되어서 국제 표준인 ±15% 이하에서 정상동작 됨이 확인되었다

공간 GIS 기반의 지반 정보 시스템 구축을 통한 대전 지역의 부지 응답에 따른 지진재해 구역화 (Seismic Zonation on Site Responses in Daejeon by Building Geotechnical Information System Based on Spatial GIS Framework)

  • 선창국
    • 한국지반공학회논문집
    • /
    • 제25권1호
    • /
    • pp.5-19
    • /
    • 2009
  • 지진으로 인한 지반 재해의 대부분은 토사 두께나 기반암 심도 그리고 토사 강성과 같은 국부적 지질 조건에 따라 크게 영향을 받는 지반 운동 증폭과 관련된 부지 효과로 인해 발생되어 왔다. 본 연구에서는 지반 자료에 관한 통합적 GIS-기반의 정보 시스템인 지반 정보 시스템(GTIS)이 국내 연구 개발의 거점 도시인 대진 지역에서의 지진 유발 재해에 대한 지역적 종합 대책 수립의 일환으로 구축되었다. 관심 대상 영역에 대한 지반 정보 시스템 구축을 위하여, 연구 대상 영역을 포함하는 확장 영역에 대해 기존 지반공학 관련 자료 수집이 이루어 졌고 지표 지반-지식 자료의 확보를 위한 부지 방문 조사가 추가적으로 수행되었다. 관심 대상 영역의 부지 효과 평가를 위한 실질적 적용 목적으로 부지 주기에 관한 지진재해 구역지도를 작성하고 지진 유발 재해 예측을 위한 지역적 종합 대책으로 제시하였다. 또한, 연구 대상 영역 내 임의 부지에서의 내진 설계 및 내진 성능 평가를 위한 부지 증폭계수의 결정 수단으로 부지 주기의 공간 분포 따른 부지 분류의 지진재해 구역화를 수행하였다. 본 연구에서 수행된 대전 지역에서의 지진재해 구역화로부터 GIS 기반의 지반 정보 시스템이 지진재해의 지역적 예측 뿐만 아니라 지진재해 저감을 위한 의사 결정에서의 높은 유용성을 확인하였다.

Reliability of mortar filling layer void length in in-service ballastless track-bridge system of HSR

  • Binbin He;Sheng Wen;Yulin Feng;Lizhong Jiang;Wangbao Zhou
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.91-102
    • /
    • 2023
  • To study the evaluation standard and control limit of mortar filling layer void length, in this paper, the train sub-model was developed by MATLAB and the track-bridge sub-model considering the mortar filling layer void was established by ANSYS. The two sub-models were assembled into a train-track-bridge coupling dynamic model through the wheel-rail contact relationship, and the validity was corroborated by the coupling dynamic model with the literature model. Considering the randomness of fastening stiffness, mortar elastic modulus, length of mortar filling layer void, and pier settlement, the test points were designed by the Box-Behnken method based on Design-Expert software. The coupled dynamic model was calculated, and the support vector regression (SVR) nonlinear mapping model of the wheel-rail system was established. The learning, prediction, and verification were carried out. Finally, the reliable probability of the amplification coefficient distribution of the response index of the train and structure in different ranges was obtained based on the SVR nonlinear mapping model and Latin hypercube sampling method. The limit of the length of the mortar filling layer void was, thus, obtained. The results show that the SVR nonlinear mapping model developed in this paper has a high fitting accuracy of 0.993, and the computational efficiency is significantly improved by 99.86%. It can be used to calculate the dynamic response of the wheel-rail system. The length of the mortar filling layer void significantly affects the wheel-rail vertical force, wheel weight load reduction ratio, rail vertical displacement, and track plate vertical displacement. The dynamic response of the track structure has a more significant effect on the limit value of the length of the mortar filling layer void than the dynamic response of the vehicle, and the rail vertical displacement is the most obvious. At 250 km/h - 350 km/h train running speed, the limit values of grade I, II, and III of the lengths of the mortar filling layer void are 3.932 m, 4.337 m, and 4.766 m, respectively. The results can provide some reference for the long-term service performance reliability of the ballastless track-bridge system of HRS.